background image

– 32 –

At the end of the season

At the beginning of the season

Stop the unit and turn off the power source.

The unit consumes approx. 4W even when the unit is not operating. 
Turning off the power source will help saving energy consumption and cost.

Ensure that the earth wiring is not snapped nor 
disconnected.

Make sure that there are no obstacles blocking 
the airflow around the air intake and outlet 
openings of the indoor and outdoor units.

NOTE

Cooling/heating is affected by an air filter clogged up with dust etc., and the operation noise becomes louder. It 
may also use extra electricity. Please clean the air filter at appropriate intervals.

1

2

Remove batteries from the remote control.

Clean both the indoor and outdoor units.

Clean and reinstall the air filters.

Perform the fan operation for 2 to 3 hours.

Dry the inside of the unit.

3
4
5

Make sure that there is no corrosion or rust on 
the base frame of the outdoor unit.

Insert batteries in the remote control.

Turn on the power source.

3

2

1

4

5

Installing, inspecting and replacing the air-cleaning filter

1. Open the air inlet panel and remove the air filters. 

 Page 30

2. Remove the allergen clear filter (Light orange) from air-conditioner and inspect the 

filter. Use a vacuum cleaner to remove any dust or dirt from the allergen clear filter. 
Replace the allergen clear filter if it cannot be cleaned or if it has been for about 
1 year.
(The allergen clear filter should be replaced after about 1 year of used. However, the 
actual replacement period may vary depending on the conditions in which the filter 
is used.)

Remove the photocatalytic washable deodorizing filter (orange) from air-conditioner 
and inspect the filter. Periodically, remove any dust or dirt from the photocatalytic 
washable deodorizing filter. If the photocatalytic washable deodorizing filter is 
particularly dirty, it may be washed with water. However, the filter is fragile, so do 
not scrub it with excessive force. After washing the filter, place it in sunlight to dry. 
Placing the filter in sunlight restores the deodorizing effect.

3. Install the air-cleaning filter in the air-conditioner.

NOTE

  The allergen clear filter and the photocatalytic washable deodorizing filter 

may be installed on either the right or left side of the air-conditioner.

  Install the allergen clear filter with the light orange side on front side.

  The heat exchanger may injure your fingers. 

  Stand firmly on a stepladder or other stable object when removing the air inlet panel and filters.

 Item 

Feature 

Color

For replacing the air-cleaning filter, contact your dealer.

The power of enzyme is used to eliminate allergy-
causing allergens that accumulate on the filter.

Sources of odors on the filter are broken up, resulting in 
a deodorizing effect.

Photocatalytic washable 
deodorizing filter

Orange

Allergen clear filter

Light orange

 CAUTION

4. Install the air filters and close the air inlet panel. 

 Page 30

Air-cleaning filter

Panel 
(air-conditioner)

RLF012A204_EN_1-36.indd   32

RLF012A204_EN_1-36.indd   32

7/29/2017   6:11:41 PM

7/29/2017   6:11:41 PM

Содержание SRK20ZSXA-W

Страница 1: ...RLF012A204_EN_1 36 indd 1 7 29 2017 6 11 36 PM RLF012A204A SRK20ZSXA W SRK25ZSXA W SRK35ZSXA W SRK50ZSXA W SRK60ZSXA W USER S MANUAL AIR CONDITIONER...

Страница 2: ...04 Please dispose of batteries correctly at your local community waste collection or the recycling center Safety precautions 2 Tips for effective operation 6 Name of each part and its function 7 Remot...

Страница 3: ...installation manual There is information included in the user s manual and or installation manual Following precaution is only for R32 This equipment uses flammable refrigerants If the refrigerant is...

Страница 4: ...erly so that all the water is drained out Improper installation may lead to water drop in the room resulting in wet furniture Make sure that the system has been properly earthed Earth wire should neve...

Страница 5: ...you may get injured Do not place a flammable insecticide or paint spray near the air conditioner nor spray it directly on the system This may result in a fire Do not expose any combustion appliance di...

Страница 6: ...cause accidents due to oxygen deficiency Stand firmly on a stepladder or other stable object when removing the inlet panel and filters Failure to observe this may result in injury through insecure obj...

Страница 7: ...s inhaled excessively it may cause deterioration of nerve function like dizziness and headache or deterioration of heart function like irregular heartbeat and heart palpitation temporarily If refriger...

Страница 8: ...ire Drain hose Drain hole IT MIGHT CAUSE INJURY DO NOT STEP ON TOP OF THIS UNIT WARNING DO NOT INSERT ANYTHING INTO THE AIR OUTLET IT MIGHT CAUSE INJURY DO NOT TOUCH THE ALUMINUM FINS IT MIGHT CAUSE I...

Страница 9: ...reen blue Accessories Illuminates during operation green except ECO operation blue ECO operation Blinks slowly when SELF CLEAN operation 3 seconds ON 1 second OFF Blinks when airflow is stopped to pre...

Страница 10: ...ning note for remote control Are the batteries running down Setting the batteries above Replace the batteries with new ones and retry the operation Operation failure with the remote control If the ope...

Страница 11: ...nit At completion of the setting the indoor unit emits a buzzer sound peep If no reception sound is emitted start the setting from the beginning again Setting an indoor unit 1 2 3 Since the signal is...

