3

2. Parts Names

Ŷ

  Remote controller (Optional parts)

Radio frequency interface

Wired remote controller

ON/OFF

TEMP.

RF thermostat

3. Operation

Ŷ

  About the operation method, refer to the operation manual that comes 

with each remote controller.

3.1.  Operation mode select

Cool/Fan/Heat/Automatic (cool/heat)/Ventilation modes are available.

Note:

Ɣ

  Heat and Automatic modes can not be available for cooling only units.

Ɣ

  Ventilation mode: only indicated on the following condition.

Wired remote controller is used and LOSSNAY is connected.

Ɣ

 Automatic mode

•  According to a set temperature, cooling operation starts if the room 

temperature is too hot and heating operation starts if the room tem-
perature is too cold.

•  During automatic operation, if the room temperature changes and 

remains 4 °F [2 °C] or more above the set temperature for 15 minutes, 
the air conditioner switches to cooling mode. If the room temperature 
remains 4 °F [2 °C] or more below the set temperature for 15 minutes, 
the air conditioner switches to heating mode.

Cooling mode

15 minutes (switches from 
heating to cooling)

Set tempe4 °F [2 °C]

Set temperature

Set temperature -4 °F [-2 °C]

15 minutes (switches 
from cooling to heating)

3.2.  Fan speed setting

Note:

Ɣ

 

In the following cases, the actual fan speed generated by the unit will differ 
from the speed shown the remote controller display.
1.  When the unit is in STAND BY or DEFROST states.
2. When the temperature of the heat exchanger is low in the heating mode. 

(e.g. immediately after heating operation starts)

3. In HEAT mode, when room temperature is higher than the temperature 

setting.

4.  When the heater control mode is the factory setting and the heater is on, 

the fan will operate at high speed.

3.3. Ventilation

Ź

 

For LOSSNAY combination

Ɣ

  The following 2 patterns of operation are available.

•  Run the ventilator together with the indoor unit. 
•  Run the ventilator independently. 

Note:

Ɣ

  With some model con

¿

 gurations, the fan on the indoor unit may come on 

even when you set the ventilator to run independently.

Note (for wireless RF thermostat):

Ɣ

  Running the ventilator independently is not available.

Ɣ

  No indication on the remote controller.

Содержание PVA-A30 AA4

Страница 1: ...read this operation manual thoroughly before operating the air conditioner unit English FOR USER P SERIES MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d uti...

Страница 2: ...t with wet hands An electric shock may result Do not spray combustible gas close to the unit Fire may result Do not place a gas heater or any other open ame appliance where it will be exposed to the a...

Страница 3: ...the air conditioner switches to heating mode Cooling mode 15 minutes switches from heating to cooling Set temperature 4 F 2 C Set temperature Set temperature 4 F 2 C 15 minutes switches from cooling...

Страница 4: ...operation and turn OFF the power supply Indoor units are equipped with lters to remove the dust of sucked in air Clean the lters using the methods shown in the following sketches Filter removal Cauti...

Страница 5: ...he wired remote controller display appears in the wired remote controller display 1 During central control appears in the wired remote controller display and air conditioner operation cannot be starte...

Страница 6: ...tion room hotel lobby etc Of ce hotel room Noise levels 3 to 7 dB 6 to 10 dB 9 to 13 dB Nothing appears in the wireless remote controller display the display is faint or signals are not received by th...

Страница 7: ...une lectrocution Ne vaporisez pas de gaz in ammable proximit de l appareil Cela risquerait de provoquer un incendie Ne placez pas un chauffage au gaz ou tout autre appareil fonction nant avec une amm...

Страница 8: ...s de la temp rature d nie pendant 15 minutes Mode de refroidissement 15 minutes passage du mode de chauffage au mode de refroidissement Temp rature d nie 4 F 2 C Temp rature d nie Temp rature d nie 4...

Страница 9: ...yage arr tez l appareil et coupez l alimentation Les appareils int rieurs sont quip s de ltres servant extraire les poussi res de l air aspir Nettoyez les ltres selon les m thodes illustr es ci apr s...

Страница 10: ...commande distance c bl e 1 Lors du contr le centralis le signe s af che sur l cran de la com mande distance c bl e et le fonctionnement du climatiseur ne peut pas tre activ ou d sactiv l aide de la co...

Страница 11: ...e radio diffusion salle de musique etc Salle de r ception entr e d h tel etc Bureau chambre d h tel Niveaux sonores 3 7 dB 6 10 dB 9 13 dB Rien ne s af che sur l cran de la t l commande sans l l af ch...

Страница 12: ...TOKYO 100 8310 JAPAN PA79D212H03 Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the resid...

Отзывы: