647C
3. Functionality
17
3.4 The PRESSURE CONTROL menu
MGC 647C V3.0
CH1 CH2 CH3 CH4
0.000 1.750 1.400 0.000
CH5 CH6 CH7 CH8
0.000 0.000 0.000 0.000
GAIN 01.00 PRESSURE UNIT
INTEG 02.00 Torr
LEAD 00.30 0.3501
SETPOINT MODE
PCS 0.467 OFF
0.3500
00 ERRORS FLOW ON INPUT DIRECT
Figure 8
The PRESSURE CONTROL menu displays the actual flows and the actual pressure with its unit.
During an application with an external pressure controller, the corrective action is also shown in
PCS (
P
ressure
C
ontrol
S
ignal).
The pressure is controllable through the pressure setpoint and the two pressure modes:
OFF
- set point for pressure regulation is turned off.
AUTO
- set point for pressure regulation is turned on.
All parameters are edited as usual.