5. ETHERNET CONNECTION
5.2 System Configuration
5 - 7
5
ETHERN
ET C
O
NN
ECTION
5.2
System Configuration
5.2.1
Connection to Ethernet module
When connecting to MELSEC-Q, QS, QnA, A or motion controller
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
A cross cable is available for connecting the GOT to the Ethernet module.
Ethernet
module
GOT
Connection cable
PLC CPU
Ethernet(MELSEC),Q17nNC,
CRnD-700,Gateway
Communication driver
PLC
Connection cable
*1
Maximum
segment
length
*3
GOT
Number of
connectable
equipment
Model name
Ethernet module
*3*4
Communication
type
Cable model
Option device
Model
MELSEC-Q
(Q mode)
MELSEC-QS
Motion controller
CPU (Q Series)
*5
QJ71E71-100
QJ71E71-B5
QJ71E71-B2
QJ71E71
Ethernet
• 100BASE-TX
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP)
of category 5 or higher
• 10BASE-T
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP)
of category 3 or higher
100m
- (Built into GOT)
128 GOTs
*6
(recommended
to 16 units or
less)
MELSEC-QnA
AJ71QE71N3-T
AJ71QE71N-B5
AJ71QE71N-B2
AJ71QE71N-T
AJ71QE71N-B5T
AJ71QE71
AJ71QE71-B5
A1SJ71QE71N3-T
A1SJ71QE71N-B5
A1SJ71QE71N-B2
A1SJ71QE71N-T
A1SJ71QE71N-B5T
A1SJ71QE71-B5
A1SJ71QE71-B2
Ethernet
MELSEC-A
MELSEC-Q
(A mode)
Motion controller
CPU (A Series)
AJ71E71N3-T
AJ71E71N-B5
AJ71E71N-B2
AJ71E71N-T
AJ71E71N-B5T
AJ71E71-S3
A1SJ71E71N3-T
A1SJ71E71N-B5
A1SJ71E71N-B2
A1SJ71E71N-T
A1SJ71E71N-B5T
A1SJ71E71-B5-S3
A1SJ71E71-B2-S3
Ethernet
MELSEC-L
LJ71E71-100
Ethernet
Содержание GOT2000 Series
Страница 2: ......
Страница 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 64: ......
Страница 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Страница 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Страница 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Страница 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Страница 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Страница 416: ......
Страница 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Страница 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Страница 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Страница 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Страница 542: ......
Страница 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Страница 568: ......
Страница 592: ...19 24 19 MULTI CHANNEL FUNCTION 19 3 GOT Side Settings Example Setting example for Ethernet connection 4 channels ...
Страница 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Страница 600: ......
Страница 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Страница 670: ...REVISIONS 2 ...
Страница 673: ......