  File: SG524_r3eng - April 2017 - Technical note: SG 524                                                                                                                        page   1  of  16

PM 250 

        SG 524

CE Declaration of Conformity

Dichiarazione di Conformità CE

Manufacturer’s Name: 

 

 

 

Mks Instruments Italy s.r.l

Nome del Costruttore:

Manufacturer’s Address:    

Via Curie, 8 - 42122 Reggio Emilia - Italy

Indirizzo del Costruttore:

Declare that the microwave generator: 

 

 

 

 

Dichiara che il Prodotto:

 

product name: 

 

SG 524 Microwave Generator

 

nome del prodotto 

SG524 Generatore di microonde

 
 

model: 

  SG524E.xxx2, 

SG524E.xxx1 

    

 

The product described above is in conformity with the provision of the following European Directives:
Il prodotto sopra descritto è in conformità con le seguenti Direttive Europee:

 

2014/35/UE 

Harmonization of the laws of the member States relating to electrical equipment designed for use within  

 

   certain 

voltage 

limits

   

Riavvicinamento delle legislazioni degli Stati membri relative al materiale elettrico destinato ad essere  

 

 

 

 

adoperato entro taluni limiti di tensione

 

2014/30/UE 

Harmonization of the laws of the member States relating to electromagnetic compatibility

   

Riavvicinamento delle legislazioni degli Stati membri relative alla compatibilità elettromagnetica

     
Conformity to the Directives is assured through the application of the following standards:

La conformità alle Direttve è assicurata tramite l’applicazione dei seguenti standards:

 

Reference number       Edition        

Description

 

Numero di riferim       Edizione     

Descrizione

 
 

EN61010-1 

     2011-03    

Safety requirements for electrical equipment for measurement, control and laboratory use

     

Prescrizioni di sicurezza per apparecchi elettrici di misura, controllo e per uso in laboratorio

 

EN61000-6-4 

     2007-11     

Electromagnetic compatibility - Generic emission standard, industrial environment

     

Compatibilità elettromagnetica - Norma generica sull’ emissione, ambiente industriale

    
 EN61000-6-2

 

 

     2006-10     

Electromagnetic compatibility - Generic immunity standard, industrial environment

 

 

 

 

 

Compatibilità elettromagnetica - Norma generica sull’ immunità, ambiente industriale

 

EN61000-4-3  

    2007-04 

Electromagnetic compatibility - Testing & measuring technique: RF immunity test

 

 

 

 

 

Compatibilità elettromagnetica - Tecnica di prova e misura: immunità ai campi irradiati

 

 

EN61000-4-6 

     2006-10     

Electromagnetic comp. - Testing & measuring technique: immunity to conducted disturbance

 

 

 

 

 

Compatibilità elettromagnetica - Tecnica di prova e misura: immunità disturbi  condotti RF 

    

Reggio 

Emilia, 

April 

2017 

          

 

 

 

 

 

 

 

 

                                 Marco Garuti - 

Gen Manager

 

Содержание SG 524

Страница 1: ...SOLID STATE MICROWAVE GENERATOR 450 W 2450 MHZ TECHNICAL NOTE issue April 2017 SG 524...

Страница 2: ...Cover Rear...

Страница 3: ...i membri relative alla compatibilit elettromagnetica Conformity to the Directives is assured through the application of the following standards La conformit alle Direttve assicurata tramite l applicaz...

Страница 4: ...tion alone must be included into a larger process equipment and it s for stationary use Nevertheless we invite the User to respect the following Directive rules this WEEE is not a municipal waste and...

Страница 5: ...Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement With reference to Basic Standard EN55011 this equipment i...

Страница 6: ...lay version with front panel manual commands and PLC interface to control by I O it carries also one USB standard port which allows to drive read data from the unit with a simple software like our Fro...

Страница 7: ...f 9 450 Adjustable range 2 100 Max value differs at frequency band limit Output linearity Wrf 5 Forward power Displayed value vs monitor signal Output stability 1 For input fluctuations within 10 Outp...

Страница 8: ...your external contactor Once switched OFF wait at least two seconds before setting it ON again The OFF state between two consecutive ON state must last two seconds minimum The following description is...

Страница 9: ...LINE BREAKER 0 1 in pos 1 the unit goes in POWER ON The line switch can be freely switched off at any time POWER SET it s an analog input value and has the meaning of desired percent of the full outp...

Страница 10: ...u generate a directory named program_name containing the micro code to be loaded an executable program named SendApplicationProgram bat and the loader sRecLoad exe Once unpacked the zip program enter...

Страница 11: ...generator was running before entering into autotune mode The user may adjust the various parameters via three buttons and a rotating knob on the front panel as follows ESC button used to return back t...

Страница 12: ...n case of heavy standing wave the generator may be overloaded with the sum of both forward and reverse power and parts of the circuit on the final power combiner as well as the coaxial socket may be d...

Страница 13: ...84810 1 Preferred size other length on request max 2 m Coax Cable 7 8 with 7 16 Plugs l 1m 441384811 1 Other length on request max 4 m 3 Transition 7 16 to WR340 MWR26 COAX7 16L Aluminum construction...

Страница 14: ...gnals in the range 0 10Vdc pin 2 and pin 3 ground on pin 15 and 16 respectively Forward and Reverse Power Monitor CONN 2 LOCATION Forward Power Wrf 1 Vmon 45 W Pin no 2 return on pin 15 Reverse Power...

Страница 15: ...for the protocol implemented Each SG 524 generator must be associated to an address the two digital rotating switches must be used the left switch sets the tens the right sets the units Depending fro...

Страница 16: ...1 1 Plug for CONN 1 included on Plug Set MOCPC03 3 1 Connector Sub D type 25 pin female CONN 2 4 1 AC DC power supply 120 240V 32 V out PLRSP200032 5 1 Anybus CC interface Profibus Modbus PLAB62xxx S...

Страница 17: ...alarm persist contact the service 0100 Internal Safety Relay Malfunction The internal safety relay could have been damaged i e by a shortcircuit on the contact Try to restart the unit If the alarm per...

Страница 18: ...ET524 contains plugs for Conn 1 and 5 only Coax Plug right angle 7 16 M F p n MWCOAX7 16L Coax cable length 1 m 1 2 p n 441384810 1M0 Same as above 2 m p n 441384810 2M0 Cable set for input line and s...