background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be 
the cause of Mitsubishi; machine damage or lost profits caused by faults in the 
Mitsubishi products; damage, secondary damage, accident compensation 
caused by special factors unpredictable by Mitsubishi; damages to products 
other than Mitsubishi products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE

HIMEJI WORKS

 : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, 
   JAPAN
 : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

B

Side

A

Side

B

JAPANESE

ENGLISH

JY997D20801A

Safety Precaution

 

(Read these precautions before use.)

This manual classify the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also be

linked to serious results.
In any case, it is important to follow the directions for usage.

Associated Manuals

Note: FX

3UC

 Series PLC specification details for I/O, wiring, installation, and

maintenance can only be found in the Japanese Manual.

How to obtain manuals

For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchase your product.

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3U

 / FX

3UC

 Series 

User's Manual 
- Analog Control 
Edition

JY997D16701

MODEL CODE: 

09R619

Describes specifications for 

analog control and 

programming method for FX

3U

 

/ FX

3UC

 Series PLC.

FX

3U

/FX

3UC

 Series 

Programming Manual 
-   B a s i c   &   A p p l i e d
Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming

for basic/applied instructions

and devices.

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains FX

3U

 Series PLC

specification details for I/O,

w i r i n g ,   i n s ta l l a t i o n ,   a n d

maintenance.

Certification of UL, cUL standards

The following product has UL and cUL certification.

UL, cUL File Number:E95239
Models:

MELSEC FX

3U

 series manufactured

FX

3U

-

4DA

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more details please contact the
local Mitsubishi Electric sales site.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (89/336/EEC) when
used as directed by the appropriate documentation.

Type:

Programmable Controller (Open Type Equipment)

Models:

MELSEC FX

3U

 series manufactured

from February 1st, 2006

FX

3U

-4DA

Caution for EC Directive

The analog special adapters have been found to be compliant to the European 
standards in the aforesaid manual and directive. However, for the very best per-
formance from what are in fact delicate measuring and controlled output device 
Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered care-
fully. For users of proprietary cables (integral with sensors or actuators), these 
users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other 
EMC protection is provided, then users may experience temporary induced 
errors not exc10%/-10% in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are fol-
lowed with general good EMC practice for the users complete control system, 
users should expect normal errors as specified in this manual.

Sensitive analog cable should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible users should run analog
cables separately.

Good cable shielding should be used. Ground the shield of the twisted
shielded cable at one point on the signal receiving side.

Please use FX

3U

-4DA while installed in a shielded enclosure. For the details,

refer to the following manual.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition

1. Outline

The FX

3U

-4DA special function block for analog output converts digital values supplied

from PLC into analog values (voltage, current) and outputs those analog values from its
four output points. 

1.1 Incorporated Items

Check if the following product and items are included in the package:

Standard

Remark

EN61131-2:2003
Programmable controllers

- Equipment requirements and

tests

Compliance with all relevant aspects of the
standard.
• Radiated Emissions
• Mains Terminal Voltage Emissions
• RF immunity
• Fast Transients
• ESD
• Surge
• Conducted
• Power magnetic fields

JY818D33101A

Special Unit/Block No.

No.0

No.1

No.2

No.3

No.4

No.5

No.6

No.7

Product

Dust proof sheet 

× 

Special unit/block

No. label

Manual

This

manual

1.2 External Dimensions, Part Names, and Terminal Layout

1.2.1

External Dimensions and Part Names 

1.2.2 Terminal Layout

2. Installation  

2.1 Arrangements

The product connects on the right side of an PLC main unit or extension units/blocks
(including special function units/blocks). 
For connection to FX

3UC

 Series PLC or FX

2NC

 Series PLC extension block, FX

2NC

-

CNV-IF or FX

3UC

-1PS-5V is required. 

For further information of installation arrangements, refer to the following manual.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition

[1] Direct mounting hole:2 holes of 

φ

4.5 (0.18") (mounting screw: M4 screw)

[2] Extension cable
[3] POWER LED (green):

Lit while 5V DC power is supplied from PLC. 

[4] Terminal block for power supply (24V DC) (M3 terminal screw)
[5] Terminal block for analog output 
[6] 24V LED (red):

Lit while 24V DC power is supplied properly to terminals [24+] and [24-].

[7] D/A LED (red):Flashes (at high speed) during D/A conversion. 
[8] DIN rail mounting hook
[9] DIN rail mounting groove (35 mm (1.38") wide)

INSTALLATION 
PRECAUTIONS

Use the product in the environment within the general specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts, corrosive
gas (salt air, Cl

2

, H

2

S, SO

2

, or NO

2

), flammable gas, vibrations or impacts, or

expose it to high temperature, condensation, or wind and rain.
If the product is used in such a place described above, electrical shock, fire,
malfunction, damage, or deterioration may be caused.

Do not touch the conductive parts of the product directly, thus avoiding failure or
malfunction.

Install the product securely using the DIN rail or screws.

Install the product on a flat surface. 
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformity.

When drilling screw holes or wiring, cutting chips or wire chips should not enter
ventilation slits.
Such an accident may cause fire, failure or malfunction.

