• Please note this product is supplied with a sleeve for direct mounting in the ground. The sleeve is not
necessary for installation into decking
• We recommend not installing in areas where there is a high risk of flooding or areas where water may sit on
top of the fitting (see Fig. 2)
• Ensure a minimum of 300mm of drainage is put below the luminaire (see Fig. 2)
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following product:
CAPWGU
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this product
is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
•
This product is safe for use as a drive-over fitting 1000kg @ 5mph (with half-lip cover removed)
•
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•
This product should be installed in the upright position
•
This product is Class I and must be earthed
•
This product is IP65 rated
INSTALLATION
•
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•
The power source connections should be local and accessible via a suitable IP rated enclosure
•
Cut a suitable hole in the mounting surface as per the cut-out details (see Fig.1) ensuring not to
infringe with any joists, gas/water pipes or electrical cables
Cut-out with sleeve
Cut-out without sleeve
70mm
65mm
Fig. 1
•
Please note this product is supplied with a sleeve for direct mounting in the ground. The sleeve is not
necessary for installation into decking
•
We recommend not installing in areas where there is a high risk of flooding or areas where water may
sit on top of the fitting (see Fig. 2)
•
Ensure a minimum of 300mm of drainage is put below the luminaire (see Fig. 2)
Fig. 2
•
There must be enough cable below the luminaire to carry out maintenance work (see Fig. 3)