12
REFRIGERANT SYSTEM DIAGRAM
7
MUZ-A18YV -
MUZ-A24YV -
E1
E1
OUTDOOR UNIT
Unit:mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT62
Discharge
temperature
thermistor
RT61
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
[
3.6
✕
[
2.4
✕
50
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
[
12.7 (MUZ-A18YV)
(with heat insulator)
[
15.88 (MUZ-A24YV)
Refrigerant pipe
[
6.35
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Strainer
#100
Receiver
Outdoor heat
exchanger
temperature
thermistor
RT68
Strainer
#100
MUZ-A26YV -
E1
OUTDOOR UNIT
Unit:mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT62
Discharge
temperature
thermistor
RT61
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
[
3.6
✕
[
2.4
✕
50
Capillary tube
[
1.8
✕
[
0.6
✕
1000
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
[
15.88
(with heat insulator)
Refrigerant pipe
[
9.52
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Oil separator High-pressure
switch
Strainer
#100
Receiver
Outdoor
heat
exchanger
temperature
thermistor
RT68
Strainer
#100
Strainer
#100
OB346A --1qxp 04.6.14 1:20 PM Page 12
Содержание MUZ-A18YV