15
INDOOR UNIT
PLA-A12BA PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PLA-A42BA
3
OUTLINES AND DIMENSIONS
Unit: inch (mm)
14-27/32
11-3/16
2-3/8
+5 0
(7.5)
(160)
(500)
(950)
Floor
Min.94-1/2(2400)
from floor
Entire
periphery
(36)
(83)
(83)
(36)
(500)
(950)
(597)
(597)
( 158)
(
[
175)
(350)
(
[
150)
(14-
[
2.8
)
(167)
(155)
(130)
(100)
(90)
(90)
(100)
(100)
(35)
(17 )
+3/16
0
(190)
(156)
(105)
(50~70)
(140)
(170)
(377)
(284)
(60)
(24)
(187.5)
(840)
(160)
(160)
(20~45)
to 1-25/32
(860~910)
(620)
(605 )
-
3/16
+1-3/8
-
5
+35
(90)
(150)
(160)
(7.5)
(20
~
45)
1-25/32
Corner pocket
In case of wireless remote controller
In case of standard grille
Drain hole
Drain pump clean hole
and Drain emergency
drainage hole
For MA-Remote controller
terminal block
Emergency operation switch<Cooling>
Emergency operation
switch<Heating>
Indoor unit
Ceiling
Cut out hole
Burring hole pitch
3-
[
1/8(3-
[
2.8)
Burring hole
Detail drawing of fresh air intake hole
Burring hole
14-
[
1/8
Cut out hole
Burring hole pitch
Cut out hole
Detail connecting of branch duct(Both aspects)
(77)
3-1/32
(85)
3-11/32
(298)
11-3/4
11-1/16
(281)
(74)
(80)
(258)
(241)
2-29/32
3-5/32
10-3/16
PLA-A36BA
PLA-A42BA
PLA-A24BA
PLA-A30BA
9-1/2
D
C
B
A
2
Refrigerant pipe
····
[
15.88mm
Flared connection
····5/8
Refrigerant pipe
····
[
12.7mm
Flared connection
····1/2
1
Refrigerant pipe
····
[
6.35mm
Flared connection
····1/4
Refrigerant pipe
····
[
9.52mm
Flared connection
····3/8
Models
PLA-A12BA
PLA-A18BA
Min.19-11/16(500)
Grille
Ceiling
Suspension bolt
lower edge
Vane motor
Air intake grille
Air outlet hole
Air outlet hole
Auto vane
(Air outlet)
Air intak
e hole
Air intake hole
Grille
Ceiling
Keep 25/64(10)to 19/32(15)
between unit ceiling
and ceiling slab.
)
(
Connected the attached
flexible pipe or socket.
Drain pipe
connected to VP-25
Suspension bolt
M10 or W3/8
Branch duct hole
Fresh air
intake hole
Branch duct
hole
Ceiling hole
Suspension bolt pitch
Suspension bolt pitch
Ceiling hole
(5/16)
(5/16)
23-13/16
24-13/32
DEFROST/STAND BY lamp
Receiver
Operation lamp
For wiring replacement kit
terminal block
6-5/16
6-5/16
1
2
3-15/16
5-1/8
13-25/32
3-17/32
3-15/16
3-15/16
3-17/32
6-9/16
6-3/32
[
5-29/32
[
6-7/8
19-11/16
19-1
1/16
23-1/2
M
M
M
M
3-17/64
1-27/64
37-3/8
3-17/64
1-27/64
37-3/8
23-1/2
1-15/16~2-3/4
5-1/2
6-1
1
/16
1-3/8
11
/1
6
4-1/8
6-9/64
7-15/32
A
B
6-5/16
33-1/16(840)
5-29/32
3-17/32
C
D
33-1/16
7-3/8
25/32 to 1-25/32(20~45)
25/32 to 1-25/32(20~45)
33-27/32 to 35-13/16(860~910)
31-7/8(810)
25/32 to
33-27/32 to 35-13/16
25/32
15/16
6-5/16
Indoor unit/Outdoor unit
connecting terminal block
[
4-29/32(
[
125)
[
3-15/16(
[
100)
6-7/32
120°
120°
w
w
w
w w
w
w
w
w
w
Note1. As for drain pipe, please use VP-25(O.D.1-1/4(32mm) PVC TUBE).
Drain pump is included.
Max. lifting height is 33-7/16(850mm) from the ceiling.
2. As for suspension bolt, please use M10 or W3/8.
(Procured at local site)
3. Electrical box may be removed for the service purpose.
Make sure to slack the electrical wire little bit for
control/power wires connection.
4. The height of the indoor unit can be adjusted
with the grille attached.
5. For the installation of the optional high efficiency filter
or optional multi-functional casement.
1) Add 5-5/16(135mm) to the dimensions
w
marked on the figure.
2) Optional high efficiency filter must be used jointly with optional
multi-functional
casement.
6. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation and dripping may occur.
(It becomes the cause of dew drops/water dew.)
7. As for necessary installation/service space, please refer to the
left
figure.
DOCS14̲15revA.indd 15
DOCS14̲15revA.indd 15
10.8.25 4:09:19 PM
10.8.25 4:09:19 PM
Содержание PLA-A12BA
Страница 21: ...21 PEAD A24AA PEAD A30AA PEAD A36AA PEAD A42AA Unit mm inch...
Страница 26: ...26 WIRED REMOTE CONTROLLER 130 5 1 8 120 4 3 4 19 3 4 48 5 1 15 16 Unit mm inch...
Страница 35: ...35 PEAD A24AA PEAD A30AA PEAD A36AA PEAD A42AA...
Страница 99: ...99...