Be sure to remove the dust proof sheet from the PLC's ventilation port when the
installation work is completed.
Failure to do so could cause fires, equipment failures, and malfunctions.

Fit the extension cables and communication cables securely to the designated
connectors.
Contact failures may cause malfunctions.

FX

3U

-4DA

FX

3U

-4DA

24V
D/A

[1]

[2]

[6]

[7]

[3]

[4]

[5]

[9]

[8]

80(3.15")

(mounting hole pitch)

90(3.55")

[Without top cover]

MASS(Weight) : Approx. 0.2kg(0.44lbs)

55(2.17")

87(3.43")

9(0.36")

4(0.16")

24+

24- V+

I+

VI-

V+

I+

V+

VI-

VI-

I+

V+

I+

VI-

CH1

CH2

CH3

CH4

Left side of the product

(Extension cable side)

2.2 Mounting

The product is mounted by the following method. 

Direct mounting

DIN rail mounting

2.2.1

Direct Mounting

The product can be mounted with M4 screws by using the direct mounting holes. 
Refer to the External Dimensions (section 1.2) for the product’s mounting hole
pitch information. 
An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary. 
For further information of direct installation, also refer to the following manual. 

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition

2.2.2

DIN Rail Mounting

The product can be mounted on a DIN rail (DIN46227, 35mm width).

1) Fit the upper edge of the DIN rail mounting

groove (right fig. A) onto the DIN rail. 

2) Press the product against the DIN rail. 

3) Connect the extension cable (right fig. B)

to the main unit, input/output extension unit/
block, and special function unit/block on the
left. 
For the details of the extension cable con-
nection, refer to the following manual. 

→ 

Refer to the FX

3U

 Series User's Manual

- Hardware Edition

1)

2)

A

3. Wiring

  

3.1 Applicable Cable and Terminal Tightening Torque

The size of the terminal screws is M3.
The end disposal of the cable shows below.
Tighten the terminal to a torque of 0.5N

m to 0.8N

m.

When one wire is connected to one terminal

When two wires are connected to one terminal

3.2 Power Supply Wiring

For the power supply wiring, refer to the following manual. 

→ 

Refer to the FX

3U

 / FX

3UC

 Series User’s Manual

- Analog Control Edition

3.3 Wiring of Analog Output

→ 

For the terminal layout, refer to Subsection 1.2.2

WIRING 
PRECAUTIONS

Cut off all phases of power source externally, before installation or wiring
work in order to avoid electric shock or damage of product.

WIRING 
PRECAUTIONS

Make sure to observe the precautions below in order to prevent any damage
to a machine or any accident which might be caused by abnormal data
written in the PLC due to the influence of noise:

1) Do not lay close or bundle with the main circuit, high-voltage power line,

or load line. 
Otherwise effects of noise or surge induction are likely to take place.
Keep a safe distance of more than 100 mm (3.94") from the above when
wiring.

2) Ground the shield of the twisted shielded cable at one point on the signal

receiving side. However, do not ground at the same point as high voltage
lines.

Properly perform wiring to the terminal block following the precautions below
in order to prevent electrical shock, short, wire break, or damage to the
product.

- Termination of the wire should follow the dimensions described in this manual. 
- Tightening torque should be 0.5 to 0.8 N

m. 

φ

3.2 (0.13")

6.2 mm (0.24")

or less

’[Žq

Terminal

screw

Crimp

terminal

Terminal

6.2 mm (0.24")

or less

φ

3.2 (0.13")

6.3 mm(0.25")
or more

6.3 mm(0.25")
or more

Terminal

screw

Crimp

terminal

Terminal

6.2 mm (0.24")

or less

6.2 mm (0.24")

or less

φ

3.2 (0.13")

φ

3.2 (0.13")

FX

3U

-4DA

24V DC

+15V

I+

VI-

V+

24+

24-

*4

-15V

*2

I+

VI-

V+

External power

supply wiring

Using voltage output

Using current output

Grounding

(Ground resistance:

100

 or less)

Shield *3

Shield *3

*1

ch    :    represents the channel number.

ch

ch

ch

ch

*5

*5

*1 For FX

3U

 Series PLC (AC power type), the 24V DC service power supply is also

available. 

*2 Leave the [

] terminal unconnected. 

*3 Use a 2-core twisted shield wire for analog output line, and separate it from other

power lines or inductive lines.

*4 If there is ripple or noise in the output voltage, connect a capacitor of

approximately 0.1 to 0.47 

µ

F 25 V in the vicinity of the signal receiving side. 

*5 Ground the shielded wire at one point on the signal receiving side.

3.4 Grounding

Grounding should be performed as stated below.

The grounding resistance should be 100

 or less.

Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding"
of the following figure.

→ 

For details, refer to the FX

3U

 Series User's Manual

- Hardware Edition.

The grounding wire size should be AWG 14 (2 mm

2

).

The grounding point should be close to the PLC, and all grounding wire
should be as short as possible.

4. Specification 

 

4.1 Applicable PLC

The version number can be checked by monitoring D8001 as the last three digits
indicate it.

4.2 General Specification

The items other than the following are equivalent to those of the PLC main unit. 
For other general specifications, refer to the manual of the PLC main unit. 

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

4.3 Power Supply Specification

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.
Doing so may cause failure, malfunction or fire.
* For repair, contact your local Mitsubishi Electric distributor.

Do not drop the product or do not exert strong impact, doing so may cause
damage.

DISPOSAL 
PRECAUTIONS

Please contact a company certified in the disposal of electronic waste for
environmentally safe recycling and disposal of your device.

TRANSPORT AND 
STORAGE PRECAUTIONS

During transportation avoid any impact as the product is a precision instrument.
Check the operation of the product after transportation.

Model name

Applicability

FX

3U

 Series PLC

Ver. 2.20 (from the first product) and later

FX

3UC

 Series PLC

Ver. 1.30 (from the product manufactured in August, 2004 with
SER No. 48

!!!!

) and later

Item

Specification

Dielectric withstand 
voltage

500V AC for one minute

Conforming to JEM-1021
Between all terminals and
ground terminal of PLC
main unit

Insulation resistance

5M

 or more by 500V DC megger

Item

Specification

D/A conversion 
circuit driving power

24V DC 

±

10%, 160mA for 24V DC

Connect a 24V DC power supply to the terminal block.

CPU driving power

5V DC, 120mA
5V DC power is supplied internally from the main unit.

PLC

Another

equipment

PLC

Another

equipment

PLC

Another

equipment

Shared grounding

Good condition

Common grounding

Not allowed

Independent grounding

Best condition

4.4 Performance Specification

*1 Change the offset and gain values to change the output characteristics.

However, the resolution doesn’t change even when the offset and gain values
change.
When analog value (mV, 

µ

A) specification is enabled in the output mode 1 or 4,

the offset value and the gain value don’t change. 

*2 The offset and the gain should satisfy the following condition:

1 V 

 (Gain - Offset) 

 10 V

*3 The offset and the gain should satisfy the following condition:

3 mA 

 (Gain - Offset) 

 30 mA

*4 The output characteristics vary depending on the output mode to be used. 

For the details of the output characteristics, refer to the following manual. 

→ 

Refer to the FX

3U

 / FX

3UC

 Series User’s Manual

- Analog Control Edition

Item

Description

Voltage output

Current output

Analog output 
range

-10 to +10V DC
(External load: 1k

 to 1M

)

0 to 20mA, 4 to 20mA DC
(External load: 500 

 or less)

Offset

*1

-10 to +9V

*2

0 to 17mA

*3

Gain

*1

-9 to +10V

*2

3 to 30mA

*3

Digital input

With sign, 16bits, binary

15bits, binary

Resolution

0.32mV (20V/64000)

0.63

µ

A (20mA/32000)

Total accuracy

• ±

0.3% (

±

60mV) for full scale 

of 20V (when ambient 
temperature is 25

°

C

±

5

°

C)

• ±

0.5% (

±

100mV) for full scale 

of 20V (when ambient 
temperature is 0

°

C to 55

°

C)

• ±

0.3% (

±

60

µ

A) for full scale of 

20mA (when ambient 
temperature is 25

°

C

±

5

°

C)

• ±

0.5% (

±

100

µ

A) for full scale 

of 20mA (when ambient 
temperature is 0

°

C to 55

°

C)

A/D conversion 
time

1ms (The number of selected channels will not affect this value.)

Output 
characteristics

*4

Insulation 
method

The photo-coupler insulates the analog output area from the
PLC.

The DC-DC converter insulates the analog output area from the
power supply unit.

Channels are not insulated from each other.

Occupied 
points

8 point (Count either the input or output points of the PLC.)

Digital

value

+10

+10.2

-10.2

-10

-32000

+32000

+32640

-32640

Output mode 0

Output voltage(V)

0

20.32

4

32000

20

32640

Output mode 3

Output current(mA)

Digital value

Output mode 2

0

20.4

32000

20

32640

Output current(mA)

Digital value

4.5 Output characteristics

The output characteristics in each output mode are as follows. 

Output 

mode

Output mode

Analog output 

range

Digital input 

range

0

Voltage output mode

-10 to +10V

-32000 to +32000

1

Voltage output analog value
mV specification mode

-10 to +10V

-10000 to +10000

2

Current output mode

0 to 20mA

0 to 32000

3

Current output mode

4 to 20mA

0 to 32000

4

Current output analog value

µ

A specification mode

0 to 20mA

0 to 20000

FX

3U

-4DA

INSTALLATION MANUAL

This manual describes the part names, dimensions, mounting, and

specifications of the product. Before use, read this manual and manuals of

relevant products fully to acquire proficiency in handling and operating the

product. Make sure to learn all the product information, safety information, and

precautions.

And, store this manual in a safe place so that you can take it out and read it

whenever necessary. Always forward it to the end user.

Registration

The company name and the product name to be described in this manual are

the registered trademarks or trademarks of each company.

Effective February 2006
Specifications are subject to change without notice.

©

 2006 Mitsubishi Electric Corporation

Manual Number

JY997D20801

Revision

A

Date

February 2006

Отзывы: