5
¡
Auto
The unit maintains the humidity level by
automatically controlling airflow and operating
intermittently as necessary. All you have to do
is set the humidity level.
¡
The unit turns off when current humidity
decreases past the set humidity level, and
restarts when the level is exceeded.
¡
The unit operates for 6 minutes continuously
regardless of the humidity level immediately after
turning the power on.
Frequent use of exits and room
size/conditions may cause the humidity to not
reach the set level.
<To view set humidity level/ To set humidity level>
¡
Pressing the button once displays the
set humidify level with the
indicator. After 3 seconds, the display
returns to the current humidity display.
¡
Pressing HUMIDITY SELECTION while
is displayed sets the
humidity level. Each time the button is
pressed, the humidity setting changes.
<Modes>
¡
Easy Dehumidifying
The unit automatically controls airflow to counter excessive
room temperature/humidity. It activates the blower at high
temperatures.
50
0
20
30
27
60
Humidity
le
vel (%)
Room temperature (
°
C)
¡
Room temperature is below 27
°
C - the unit
automatically sets the humidity level
according to the temperature.
¡
Room temperature is above 27
°
C - the unit lowers
the humidity level to 50%, then activates the blower.
The dehumidifier is reactivated when humidity rises
to 60%.
¡
Easy Laundry
The unit operates for 12 hours and automatically switches off.
∞
Empty the water tank before operating the unit. The unit may stop before the clothes are dry due to a full tank.
∞
Do not use in conjunction with OFF Timer mode. The unit may stop before the clothes are dry.
∞
The following conditions prevent clothes from drying well:
Room temperature below 15
°
C, large volume of laundry; laundry not spaced well; clothes of thick fabric
and spacious room.
∞
When the room temperature is below 5
°
C, less water evaporates from the
clothes, decreasing the amount of temperature change. Therefore the unit is
unable to detect the state of the laundry and may turn off after 1 hour
.
∞
Restart the unit if it turns off before the laundry dries (except when the temperature is
below 5
°
C).
Information
Use standard
Effective
floor area
~ 12 m
2
Use standard
Effective
floor area
~ 10 m
2
Laundry
Up to
volume
approx. 4 kg.
¡
Low
The unit continually operates the dehumidifier
regardless of current humidity.
¡
Low Temp
The unit operates continuously automatically
controlling airflow according to room
temperature. The air flow is strongest below
15
°
C. The use of Low Temp mode is
recommended when the Low temperature
indicator is lit.
When the temperature is low,
condensation may still form on
windows exposed to the outside air even when
Low Temp mode is operating
Information
¡
LAUNDRY
Continuous dehumidifying regardless of
current humidity at high airflow.
¡
Air Purifier
Cleans the air by passing it through the air
filter.
The dehumidifying function is off.
Air passes through the air filter when the
dehumidifying function is on.
¡
Mildew Guard
The unit lowers room humidity levels once a day (for approximately 2-4
hours), suppressing mildew growth.
∞
Refrain from turning on ventilation fans or opening windows or doors as this lowers performance.
∞
Mildew growth may still occur due to the fungus type and conditions of the room.
E.g. Rooms that contain excessive condensation, bathrooms, and places with bad airflow
(insides of closets and behind furniture).
∞
This mode does not remove existing mildew.
∞
Do not use in conjunction with OFF Timer mode.
Information
ON
24 hours
24 hours
Dehumidifies
Dehumidifies
Standby
Standby
Use standard
Effective
floor area
~ 12 m
2
¡
Once every 24 hours the dehumidifier runs for 2
hours if the humidity is 40%, or 4 hours if at
50%. The unit operates intermittently,
automatically turning on and off according to
the humidity level of the room.
¡
The unit continues operation if the humidity level
does not decrease.
Information
65
70
50
55
60
Press
SELECTION
SELECTION
E16S E16SX
E16S E16SX
E16S
E16S
E16SX
E16SX
E16S E16SX
E16SX
Содержание MJ-E16S-S1
Страница 21: ...21 6 4 Board Diagrams Componet Side Power supply board diagram Control board E16S E16SX ...
Страница 22: ...22 6 5 General Block Diagram E16S ...
Страница 23: ...23 ...
Страница 24: ...24 E16SX ...
Страница 25: ...25 ...
Страница 40: ...40 Parts Catalog Model MJ E16S SX S1 Exploded View Electrical Parts 3 b c 5 4 2 1 6 d 9 8 7 a ...
Страница 48: ...Issued in 2003 06 Printed in Japan ...