![Mitsubishi FR-EPN Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/mitsubishi/fr-epn/fr-epn_instruction-manual_1809396037.webp)
- 31 -
190
Get/Set
Motor Constant R1
9999
191
Get/Set
Motor Constant R2
9999
192
Get/Set
Motor Constant L1
9999
193
Get/Set
Motor Constant L2
9999
194
Get/Set
Motor Constant X
9999
195
196
Get/Set
Auto Tuning Setting/State
0
6.7.4. Class 0x2A Instance Services
#
Service
0x0E Get Attribute Single
0x10 Set Attribute Single
6.8.
A200E Extended Class 0x66
6.8.1. Class 0x66 Attributes - Instance 0
None
6.8.2. Class 0x66 Services
None
6.8.3. Class 0x66 Instance Attributes Instance 1
A200E Special Functions
#
Function
Access
Attribute
Default Value
1
Fn123
Get/Set
Operation Command Source
Net
2
Fn124
Get/Set
Frequency Command Source
Net
3
Fn125
Get/Set
Start Up Link Selection
0
4
Fn127
Get/Set
EEPROM Write Enable
Y
5
Fn145
Get/Set
PU Language Switching
0
6
Fn155
Get/Set
RT Activated Condition
0
7
Fn156
Get/Set
Stall Prevention Selection
0
8
Fn157
Get/Set
OL Signal Waiting Time
0.0
9
Fn158
Get/Set
AM Terminal Function Select
9999
10
Fn159
Get/Set
Carrier decreases Sel. Low
Speed
0