A-3

[MOUNTING PRECAUTIONS]

CAUTION

z

 The GOT should be used in the environment given in the general

specifications of this user's manual.
Not doing so can cause an electric shock, fire, malfunction or product
damage or deterioration.

z

 When mounting the GOT main unit to an enclosure, tighten the mounting

screws in the specified torque range.
Undertightening can cause a drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or module.

z

 When loading the communication board, communication module or

External I/O module to the GOT main unit, fit it to the connection interface
of the GOT and tighten the mounting screws in the specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage
of the screws or module.

z

 When loading the memory board into the GOT main unit, load it into its

corresponding GOT slot and tighten the mounting screws in the specified
torque range.
Undertightening can cause a malfunction due to a contact fault.
Overtightening can cause a malfunction due to the damage of the screws
or module.

z

 When loading the PC card into the GOT main unit, insert and push it into

its corresponding GOT slot until the PC card eject button  comes up.
Not doing so can cause a malfunction due to a contact fault.

z

 Before loading or unloading the PC card to or from the GOT, set the

memory card access switch to the OFF position.
Not doing so can cause the PC card data to be corrupted.

z

 Be sure to support the PC card with your hand when removing it.

Otherwise, the PC card may drop, resulting in a failure or damage.

[WIRING PRECAUTIONS]

DANGER

z

 Before starting wiring, always switch off the GOT power externally in all

phases.
Not doing so may cause an electric shock, product damage or malfunction.

Содержание GOT MELSEC A960GOT-EBA

Страница 1: ...BD User s Manual Hardware Thank you for buying the MELSEC GOT Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL A900GOT U...

Страница 2: ...for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS DANGER z Some failures of the GOT main unit...

Страница 3: ...ction which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out The monitor screen disappears even when the screensaver is not set The monitor scr...

Страница 4: ...due to the damage of the screws or module z When loading the memory board into the GOT main unit load it into its corresponding GOT slot and tighten the mounting screws in the specified torque range...

Страница 5: ...us connection cable by inserting it into the connector of the connected module until it clicks After plugging check that it has been inserted snugly Not doing so can cause a malfunction due to a conta...

Страница 6: ...dule CAUTION z Do not disassemble or modify the module Doing so can cause a failure malfunction injury or fire z Do not touch the conductive and electronic parts of the module directly Doing so can ca...

Страница 7: ...closure can cause injury due to a drop CAUTION z While changing the backlight do not touch the circuit boards and electronic parts of the GOT Doing so can cause a failure or malfunction z When changin...

Страница 8: ...1 Section 3 2 Addition Section 5 4 Mar 2004 IB NA 80032 F Partial correction Section 5 4 MODEL CODE change Changed from 13JN45 to 1DM100 Aug 2004 IB NA 80032 G Addition Section 5 4 5 5 5 6 Partial cor...

Страница 9: ...r Section 15 5 6 Connection Cable Wiring 16 5 7 Precautions for back light replacement 17 Appendices 18 Appendix 1 Outline dimension drawing 18 Appendix 2 Depth dimension for when mounting each type o...

Страница 10: ...ystal A960GOT A960GOT EBA A960GOT EBD EL 1 This manual explains the GOT of function version B For specifications of GOTs of other function version refer to A985GOT A975GOT A970GOT A960GOT User s Manua...

Страница 11: ...Option Memory board Flash PC card 1 External I O interface module 1 Backlight Protective sheet Debug stand Others Audio output device Commercially available Printer Commercially available 1 Barcode r...

Страница 12: ...ontrol box Overvoltage category 2 II or less Contamination level 3 2 or less 1 For A975GOT TBA TBD B and A970GOT TBA TBD B it becomes 0 to 55 C 2 Indicates the element in the distribution system betwe...

Страница 13: ...r of write times 100 000 times Environmental protective structure 5 Front section Equivalent to IP67 NEMA4 Panel inside IP2X Outline dimensions 297 11 7 W 208 8 2 H 46 1 81 D mm inch 268 10 56 W 192 7...

Страница 14: ...ferences of the GOT A900 series by version a Environmental protective structure The environmental protective structure IP rating differs depending on the hardware version of GOT Specification Item A97...

Страница 15: ...1 s noise width and 25 to 60Hz noise frequency Dielectric withstand voltage 1500VAC for 1 minute across AC external terminals and earth 500VAC for 1 minute across DC external terminals and earth Insu...

Страница 16: ...ule interface Interface for loading the communication module 6 memory card interface Interface for loading the PC card 7 memory card ejection button Button used to withdraw the PC card 8 Speech output...

Страница 17: ...ng Torque Range Terminal block terminal screw M3 screw 59 to 88Nycm Mounting Fixture screw M4 screw Communication module mounting screw M3 screw Communication board mounting screw M3 screw Option modu...

Страница 18: ...der please consider the dimensions of the connector to be used and the bending radius of the cable Part B size When using a PC card or an audio output device for a connected cable connector and a wire...

Страница 19: ...in the following four locations at its top and bottom Top Bottom Mounting Position Mounting position c How to mount and fix the mounting fixture is given below 1 Insert the mounting fixture into the f...

Страница 20: ...L INPUT 100 240VAC LG FG 12 24VDC 0 1A L L RUN OUTPUT 2 DC24V INPUT 24VDC LG FG 12 24VDC 0 1A L L RUN OUTPUT INPUT 24VDC DC12 24V L L For application of external outputs of RUN OUTPUT please refer to...

Страница 21: ...operation or erroneous operation Tightening the terminal screws too far may cause damages to the screws and or the module resulting in fallout short circuits or erroneous operation z Be sure there ar...

Страница 22: ...inal for M3 screw Also be sure to tighten the M3 screw within tightening torque 0 55 to 0 88 Nym in order not to cause trouble y Do not bundle the 100VAC 200VAC and 24VDC wires with or run them close...

Страница 23: ...grounding 1 Independent grounding Best y For grounding a cable use the cable of 2 mm2 or more Position the ground contact point as closely to the sequencer as possible and reduce the length of the gro...

Страница 24: ...ble FG FG LG Power equipment Servo etc Apply single point grounding for one system 5 5 Connecting to the GOT Power Section The following diagram shows the wiring example of power lines grounding lines...

Страница 25: ...cuit high voltage heavy current or I O signal cables or lay them close to each other When using A8GT C EXSS 1 or A8GT C BS ground wires as below 1 When using A8GT C EXSS 1 cable FG LG N L PLC Disconne...

Страница 26: ...on version B JAN 2004 or later A9GT 70LTTBW A970GOT A970GOT SBA A970GOT SBD A970GOT LBA A970GOT LBD A9GT 70LTS The GOT hardware version and function version can be checked from the rating plate which...

Страница 27: ...inch Item A B C D E F G H I J K L M A975GOT A970GOT 297 11 70 208 8 20 235 9 26 229 9 02 288 11 35 199 7 84 10 0 40 46 1 81 40 1 58 6 0 24 34 1 34 31 1 22 15 4 0 61 A960GOT 268 10 56 192 7 56 204 8 0...

Страница 28: ...inch A9GT QBUSS A9GT BUSS 43 1 69 100 3 94 A9GT QBUS2S A9GT BUS2S 65 2 56 100 3 94 A9GT BUSSU A9GT BUS2SU 77 3 03 30 1 18 A9GT RS2 T 43 1 69 1 A9GT RS4 43 1 69 130 5 12 A7GT J71AP23 A7GT J71LP23 77 3...

Страница 29: ...20 MEMO...

Страница 30: ...el Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker...