MK Diamond Products MK-100 TRACKER Скачать руководство пользователя страница 7

 

MK-100 TRACKER 

Revision 02/03, Effective Date February 12, 2003 

 

Page 7

SAFETY 

 

ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS: 

 

In order to prevent potential electrical shock and injury, the following electrical safety precautions and symbols 
should be followed at all times! 
 
 

In case of a malfunction or breakdown, grounding provides a path of least resistance for electric 
current to reduce the risk of electric shock.  This tool is equipped with an electric cord having an 
equipment-grounding conductor and a grounding plug.  The plug must be plugged into a matching 
outlet that is properly installed and grounded in accordance with all local codes and ordinances. 

• 

Do not modify the plug provided – if it will not fit the outlet; have the proper outlet installed by a 
qualified electrician 

• 

Improper connections of the equipment-grounding conductor can result in a risk of electric shock.  
The equipment-grounding conductor is the insulated conductor that has an outer surface that is 
green, with or without yellow stripes.  If repair or replacement of the electric cord or plug is 
necessary, do not connect the equipment-grounding conductor to a live terminal 

• 

Check with a qualified electrician or service personnel if the grounding instructions are not 
completely understood, or if in doubt as to whether the tool is properly grounded 

• 

Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that 
accept the tool's plug 

• 

Repair or replace a damaged or worn cord immediately 

 

 
 

This tool is intended for use on a circuit that has an outlet that looks like the one shown in Sketch A 
of Figure 1.  The tool has a grounding plug that looks like the plug illustrated in Sketch A of FIGURE 
1.  A temporary adapter, which looks like the adapter illustrated in sketches B and C, may be used to 

 
 

Connect this plug to a 2-pole receptacle as shown in Sketch B, if a 
properly grounded outlet is not available.  The temporary adapter 
should be used only until a properly grounded outlet can be 
installed by a qualified electrician.  The green-colored rigid ear, 
lug, and the like, extending from the adapter, must be connected 
to a permanent ground such as a properly grounded outlet box. 

 

 
 

NOTE:  Use of a temporary adapter is not permitted in Canada. 

 
 
 
 

 
 

 
To reduce the risk of electrocution, keep all connections dry and off the ground. 
 
A Ground Fault Circuit Interrupter (GFCI) should be provided on the circuit(s) or outlet(s) to be used 
for the Tile Saw.  Receptacles are available having built-in GFCI protections and may be used for 
this measure of safety. 
 
When using an extension cord, the GFCI should be installed closest to the power source, followed 
by the extension cord and lastly, the saw. 
 

 

Metal Screw 

Cover of Grounded 

Outlet Box 

(A) 

(B) 

(C) 

(D) 

ADAPTER 

Grounding 

Means 

Grounding 
Pin 

Grounding 

Pin 

FIGURE 1 

Содержание MK-100 TRACKER

Страница 1: ...S MANUAL OPERATING INSTRUCTIONS Enter the Serial Number of your new saw in the space below The Serial Number is located on the left side of the blade guard NOTE For your 1 one year warranty to be effe...

Страница 2: ...tly your MK 100 TRACKER should provide you with years of quality service In order to help you we have included this manual This owner s manual contains information necessary to operate and maintain yo...

Страница 3: ...ct Specifications 10 UNPACKING TRANSPORT UNIVERSAL STAND and ASSEMBLY Unpacking 11 Contents 11 Transport 11 Universal Stand 12 Assembly 13 SETUP ADJUSTMENT AND OPERATION Setup 16 Adjustment and Operat...

Страница 4: ...being used Each message will be preceded by the word NOTE as in the example below NOTE Equipment and or property damage may result if these instructions are not followed GENERAL SAFETY PRECAUTIONS AN...

Страница 5: ...est performance Always follow maintenance instructions for lubricating and when changing accessories DISCONNECT TOOLS Power tools should always be disconnected before servicing or when changing access...

Страница 6: ...910 1200 Diamond Blades improperly used are dangerous Comply with American National Standards Institute Safety Code B7 1 and Occupational Safety and Health Act covering Speed Safety Guards Flanges Mou...

Страница 7: ...r the tool is properly grounded Use only 3 wire extension cords that have 3 prong grounding plugs and 3 pole receptacles that accept the tool s plug Repair or replace a damaged or worn cord immediatel...

Страница 8: ...Do not use damaged extension cords Examine extension cords before using and replace if damaged Do not abuse extension cords and do not yank on any cord to disconnect Keep cords away from heat and sha...

