Component names
9
1
1.2
Component names
Component names are shown below. (Example: FR-A846-00250(7.5K))
Refer to the FR-A800 Instruction Manual (Detailed)
Symbol
Name
Description
Refer to
page
(a)
PU connector
Connects the operation panel or the parameter unit. This connector also enables
the RS-485 communication.
(b)
USB A connector
Connects a USB memory device.
(c)
USB mini B connector
Connects a personal computer and enables communication with FR Configurator 2.
(d)
RS-485 terminals
Enables RS-485, MODBUS RTU communication.
(e)
Plug-in option connector1
Connects a plug-in option or a communication option.
Instruction
Manual of
the option
(f)
Plug-in option connector2
(g)
Plug-in option connector3
(h)
Voltage/current input switch
Selects between voltage and current for the terminal 2 and 4 inputs.
(i)
Control circuit terminal block
Connects cables for the control circuit.
(j)
EMC filter ON/OFF connector
Turns ON/OFF the EMC filter.
(k)
Charge lamp
Stays ON while the power is supplied to the main circuit.
(l)
Metal fitting for earthing
(grounding)
Earths (grounds) the shielded wires of the encoder cable, etc.
(m)
Main circuit terminal block
Connects cables for the main circuit.
(n)
Wiring cover
Remove the protective bushes to connect cables. (FR-A846-00470(18.5K) or
lower)
(o)
Front cover
Remove this cover for the installation of the product, installation of a plug-in
(communication) option, RS-485 terminal wiring, switching of the voltage/current
input switch, etc. For the FR-A846-01800(55K) or higher, the front cover for the
control circuit inspection and the front cover for the main circuit inspection can be
individually removed.
(p)
Operation panel (FR-DU08-01) Operates and monitors the inverter.
(q)
Fan cover
Remove this cover for replacement of the cooling fan. (FR-A846-00250(7.5K) or
higher)
(r)
Cooling fan
Cools the inverter. (FR-A846-00250(7.5K) or higher)
(s)
Internal fan
Cools the inverter.
(t)
Bracket
Fixes the internal fan.
(u)
Protective cover
Protects the fan to avoid contacting the wiring. (FR-A846-00250(7.5K) to
00470(18.5K))
(s)
(t)
(u)
(m)
(n)
(a)
(f)
(h)
(k)
(j)
(g)
(o)
(p)
(r)
(q)
(b)
(c)
(e)
(i)
(l)
(d)
Front cover for
control circuit
inspection
Front cover for
main circuit
inspection
Front cover of the
FR-A846-01800(55K) or higher