13
MUH-A30WV -
E1
OUTDOOR UNIT
Unit:mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
[
3.6
✕
[
2.4
✕
50
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
[
15.88
(with heat insulator)
Refrigerant pipe
[
9.52
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Strainer
#100
Receiver
Muffler
Ambient
temperature
thermistor
RT63
Strainer
#100
Indoor
unit
w
Max. Height
difference:
10m(MSH-A18/A24WV)/
15m(MSH-A30WV)
A
Refrigerant Piping
Max. Length
w
Height difference should be within 10m(MSH-A18/A24WV)/
15m(MSH-A30WV) regardless of which unit, indoor or outdoor position is high.
Outdoor unit
MAX. HEIGHT DIFFERENCE
MAX. REFRIGERANT PIPING LENGTH
Model
Piping size O.D : mm
Length of connecting pipe : m
Refrigerant piping
Max. length : m
A
25
30
Indoor unit
Gas 0.43
Liquid 0.5
Gas
12.7
15.88
Liquid
6.35
9.52
MUH-A18WV -
E1
MUH-A24WV -
E1
MUH-A30WV -
E1
Outdoor unit
Gas 0
Liquid 0