44
I/O SIGNAL LIST
6.2 I/O Signal List
6.2.1 I/O signal when CC-Link Ver.1 one station (FR-A5NC compatible) is
occupied (Pr. 544 = 0)
(1) Remote I/O (32 points)
Device
No
Signal
Refer
to
Page
Device
No
Signal
Refer
to
Page
RYn0
Forward rotation command
RXn0
Forward running
RYn1
Reverse rotation command
RXn1
Reverse running
RYn2
High-speed operation command (terminal
RH function)
RXn2
Running (terminal RUN function)
RYn3
Middle-speed operation command
(terminal RM function)
RXn3
Up to frequency (terminal SU function)
RYn4
Low-speed operation command
(terminal RL function)
RXn4
Overload alarm (terminal OL function)
RYn5
Jog operation command (terminal Jog
function)
RXn5
Instantaneous power failure (terminal IPF
function)
RYn6
Second function selection (terminal RT
function)
RXn6
Frequency detection (terminal FU
function)
RYn7
Current input selection (terminal AU function)
RXn7
Error (terminal ABC1 function)
RYn8
Selection of automatic restart after instantaneous
power failure (terminal CS function)
RXn8
(terminal ABC2 function)
RYn9
Output stop
RXn9
Pr. 313 assignment function (DO0)
RYnA
Start self-holding selection (terminal
STOP function)
RXnA
Pr. 314 assignment function (DO1)
RYnB
Reset (terminal RES function)
RXnB
Pr. 315 assignment function (DO2)
RYnC
Monitor command
RXnC
Monitoring
RYnD
Frequency setting command (RAM)
RXnD
Frequency setting completion (RAM)
RYnE
Frequency setting command (RAM, EEPROM)
RXnE
Frequency setting completion (RAM, EEPROM)
RYnF
Instruction code execution request
RXnF
Instruction code execution completion