16
4.1 Setting the Frequency to Perform Operation
(Example: Performing Operation at 30Hz)
1.
Screen at power-on
The monitor display appears.
PU
EXT
2.
Press the key
to choose the PU operation mode.
PU
EXT
Flicker ... Frequency setting
complete!!
SET
3.
Turn the setting dial to show
the frequency you want to set.
The frequency flickers for
about 5 seconds.
4.
5.
6.
To change the set frequency, perform
the operation in above steps 3 and 4.
(Starting from the previously set frequency.)
7.
RUN
Press the key to stop.
STOP
RESET
SET
RUN
RUN
PU
EXT
RUN
PU
EXT
PU indication is lit.
RUN
PU
EXT
While the value is flickering, press
the key to set the frequency.
RUN
PU
EXT
3 s later
Flickers for
about 5 s
STOP
RESET
SET
If you do not press the key, the value
flickers for about 5 seconds and the display
then returns to 0.0 (monitor display).
At this time, return to "Step 3" and set the
frequency again.
Display
Operation
After the value has flickered for
about 3 seconds, the display
returns to 0.0 (monitor display).
Press the key to start operation.
Operation cannot be performed at the set frequency ... Why?
Did you carry out step 4 within 5 seconds after step 3? (Did you press the
SET
key within 5 seconds after turning the dial?)
Setting of higher than 60Hz cannot be made ... Why?
Check to see if the Pr. 1 "maximum frequency" setting is 60Hz.
The frequency does not change by turning the dial ... Why?
Check to see if the operation mode selected is the external operation
mode.
Remarks
Pressing the setting dial shows the set frequency.
•
The setting dial can also be used like a potentiometer to perform operation.
Set Pr. 30 "extended function display selection" to "1" (extended function
parameter valid) and Pr. 53 "frequency setting operation selection" to "1"
(setting dial potentiometer mode). Press the
RUN
key, turn the dial, and set
the frequency. After turning the setting dial, the frequency setting is changed
without pressing the
SET
key.