FX-20P-E Handy programming panel
Monitor 8
8-4
Example: Monitoring device T0
•
When the set value is indirectly specified through a data register (D), the data register No.
and the present value of the data register are displayed as the set value.
M
TO
P R
K 100
K 250
In the step 4)
Display example
Decimal display
In hexadecimal display,
"H" is displayed.
The ON status of the
reset coil is monitored.
The OFF status of the output
contact is monitored.
Set value
Present value
0
T
GO
1)
2)
3)
4)
Key operation
S'P
Monitor function
M
TO
P R
K 100
D 0
K 250
When the set value is indirectly specified
Display example
Data register No.
Present value of data register