FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
173
9 Preparation for Wiring and Power Supply Wiring Procedures
9.2 Cable Connecting Procedures
1
Introducti
on
2
Features
and
Par
t Names
3
Product
Introduc
tion
4
Sp
eci
fic
ati
ons
5
V
ers
ion and
Peri
ph
er
al
D
evices
6
S
yst
em
C
onfi
guration
7
Input/Ou
tput
No
s., Un
it No
s.
8
Inst
allati
on
9
Prep
arati
on an
d
Pow
er Supp
ly
Wi
rin
g
10
Input W
iring
9.2.3
Terminal block (for europe) [expansion board and special adapters]
The expansion board and special adapters of a terminal block type have terminal blocks for Europe.
1.
Applicable products
2. Compliant electric wires and tightening torque
*1.
Old model name : CRIMPFOX ZA 3
*2.
Old model name : CRIMPFOX UD 6
WIRING PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING PRECAUTIONS
• Make sure to properly wire to the terminal block (European type) in accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit, wire breakage, malfunctions, or
damage to the product.
- The disposal size of the cable end should follow the dimensions described in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed.
Classification
Model names
Expansion Board
FX
3U
-485-BD
Special Adapters
FX
3U
-485ADP(-MB), FX
3U
-4AD-ADP, FX
3U
-4DA-ADP, FX
3U
-3A-ADP, FX
3U
-4AD-PT-ADP,
FX
3U
-4AD-PTW-ADP, FX
3U
-4AD-PNK-ADP, FX
3U
-4AD-TC-ADP, FX
3U
-4HSX-ADP,
FX
3U
-2HSY-ADP
Electric wire size
(stranded wire/solid wire)
Tightening
torque
End treatment
One electric wire 0.3mm
2
to 0.5mm
2
(AWG22 to 20)
0.22 to 0.25N•m
• Remove the coating of the stranded wire, twist
the core wires, and connect the wires directly.
• Remove the coating from the solid wire, and
connect the wire directly.
Two electric
wires
0.3mm
2
(AWG22)
×
2
Bar terminal with
insulating sleeve
0.3 mm
2
to 0.5 mm
2
(AWG22 to 20)
(Refer to the following outline
drawing of bar terminal.)
• Bar terminal with insulating sleeve
(recommended product)
AI 0.5-8WH (Phoenix Contact)
• Caulking tool
CRIMPFOX 6
*1
: Phoenix Contact
(CRIMPFOX 6T-F
*2
: Phoenix Contact)