Страница 12: ...econds of setting the airflow range while the airflow range setting display illuminates The diagram below indicates the airflow ranges corresponding to the air conditioner s installation location Cons...

Страница 13: ...onditioner When the room temperature is 30 C or higher When there is any obstacle such as furniture or a glass window between the air conditioner and the person s When the person s is covering most of...

Страница 14: ...EFT RIGHT button This button changes the airflow left right direction SILENT button This button sets the SILENT operation OFF TIMER button This button selects OFF TIMER operation WEEKLY button This bu...

Страница 15: ...or the ACL switch is pressed the remote control will be set to the initial state Since the WEEKLY TIMER program is not set in the initial state set the program according to the setting procedure Exam...

Страница 16: ...18 When 18 is indicated even if the button is pressed the indicator does not change Press the button When it is a little cold Press the button When it is a little hot FAN SPEED The FAN SPEED can be s...

Страница 17: ...frost over which prevents efficient heating If this happens the automatic defrost function is activated and the heating operation stops for 5 to 15 minutes during defrosting Both indoor and outdoor f...

Страница 18: ...ion starts the flap and louver direction is fixed at the horizontal center position in order to avoid cold draft It returns to the set position when the warm air supply is started The flap and louver...

Страница 19: ...rned off start the operation from Step 1 With the air conditioner running start from Step 2 Example You prefer it to stop 22 30 Press the ON OFF button Press the OFF TIMER button OFF TIMER display is...

Страница 20: ...0 20 Units of ten minutes 1 00 1 10 Every time the button is pressed the display is switched in the order of 0 00 23 50 23 40 Units of ten minutes 23 00 22 50 Set at 8 00 Press the SET button The dis...

Страница 21: ...tion Stop Operation starts Check the room temp 1 hour before Set time When SLEEP TIMER is selected the set temperature is automatically adjusted after a while ensuring that the room is not too cold du...

Страница 22: ...splay is also switched to the operation contents that are set The setting can be changed from the remote control after ON TIMER operation of the WEEKLY TIMER The following contents can be set by the O...

Страница 23: ...ton is pressed the display is switched in the order of 3 Press the SET button The day of the week is determined and the program number blinks Press the PROGRAM button and current day of the week blink...

Страница 24: ...e button is pressed the display is switched in the order of 0 00 23 50 23 40 Units of ten minutes 23 00 22 50 When ON TIMER is selected go to Step 8 When OFF TIMER is selected go to Step 9 Setting mod...

Страница 25: ...P4 Tue Sun P1 P2 P3 P4 P1 P2 P3 P4 Display of all of the days of the week Press the or TIMER button Select a day of the week and a program number to be confirmed Display starts from the current day of...

Страница 26: ...while the air conditioner is OFF NOTE It will go into ECO operation at the next time the air conditioner runs in the following case 1 When the air conditioner is stopped by ON OFF button during ECO o...

Страница 27: ...ure Press the SILENT button to turn off the SILENT display During SILENT operation the maximum cooling and heating capacities deteriorate SILENT operation will not function during DRY and FAN operatio...

Страница 28: ...he brightness level by pressing or TIMER button Display brightness adjustment This function can be used when it is necessary to adjust the brightness of unit display Select the display brightness adju...

Страница 29: ...topped the operation resumes with the same settings The operation does not resume even if a person is detected after 12 hours has elapsed The RUN light blinks slowly during standby It is recommended t...

Страница 30: ...after HEAT FAN OFF TIMER SLEEP and ALLERGEN CLEAR operations have finished The indoor unit fan runs for about two hours in SELF CLEAN operation The RUN light illuminates during SELF CLEAN operation Pr...

Страница 31: ...water 1 2 3 Reinstall the air filter Hold firmly the filter at both sides as shown at right and insert securely Operating without the air filters will make the unit dusty and may cause damage Cleaning...

Страница 32: ...ectrical motor Improper handling by hand will cause mechanical damage and effect to open close operation Do not close air inlet panel forcibly Outer panel is to be closed automatically when power sour...

Страница 33: ...hould be replaced after about 1 year of used However the actual replacement period may vary depending on the conditions in which the filter is used Remove the photocatalytic washable deodorizing filte...

Страница 34: ...lation and functioning Do not install the unit in any of the following places Where there is a danger of leaking flammable gases Where there is substantial splashing of oil Malfunctioning due to corro...

Страница 35: ...start is blocked for 3 minutes after you have stopped the operation to protect the unit The 3 minutes protection timer in the microcomputer automatically starts it up again Some steam releases during...

Страница 36: ...remote control operation switch is in the AUTO mode the air conditioner automatically selects either COOL or HEAT mode when operation is started depending on the room temperature During simultaneous o...

Страница 37: ...oor temperature sensor error Outdoor heat exchanger sensor error Discharge pipe sensor error Suction pipe sensor error Broken outdoor sensor wire poor connector connection Broken heat exchanger sensor...

Страница 38: ...SYSTEMS LTD 16 5 Konan 2 chome Minato ku Tokyo 108 8215 Japan http www mhi mth co jp en MITSUBISHI HEAVY INDUSTRIES AIR CONDITIONERS AUSTRALIA PTY LTD 9C Commercial Road Kingsgrove NSW 2208 PO BOX 318...

Отзывы: