22
TX-3
OPERATION
2.
3.
4.
5.
Move the Table (F) toward the front of the Saw so that the Blade does not interfere with the Table when
setting up the Cutting Head.
To perform miter cuts, loosen the Miter Adjustment Knob (J) and lift Air Flow Module (K) with the Air Flow
Module Handle (M) located in the rear of the Upper Air Flow Module (K).
Tilt Motor Assembly (L) to desired degree using the Miter Index (E).
Tighten Miter Adjustment Knob (J) to hold Motor Assembly (L) in position.
E
G
F
MITER CUTS
1. The Table (F) has 45º (G), 22.5º (H) and 90º (I) clearance slots built-in. 90º and 45º are pre-set at the factory.
22.5º miter can be obtained by aligning the Pointer to 22.5 mark on the Miter Index (E). All other angular
cuts can be obtained by raising the work up. Make sure the Blade will clear the Table before operations.
M
H I
K
J
L