SPECIFICATIONS
3.1 General Specifications
*1 When mounting a multimedia unit (GT16M-MMR), MELSECNET/H communication unit (GT15-J71LP23-25, GT15-J71BR13), or
CC-Link communication unit (GT15-J61BT13), the operating ambient temperature must be reduced 5 °C against the maximum
values described in general specifications.
*2 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this
instruction may cause a malfunction.
When an air purge is made inside the control panel by adding pressure, there may be a clearance between the surface sheet and
the screen making it difficult to use the touch panel, or the sheet may come off.
*3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical
power distribution network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*4 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.
Item
Specifications
Operating ambient
temperature
*1
Display section
0 to 50°C
Other than the
display section
0 to 55°C
Storage ambient temperature
-20 to 60°C
Operating ambient humidity
10 to 90% RH, non-condensing
Storage ambient humidity
10 to 90% RH, non-condensing
Vibration resistance
Compliant with
JIS B3502 and
IEC61131-2
Frequency
Acceleration
Half-amplitude
Sweep count
Under
intermittent
vibration
5 to 8.4Hz
-
3.5mm
10 times each in X,
Y and Z directions
8.4 to 150Hz
9.8m/s
2
-
Under
continuous
vibration
5 to 8.4Hz
-
1.75mm
-
8.4 to 150Hz
4.9m/s
2
-
Shock resistance
Compliant with JIS B3502, IEC 61131-2 (147 m/s
2
, 3 times each in X, Y and Z directions)
Operating atmosphere
No greasy fumes, corrosive gas, flammable gas, excessive conductive dust, and direct sunlight(Same as
storage atmosphere)
Operating altitude
*2
2000 m (6562 ft) max.
Installation location
Inside control panel
Overvoltage category
*3
II or less
Pollution degree
*4
2 or less
Cooling method
Self-cooling
Grounding
Grounding with a resistance of 100
or less
Содержание GOT 1000 GT16
Страница 1: ...GT16 User s Manual Hardware ...
Страница 2: ......
Страница 14: ...A 12 INDEX REVISIONS WARRANTY ...
Страница 193: ...10 3 Error Message and System Alarm 10 29 9 MAINTENANCE AND INSPECTION 10 TROUBLESHOOTING APPENDICES ...
Страница 210: ...App 17 ...
Страница 212: ...Index 2 Transportation Precautions App 15 U USB environmental protection cover 2 17 8 19 ...
Страница 217: ......