Maintenance
13. Maintenance
Do not use detergents, cleaning agents for heat
exchange equipment, abrasive powders, chemically
treated dusters, gasoline, benzene, thinners or other
solvents, as they can damage the unit or the water
tank, which may result in leakage.
Remove the power plug before you begin
maintenance.
Frequency and Parts for Maintenance
Tank
Unit
→
Wipe with a dry
cloth
When dirty
Silver ion filter
Air intake
Sensor
→
Clean with a
vacuum cleaner
Once every two
weeks
→
Soak in water
Once every three
months
When dirty
Water tank · Unit
Wipe with a soft cloth.
The unit draws in dust present in the air, and this
may cause the tank to gradually become dirty .
If the dirt does not come off easily, wash with cold
or warm water, then wipe with a soft, dry cloth.
Mildew may form in the tank unless kept clean.
Floating element
Do not remove or
dismantle.
Flashes or lights
Silver Ion Filter, Air Intake, and Sensor
Once every two weeks or when the CLEAN FILTER
lamp flashes or lights
1
2
3
4
5
6
Resetting the
CLEAN FILTER lamp
Clogging with dust and the like reduces the effectiveness
of the dehumidifying. Clean once every two weeks.
①
Insert the power plug in
a power socket.
②
Press the RESET switch
until you hear a beep (for
approximately 3 seconds).
Remove any dust from the
white net surface with the
nozzle of a vacuum cleaner.
Do not use a nozzle with a brush.
This may damage the filter.
< When the filter is very dirty>
Soak the filter in water.
Remove the filter cover.
Clean the filter.
Clean the air intake and sensor.
Set the silver ion filter into
the filter cover.
Set the filter cover.
Remove the silver ion filter
from the filter cover.
Remove any dirt with
a vacuum cleaner.
Do not use a nozzle
with a brush.
This may damage
the filter.
Make sure the silver ion filter is attached to
the unit. if it is not, fine dust will enter inside
the unit and cause a malfunction.
Press the POWER switch to turn off the power, wait until
the blower fan stops rotating (approximately 2 minutes)
before unplugging the power cord.
Sensor
Air
intake
Press
until you hear a beep.
Silver ion filter
30
Содержание MJ-EZ6CX-S1-IT
Страница 50: ...Issued in 2010 7 ...