MOTOR SPECS
EXTENSION CORD LENGTH
Motor
Voltage
Amps
25'
50'
100'
200’
160107
230V 1 Ph
23
14 ga
12 ga
8 ga
6 ga
MK-DDG SERIES SAFETY
WARNING
• Locate the length of extension cord needed in table provided.
• Once the proper length is found, move down the column to obtain the correct AWG size required
for that length of extension cord. For example, a fifty foot extension cord would require an AWG
size of 14 for a 120V volt circuit.
Use of undersize extension cords result in low voltage to the motor that can result in motor burnout and
premature failure. MK Diamond warns that equipment returned to us showing signs of being run in a
low voltage condition, through the use of undersized extension cords will be repaired or replaced totally
at the customers expense. There will be no warranty claim.
To choose the proper extension cord,