6) Debugger
This sets whether the debugger will be used or not used, which
channel (CH1/CH2) will be used, and whether software will be used or
not used.
• Channel setting : Sets which channel the debugger is connected to.
(Cannot be connected to CH3.)
• Software Used : PC/AT personal computer that uses SW1IVD-
AD51HP-E
Not used
: VT-382, VG-620 (However, these have already
gone out of production.)
(2) Mode setting switch
Setting No.
Content
Remarks
0000
H
0001
H
Run mode
Mode for executing the BASIC program.
0002
H
0003
H
Multitask debug mode
Mode for debugging by connecting a
debugger.
0004
H
Programming
mode
Mode for programmimg by connecting a
console.
0005
H
to 000F
H
Setting
prohibited