assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in 

the  middle.  Therefore, the first  fixture  controlled by the  controller  could be the last  fixture  in the  chain.  When a 

fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, 

no matter where it is located in the DMX chain. 

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation):

 The Inno Pocket Spot Pearl 

can be controlled via DMX-512 protocol. The Inno Pocket Spot Pearl two DMX channel modes; 9 channel mode & 

11 channel mode. The DMX address is set electronically using the controls on the front panel of the unit. Your unit 

and your DMX controller require a approved DMX-512 110 Ohm Data cable for data input and data output (Figure 

1). We recommend Accu Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 

Ohm  shielded  cable  (This  cable  may  be  purchased  at  almost  all  professional  sound  and 

lighting  stores).  Your 

cables should be made with a male and female XLR connector on either end of the cable. Also remember that 

DMX cable must be daisy chained and cannot be split. 

 

Notice: 

Be sure to follow figures two and three  when making your own cables. Do  not  use the  ground lug on the 

XLR  connector.  Do  not  connect  the  cable’s  shield  conductor  to  the  ground  lug  or  allow  the  shield  conductor  to 
come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior. 

 

Special Note: Line Termination. 

When longer runs of cable are used, you may need to use a terminator on 

the  last  unit  to  avoid  erratic  behavior.  A  terminator  is  a  110-120  ohm  1/4  watt  resistor  which  is  connected 

between  pins  2  and  3  of  a  male  XLR  connector  (DATA  +  and  DATA  -).  This  unit  is  inserted  in  the  female 

XLR  connector  of  the  last  unit  in  your  daisy  chain  to  terminate  the  line.  Using  a  cable  terminator  (MJ  part 

number Z-DMX/T) will decrease the possibilities of erratic behavior.

 

 

Содержание MJ-1025

Страница 1: ...ket Spot Pearl MJ 1025 INSTRUCTION MANUAL Thank you for choosing our LED mini spot moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Страница 2: ...the separation condition Every unit is tested completely and packed properly by the manufacturer Please make sure the packing and the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer or dealer Attention Unceasingly carries o...

Страница 3: ...ge and frequency of power supply match the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cab...

Страница 4: ...ion yourself The installation should be checked by a skilled person once a year The Inno Pocket Spot Pearl is fully operational in two different mounting positions hanging upside down from a ceiling or set on a flat level surface To avoid internal damage to the unit never mount the unit on its side as illustrated above Be sure this fixture is kept at least 0 5m away from any flammable materials de...

Страница 5: ...nywhere DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals locate...

Страница 6: ... making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Notice Be sure to follow figures two and three when making your own cables Do not ...

Страница 7: ...ransmission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line When inserting standard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion System Menu DMX 512 Address setting Channel Mode Show Mode Dimmer Mode ...

Страница 8: ...MENU button for at least 3 seconds To exit without making any adjustments press the MENU button The display will lock after 30 seconds press the MENU button for 3 seconds to unlock ADDR DMX Address Setting 1 Press the either the MENU UP or DOWN buttons until ADDR is displayed press ENTER 2 The current address will now be displayed and flashing Press the UP or DOWN buttons to find your desired addr...

Страница 9: ...mer curve and press ENTER to confirm and exit SLND This will let you set unit as a master or slave in a master slave configuration 1 Press the MENU button until SLND is displayed press ENTER Either MAST SL 1 or SL 2 will be displayed 2 Press the UP or DOWN buttons until your desired setting is displayed press ENTER to confirm NOTE In a Master Slave configuration you can set one fixture to Master a...

Страница 10: ...ch to have the LED display switch off after 10 seconds 3 Press ENTER to confirm To make you LED display reappear again press any button DISP This function will reverse the display 180º 1 Press the MENU button until DISP is displayed press ENTER 2 Press ENTER to flip the display Press ENTER to flip it again Press ENTER when you have made your desired setup TEST This function will run a self test pr...

Страница 11: ...ton for one second to exit OCOL adjustment for the color wheel 1 Press the ENTER button for at least 3 seconds then press the UP or DOWN buttons so that OCOL is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Operation Universal DMX Control This function allows you to use a Elation universal D...

Страница 12: ... unit can act as a Master or as a Slave 1 Using approved DMX data cables daisy chain your units together via the XLR connector on the rear of the units Remember the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only For longer cable runs ...

Страница 13: ...d this button the unit will begin to strobe COLOR Press this button to enter Dimmer mode Use the 1 9 buttons to select your desired color Adjust the output intensity using the DIMMER and DIMMER buttons 1 9 When in either Gobo mode or Color mode these buttons will allow you to select either a gobo or color SOUND ON OFF These buttons activate and deactivate the sound active mode SHOW This activates ...

Страница 14: ... 240 247 248 255 Close Open Strobe Slow Fast Open Fast Close Slow Open Open Fast Open Slow Close Open Random Strobe Open 6 8 CH Dimmer 000 255 0 100 7 9 CH Pan Tilt Speed 000 255 Fast Slow 8 CH 10 CH Function 000 069 070 079 080 089 090 099 100 109 110 119 120 199 200 209 210 249 250 255 Null Blackout while Pan Tilt Move Null Blackout when Color changes Null Blackout when Gobo changes Null Reset A...

Страница 15: ... dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates I e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp output 1 Use normal glass cleaner and a soft cloth to wip...

Страница 16: ... may not activate the unit Specifications Model MJ 1025 Voltage 100 240V 50 60Hz LED 1 x 12W White LED Power Consumption 26W 120V 27W 230V Dimensions 6 25 L x 5 75 W x 10 5 H 159mm x 147mm x 265mm Weight 7 Lbs 3 kgs Beam Angle 13 Degrees Fuse 3 Amp Duty Cycle None DMX 2 DMX Channel Modes 9 Channel Mode 11 Channel Mode Colors 7 White Gobos 7 Spot Sound Active Yes Working Position Any Safe Secure Po...

Отзывы: