ML Accessories Knightsbridge EX001T Скачать руководство пользователя страница 3

EX001T 

 

 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following product

:

 

EX001T 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this product is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is Class II double insulated  

 

This product is IPX2 rated 

INSTALLATION 

Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the 

manufacturer of the sensors that they are compatible. 

 

Provide power to the required point of installation  

 

Cut a suitable 100mm diameter hole in the mounting surface ensuring not to infringe with any joists, 

gas / water pipes or electrical cables. Install suitable ducting and a suitable external grille or shutter. 

The maximum length of ducting to be used is 2m 

 

Remove the faceplate by inserting a flat head screwdriver and carefully prising apart  

 

Mark the location of the fixing holes and drill ensuring not to infringe with any gas / water pipes or 

electrical cables  

 

If required, carefully remove the cable knock-out on the rear of the baseplate and guide the mains 

cable through. Alternatively, the cable can be surface mounted via the cut-out on the bottom of the 

product. If surface mounted, the cable must be secured under the cable clamp provided 

 

Fix the base to the mounting surface using the fixings provided 

 

Ensuring correct polarity is observed, wire as shown in Fig. 2 

 

Fig. 2            

 

IPX2 

3

•  Adjust the overrun timer with the aid of a small screwdriver. Turn anti-clockwise to reduce (to a minimum 

of 2 minutes) and clockwise to increase (to a maximum of 30 minutes)

• Click the front cover back into place
• Switch on and check for correct operation

WARNING

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 
testing. Irreparable damage will occur if this instruction is not followed.

GENERAL

This product should be recycled in the correct manner when it reaches the end of its life. Check local 
authorities for where facilities exist. 
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the 
product.

Fig. 2

WARRANTY

This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance 
with the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch 
code will invalidate the warranty. If this product should fail within its warranty period, it should be returned 
to the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility for 
any installation costs associated with the replacement product. Your statutory rights are not affected.  
ML Accessories reserve the right to alter product specification without prior notice.