Cut-out with sleeve

Cut-out without sleeve

70mm

65mm

Fig. 1

• Please note this product is supplied with a sleeve for direct mounting in the ground. The sleeve is not 

necessary for installation into decking

• We recommend not installing in areas where there is a high risk of flooding or areas where water may sit on 

top of the fitting (see Fig. 2)

• Ensure a minimum of 300mm of drainage is put below the luminaire (see Fig. 2)

INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following product:  

CAPWGU

 

SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this product

 

is fitted) does not exceed the rating of 

the circuit cable, fuse, or circuit breaker 

 

This product is safe for use as a drive-over fitting 1000kg @ 5mph (with half-lip cover removed) 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product should be installed in the upright position 

 

This product is Class I and must be earthed 

 

This product is IP65 rated 

INSTALLATION 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods). 

Suitable IP rated junction boxes should be used where required 

 

The power source connections should be local and accessible via a suitable IP rated enclosure 

 

Cut a suitable hole in the mounting surface as per the cut-out details (see Fig.1) ensuring not to 

infringe with any joists, gas/water pipes or electrical cables  

 

Cut-out with sleeve 

Cut-out without sleeve 

70mm 

65mm 

Fig. 1 

 

Please note this product is supplied with a sleeve for direct mounting in the ground. The sleeve is not 

necessary for installation into decking 

 

We recommend not installing in areas where there is a high risk of flooding or areas where water may 

sit on top of the fitting (see Fig. 2) 

 

Ensure a minimum of 300mm of drainage is put below the luminaire (see Fig. 2) 

 

 

Fig. 2 

 

There must be enough cable below the luminaire to carry out maintenance work (see Fig. 3) 

Fig. 2

• There must be enough cable below the luminaire to carry out maintenance work (see Fig. 3)