OPERATION
4. Mode 3
Mode 3 Operation Example
Function Operation
Printout
Power ON
POWER
* DP-1VR *
* MODE 3*
DATE 2000/ 2/ 2
TIME 13: 35
Subgroup measurement start
Transition to subgroup measurement
mode
TOL.LIMIT
SUB GR. NO.1
Data fetching (subgroup measurement
mode)
DATA
DATA
DATA
Data is fetched from the
measuring device and printed
out.
1 12.00 mm
2 26.25 mm
3 32.56 mm
Data cancellation
Cancels the data input immediately
before.
([CL] key operation before subgroup
measurement)
CE
* CANCEL *
Subgroup data all clear
Clears all the data in the subgroup and
performs measurement again from No.
1 data ([CL] key operation during
subgroup measurement)
CL
* CLEAR SUB DATA*
Time print
PRINTER ON/OFF +
DATA
DATE 2000/ 2/ 2
TIME 13: 35
Ends subgroup measurement and
performs X-R calculation for subgroup.
(Subgroup measurement mode normal
end)
STAT
X 0.92335 mm
R 2.77568 mm
PART NO.
DATE 2000/ 2/ 2
TIME 13: 35
NAME
Stops subgroup measurement and
cancels the subgroup measurement
mode. (Subgroup measurement mode
forced end)
TOL.LIMIT
_
_
* EXIT SUB GR. *
Performs next subgroup measurement.
TOL.LIMIT
SUB GR. 2