OC275-24
2-2 DRY operation
<How to operate>
1
Press POWER ON/OFF button.
2
Press MODE button to set operation mode to DRY.
3
Set desired temperature with or button.
NOTE: 1. Set temperature changes by 2 °F in the range 65~87 °F
each TEMP
or button is pressed.
2. Set temperature is displayed on the LCD.
(1)Compressor control
1
3-minute time delay
To prevent overload, the compressor will not start within 3 minutes after stop.
2
The compressor runs when the room temperature is higher than the set temperature.
The compressor stops when the room temperature is equal to or lower than the set temperature.
3
The compressor stops in check mode or during protective functions.
4
The compressor will not start when the room temperature is below 63 °F. The compressor starts intermittent operation when
the power is turned ON with room temperature above 63 °F. The compressor ON/OFF time depends on the thermostat
ON/OFF and the room temperature as follows.
After 3-minute compressor operation,
●
If the room temperature thermistor reads above 83 °F with thermostat ON, the compressor will operate for 6 more min-
utes and then stop for 3 minutes.
●
If the room temperature thermistor reads 79 °F to 83 °F with thermostat 0N, the compressor will operate for 4 more min-
utes and then stop for 3 minutes.
●
If the room temperature thermistor reads 75 °F to 79 °F with thermostat ON, the compressor will operate for 2 more min-
utes and then stop for 3 minutes.
●
If the room temperature thermistor reads below 75 °F with thermostat ON, the compressor will stop for 3 minutes.
●
If the thermostat is OFF, regardless of room temperature, the compressor will stop for 10 minutes.
5
Coil frost protection
Coil frost protection in DRY operation is the same as in COOL operation.
6
Coil freeze prevention
Coil freeze prevention does not operate in DRY operation.
Thermostat
Operation starts by
POWER button
ON.
ON
OFF
Indoor fan
ON
OFF
Auto vane
ON
OFF
Compressor
ON
OFF
w
2 Even if the room temperature rises above the set temperature during this period, the compressor will not start until this period has ended.
LOW speed
CLOSE
CLOSE
LOW speed
Depends on remote controller setting
MIN. 3 minutes
w
2
Room temperature
becomes equal to
set temperature.
Room temperature
rises above set
temperature.
Operation stops by
POWER button
OFF.
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
FAN
˚F
DRY
AM
OC275--1.qxp 01/12/14 3:06 PM Page 24