127
-
'16 • SCM-T-199
5. TABLE OF INDOOR UNIT COMBINATIONS
●
The combinations of the indoor units is indicated by numbers. They are read as follows.
(Example) SRK20ZMX-S → 20 SRK25ZMX-S → 25
●
The capacity of the indoor units is shown by rooms. If this exceeds the maximum capacity of the outdoor unit, the demand
capacity will be proportionally distributed.
●
If units are to be combined, use the table below to make the proper selection.
・
Number of connectable indoor units
SCM40ZS-S,45ZS-S
SCM50ZS-S
2
2
2
3
MIN
MAX
Indoor unit
combination
Cooling capacity (kW)
Power consumption (W)
Standard current (A)
Indoor unit
capacity (kW)
Total capacity (kW)
Min.
Standard
Max.
220V
230V
240V
A
B
Min.
Standard
Max.
1
unit
20
2.0
-
1.5
2.0
2.8
560
590
880
2.9
2.8
2.7
25
2.5
-
1.5
2.5
3.4
560
670
1040
3.3
3.2
3.1
35
3.5
-
1.5
3.5
3.9
560
970
1200
4.8
4.6
4.4
2
units
20 + 20
2.00
2.00
3.0
4.0
5.7
600
840
1750
4.2
4.0
3.8
20 + 25
2.00
2.50
3.0
4.5
5.9
600
1040
2030
5.0
4.8
4.6
20 + 35
1.89
3.31
3.0
5.2
5.9
600
1430
2030
6.7
6.4
6.2
25 + 25
2.50
2.50
3.0
5.0
5.9
600
1280
2030
6.1
5.8
5.6
25 + 35
2.17
3.03
3.0
5.2
5.9
600
1430
2030
6.7
6.4
6.2
<Cooling>
Indoor unit
combination
Heating capacity (kW)
Power consumption (W)
Standard current (A)
Indoor unit
capacity (kW)
Total capacity (kW)
Min.
Standard
Max.
220V
230V
240V
A
B
Min.
Standard
Max.
1
unit
20
3.0
-
1.3
3.0
3.7
520
750
1070
3.7
3.5
3.4
25
3.4
-
1.3
3.4
4.2
520
920
1210
4.5
4.3
4.1
35
4.5
-
1.3
4.5
5.0
520
1210
1450
5.9
5.6
5.4
2
units
20 + 20
2.25
2.25
2.0
4.5
6.3
550
900
1700
4.4
4.2
4.0
20 + 25
2.36
2.94
2.0
5.3
6.3
550
1150
1700
5.4
5.2
5.0
20 + 35
2.11
3.69
2.0
5.8
6.3
550
1290
1700
6.0
5.8
5.5
25 + 25
2.90
2.90
2.0
5.8
6.3
550
1290
1700
6.0
5.8
5.5
25 + 35
2.42
3.38
2.0
5.8
6.3
550
1290
1700
6.0
5.8
5.5
<Heating>
Indoor unit
combination
Cooling capacity (kW)
Power consumption (W)
Standard current (A)
Indoor unit
capacity (kW)
Total capacity (kW)
Min.
Standard
Max.
220V
230V
240V
A
B
Min.
Standard
Max.
1
unit
20
2.0
-
1.5
2.0
2.7
560
650
880
3.2
3.1
3.0
25
2.5
-
1.5
2.5
3.2
560
830
1040
4.1
4.0
3.8
35
3.5
-
1.5
3.5
3.7
560
1100
1200
5.5
5.2
5.0
2
units
20 + 20
2.00
2.00
3.0
4.0
5.6
600
1050
1750
5.2
5.0
4.8
20 + 25
2.00
2.50
3.0
4.5
5.8
600
1300
2030
6.3
6.0
5.8
20 + 35
1.89
3.31
3.0
5.2
5.8
600
1600
2030
7.5
7.2
6.9
25 + 25
2.50
2.50
3.0
5.0
5.8
600
1420
2030
6.7
6.4
6.2
25 + 35
2.17
3.03
3.0
5.2
5.8
600
1600
2030
7.5
7.2
6.9
(b) Indoor unit SKM
**
ZSP-S models only
<Cooling>
(1) Model SCM40ZS-S
(a) Indoor unit SRK
ZMX-S models only
Содержание SCM40ZS-S
Страница 114: ...113 16 SCM T 199 source PJA012D783...
Страница 200: ...199 16 SCM T 199 4 Troubleshooting procedure If the air conditioner runs NO NO NO NO YES YES YES YES 200 201 207 201 207...
Страница 285: ...284 16 SCM T 199 B PJZ012D077 2 Model RC EX1A eco touch REMOTE CONTROL RC EX1A INSTALLATION MANUAL...
Страница 311: ...310 16 SCM T 199 4 10 5 Superlink E board SC ADNA E F SL2NA E and SL4 AE BE to control...
Страница 312: ...311 16 SCM T 199...