14
Advanced Functions
Note
A point to notice
Info.
Supplementary information
Synchronous Recording
A number of camera images can be mixed together through a
camera switcher and then recorded separately onto several
VCRs. A camera is assigned to each VCR with the VCR
recording only the camera image it has been assigned. This
allows recording without gaps.
If you have 5 VCRs, the video signal from 5 cameras can be
recorded separately by connecting the switcher as shown below:
1. Press MENU button.
•
<MAIN MENU> appears.
2. Turn JOG to select REAR TERMINAL
and turn SHUTTLE to the right.
•
<REAR TERMINAL> menu
appears.
3. Turn JOG to select REC IN and turn
SHUTTLE to the right.
Steps 4 to 7 on VCR1 only:
4. Turn JOG to select SERIES or REC-
START/STOP and turn SHUTTLE to
the right.
•
If the recording start signal is
available on the switcher, select
SYNC REC.
5. Turn JOG to select CLOCK OUT and
turn SHUTTLE to the right.
6. Turn JOG to select T/L REC and turn
SHUTTLE to the right.
7. Turn JOG to select F and turn
SHUTTLE to the right.
Step 8 on all VCRs except VCR1:
8. Turn JOG to select SYNC REC and
turn SHUTTLE to the right.
9. Press MENU button.
•
The day and present time appears on screen.
page 21 for synchronous recording connection
V-SYNC
SWITCHER / switching
cameras
/ recording
start signal
VCR1
/ recording
/ clock out
VCR2
/ recording
/ clock out
VCR3
/ recording
/ clock out
VCR4
/ recording
/ clock out
VCR5
/ recording
/ clock out
CAMERA1 CAMERA2 CAMERA3 CAMERA4 CAMERA5 CAMERA1 CAMERA2 CAMERA3 CAMERA4 CAMERA5
REC
REC
REC
REC
REC
REC
REC
REC
REC
REC
<MAIN MENU>
DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
REC- 1
MODE OUT
REC
REC IN
SERIES
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
REC- 1
MODE OUT
REC
REC IN
SERIES
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
REC- 1
MODE OUT
REC
REC IN
REC-START/STOP
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
REC- 1
MODE OUT
REC
REC IN
SERIES
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
T/L REC- 1
MODE OUT
REC
REC IN
SERIES
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
T/L REC- F
MODE OUT
REC
REC IN
SERIES
<REAR TERMINAL>
CALL OUT
WRNG•TAPE END
CLOCK OUT
REC- 1
MODE OUT
REC
REC IN
SYNC REC
One shot/Interval Recording
One shot recording allows you to control the number of fields to
be recorded when the REC button is pressed or the REC IN
terminal is grounded. Interval recording is made at the selected
number of fields and at the selected interval.
1. Press REC/PLAY MODE button on the front panel to set the
recording mode to 0H.
2. Press MENU button.
•
<MAIN MENU> appears.
3. Turn JOG to select RECORDING SET
UP and turn SHUTTLE to the right.
•
<RECORDING SET UP> menu
appears.
4. Turn JOG to select ONE
SHOT•FIELD and turn SHUTTLE to
the right.
5. Turn JOG to select the number of
recording field and turn SHUTTLE to
the right.
6. Turn JOG to select ONE
SHOT•INTERVAL and turn SHUTTLE
to the right.
For one shot recording, setup step 7 only:
7. Turn JOG to select SHOT and turn
SHUTTLE to the right.
For interval recording, setup step 8 only:
8. Turn JOG to select the recording
interval and turn SHUTTLE to the
right.
9. Press REC button.
•
The one shot recording will be on standby mode.
•
The VCR starts the interval recording with the interval
time selected in step 8 above.
10. To start one shot recording, press REC button again or
contact the REC IN terminal on the rear panel to the ground.
Note
•
If no recording is made for about 5 minutes during one shot
recording standby mode, the VCR automatically records the
number of fields selected in step 5.
<MAIN MENU>
DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE
<RECORDING SET UP>
ALARM REC MODE
3H
ALARM REC DURATION
1M
EMERGENCY REC
OFF
CLOG DETECT
ON
ONE SHOT•FIELD
1
ONE SHOT•INTERVAL
10S
<RECORDING SET UP>
ALARM REC MODE
3H
ALARM REC DURATION
1M
EMERGENCY REC
OFF
CLOG DETECT
ON
ONE SHOT•FIELD
1
ONE SHOT•INTERVAL
10S
<RECORDING SET UP>
ALARM REC MODE
3H
ALARM REC DURATION
1M
EMERGENCY REC
OFF
CLOG DETECT
ON
ONE SHOT•FIELD
5
ONE SHOT•INTERVAL
10S
<RECORDING SET UP>
ALARM REC MODE
3H
ALARM REC DURATION
1M
EMERGENCY REC
OFF
CLOG DETECT
ON
ONE SHOT•FIELD
5
ONE SHOT•INTERVAL
10S
<RECORDING SET UP>
ALARM REC MODE
3H
ALARM REC DURATION
1M
EMERGENCY REC
OFF
CLOG DETECT
ON
ONE SHOT•FIELD
5
ONE SHOT•INTERVAL
SHOT
<RECORDING SET UP>
ALARM REC MODE
3H
ALARM REC DURATION
1M
EMERGENCY REC
OFF
CLOG DETECT
ON
ONE SHOT•FIELD
5
ONE SHOT•INTERVAL
30S
Recording Techniques (Cont.)
Содержание HS-1168E