Страница 9: ...nterrupt 155678 1B Motor Rear Caution Receptacle for Pump Only 154822 1C Motor Rear Service or Warranty Information 155038 2 Blade Guard Serial Number 157249 01 3A Motor Front Warning Read and Follow...

Страница 10: ...e half 3 1 2 inches thick in one pass Motor Specifications Motor specifications for the MK 100 TRACKER are listed in Table 2 below Voltage 115 v Overall Amperage 13 4 a Motor Only Amperage 12 8 a Freq...

Страница 11: ...1 owners manual one 1 pump manual and one 1 warranty card MK 100 TRACKER Frame and Water Basin MK 100 TRACKER Cutting Head Removable Cutting Table Diamond Blade Adjustable Cutting Guide Electric Wate...

Страница 12: ...en the Universal Stand and place on flat surface B Remove Water Basin C Orient the Saw to the Stand D Seat Left Post Side of saw onto stand between stand Orientation Pin E Seat Right Side of saw onto...

Страница 13: ...Shaft Post Turn Clockwise to tighten A Position Movable Cutting Table to the front of the saw and raise the Blade Guard C Depress and hold the Shaft Lock pushbutton and remove Retaining Screw and Out...

Страница 14: ...to the Blade Guard Retaining Hole Thumbscrew Splash Guard Turn clockwise To tighten A Align the four 4 wheels of the Movable Cutting Table to the saw Guide Rails B Seat all four 4 wheels onto the Guid...

Страница 15: ...5 Water Pump Preparation Cooling Transfer Tube Turn clockwise to tighten Discharge Fitting Press on Flow Adjusting Clamp Press on A Install Water Pump Discharge Fitting B Press one end of the Cooling...

Страница 16: ...ch is in the OFF position B Verify the Movable Cutting Table moves freely C Inspect the Diamond Blade for damage verify the blade is correct for the material being cut D Inspect the Pump Assembly for...

Страница 17: ...ation method the water should be changed often for longer pump life A Remove the Drain plug B Place the Water Pump In an external container C Fill the external container until water completely covers...

Страница 18: ...length will cause the motor to overheat and could cause premature failure 5 Use an approved Ground Fault Circuit Interrupter GFCI 6 Do not cover the motor vents as this could lead to motor overheating...

Страница 19: ...t length indicated inside the diamond C Tighten the retaining thumbscrew D Place the tile against the Ruler Stop and Cutting Guide E Turn the motor ON F Verify proper cooling flow on both sides of the...

Страница 20: ...se to loosen Ruler Stop Adjustable Cutting Guide E Turn the motor ON F Verify proper cooling flow on both sides of the blade See Maintenance Section to increase decrease flow Off Position ON OFF Switc...

Страница 21: ...tting Guide E Turn the motor ON F Verify proper cooling flow on both sides of the blade See Maintenance Section to increase decrease flow Off Position H Turn the motor OFF when work is complete B Plac...

Страница 22: ...w ON OFF Switch A Remove the Adjustable Cutting Guide Turn counter clockwise to loosen Ruler Stop Adjustable Cutting Guide E Turn the motor ON F Verify proper cooling flow on both sides of the blade S...

Страница 23: ...F Switch B Unplug the GFCI from the power source F Install the Adjusting Knob D Remove the Cutting Head from The rear pivot hole E Install the Cutting Head onto the front pivot hole G Set cutting dept...

Страница 24: ...Unplug the GFCI from the power source D Remove the Cutting Head See Adjusting the Cutting Head C Remove Water Basin E Loosen the Post Support Plate and retaining bolts F Remove the Post Support Plate...

Страница 25: ...Switch is in the OFF position Off Position ON OFF Switch F Unplug MK 100 TRACKER from the GFCI E Unplug the GFCI from the Power source B Place the Water Pump In an external container A Clean the Water...

Страница 26: ...otor casing when cleaning K Clean the Movable Cutting Table Roller Wheel Frame Support J Clean the Movable Cutting Table Guide Bar L Clean the remainder of the MK 100 TRACKER Roller Wheel Frame Suppor...

Страница 27: ...MK 100 TRACKER the following procedure should be performed after each use Lubricate all points listed below with light oils such as 3 in 1 WD 40 etc A Check and adjust V belt tension Following 1st 48...

Страница 28: ...unter clockwise to loosen D Verify the Roller Wheel Assembly is tight and in good condition F Verify the Motor Adjustment Strap is tight E Verify all motor mounting Bolts are tight B Lubricate the Out...

Страница 29: ...Cutting Head Adjustment Knob I Remove the Cutting Head See Adjusting the Cutting Head L Lubricate the Cutting Head Pivot Shaft K Lubricate the Cutting Head Adjustment Knob retaining holes D Increase c...

Страница 30: ...ade can be dressed using the MK Dressing Stick part number 152972 and by following the steps below C Position the Dressing Stick A Setup the MK100 for operation See Setup Adjustment and Operation F Cu...

Страница 31: ...to tighten A Locate the Shaft Lock pushbutton on the underside of the Cutting Head Cutting Head Shaft Lock Pushbutton Retaining Nut and Outer Flange Rotate Blade Wrench counter clockwise to loosen B R...

Страница 32: ...ng Head I Loosen the Motor Adjustment Strap H Loosen motor mounting bolts If re tensioning only go to step N G Check belt for proper tension if tension correct go to step R proper tension 1 8 inch F I...

Страница 33: ...ighten the Motor Adjustment Strap to remove slack O Check V belt tension proper tension 1 8 inch P Repeat steps N and O until proper V belt tension is achieved Q Tighten the motor mounting bolts R Ins...

Страница 34: ...o MK Diamond for Repair E Return to MK Diamond If not Glazed go to Step B Contact place of purchase or MK Diamond 800 421 5830 to verify blade If Glazed Dress Blade See Blade Dressing If not Glazed go...

Страница 35: ...me Retaining Screw C Loosen the back Frame Retaining Screw Allen Screw Allen Wrench Rotate counter clockwise to loosen D Loosen the front Frame Allen Screw Frame Cutting Table Blade Cutting Groove E A...

Страница 36: ...and check for restriction check Impeller damage G Remove the 3 Pump Casing Retaining Screws F Remove the Pump Intake Screen and check for debris Go to Step C Check Impeller for damage If flow exist go...

Страница 37: ...ng the rod out through each of the cooling flow tubes located on the underside o the Blade Guard The cooling channels should be rodded until all ports are free of foreign debris J Remove the Cooling C...

Страница 38: ...cuit Interrupter GFCI is tripped E Verify circuit breaker is not tripped if it is tripped reset the circuit breaker once Return to MK Diamond for Repair G Return to MK Diamond If less than 20 Amps mov...

Страница 39: ...MK 100 TRACKER Revision 02 03 Effective Date February 12 2003 Page 39 EXPLODED VIEW AND PARTS LIST EXPLODED VIEW...

Страница 40: ...Carton 1 154022 A16 Card MK Warranty Registration 1 155037 A17 Label Do Not Return 1 157063 A18 Sell Sheet Tile Accessory 1 156915 B Carton n a B1 Carton 100 1 158541 B2 Insert Carton Cutting Head 2 1...

Страница 41: ...Serial No Mark 1 157249 01 H Subassembly 115V Cutting Head MK 100 1 158191 H1 Head 10 Cutting comp Head 10 Cutting raw 1 1 158224 158223 H2 Pin Blade Shaft Lock 1 158200 H3 Spring Blade Guard Lock 1 1...

Страница 42: ...asher Head Grounding 1 158209 J18 Washer 10 Internal Tooth Lock 2 158336 J19 Tie 12 X 10 Clamp 1 158210 J20 Screw 10 32 X 1 Socket Head Set Cup Point 1 158254 J21 Nut 10 32 Hex 2 156269 J22 Washer 1 2...

Страница 43: ...ype of blade to use depends on The requirements of the job The machine tool utilizing the diamond blade The preference of the operator In the case of DRY cutting the overwhelming popularity and quanti...

Страница 44: ...R DESCRIPTION 1 137166 MK 200 10 x 5 8 Arbor 2 128074 MK 215 10 x 5 8 Arbor 3 153252 MK 315 10 x 5 8 Arbor 4 134577 Dual 45 Flat Angle Guide 5 134585 small or 153201 large 45 Bullnose Miter 6 134569 9...

Страница 45: ...ious twelve 12 months Have the Model Number of the saw Have the Serial Number of the saw Have the location of where the saw was purchased Have the date when the saw was purchased Contact Customer Serv...

Страница 46: ...cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from bricks and cement and other masonry products and Arsenic and c...

Отзывы: