4

Product Specifications

   

For detail specifications which do not appear in the specification comparison charts contained herein, see the user's 
manual supplied with the MELSEC-Q Series Module you use. Also, check that the specifications of the 
connected devices meet the specifications of the MELSEC-Q Series Module.

 

   

Conversion Adapter 

Model 

Before replacement 

Module Model 

No. of 
output 
points 

After replacement 

MELSEC-Q Series 

Module Model 

 

Conversion 

Adapter 

Weight (g) 

No. of 

modules 

ERNT-1Y2Q904914 

JAMSC-B2904 16 

QY18A 

280 

JAMSC-B2914 16 

 

TB1

MEMOCON-SC 

GL Series

(2000 Series I/O)

Module

Internal circui t diagram of 
ERNT-1Y2Q904914

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18 TB19

TB20 TB21

TB22 TB23

TB24 TB25

TB26 TB27

TB28 TB29

TB30 TB31

TB32 TB33

TB34 TB35

TB36 TB37

TB38

MELSEC-Q 

Series

Module

(Slot No.)

MELSEC-Q 

Series

Module

(Slot No. +1)

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18

L

TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9

TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38

100 to 240VAC

TB1

TB2

TB3

TB4

TB5

TB6

TB7

TB8

Y00

TB9

TB10

TB11

TB12

TB13

TB14

TB15

TB16

TB17 Open

TB18 Open

Y01

Y02

Y03

Y04

Y05

Y06

Y07

Output

1

Output

2

Output

3

Output

4

Output

5

Output

6

Output

7

Output

8

Output

9

Output

10

Output

11

Output

12

Output

13

Output

14

Output

15

Output

16

TB2

TB3

TB4

TB5

TB6

TB7

TB8

Y00

TB9

TB10

TB11

TB12

TB13

TB14

TB15

TB16

TB17 Open

TB18 Open

Y01

Y02

Y03

Y04

Y05

Y06

Y07

Open
Open

24V

0V
FG
FG

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

FG terminal

 is not requierd.

Terminal 

No.

Signal

Name

Signal

Name

Terminal 

No.

Signal

Name

TB1

*1

*2

External power 

supply is not 

requierd.

Do not use 

110VDC.

Terminal 

No.

 

 

Precautions for wiring

 

 

External power supply connected to the terminal numbers TB35 and TB36 on the 
MEMOCON-SC GL Series (2000 Series I/O)-side terminal block becomes unnecessary. 
However, that leaving the terminals connected will not cause a problem because the wire is 
not connected inside the Conversion Adapter.

 

 

FG terminal connected to the terminal numbers TB37 and TB38 on the MEMOCON-SC GL 
Series (2000 Series I/O)-side terminal block becomes unnecessary. However, that leaving 
the terminals connected will not cause a problem because the wire is not connected inside 
the Conversion Adapter.

 

< Specification Comparison > 

Model 

 

Specifications 

MEMOCON-SC GL Series 

(2000 Series I/O) 

MELSEC-Q Series 

JAMSC-B2904 JAMSC-B2914 

QY18A 

No. of output points 

16 points 

16 points 

8 points 

Rated switching 
voltage/current 

DC110V, 0.3A 
AC220V, 0.5A 

DC110V, 0.3A 
AC220V, 0.5A 

24VDC, 2A (resistive load)/point 

240VAC, 2A (cos

φ

=1)/point 

8A/unit 

Minimum switching load 

5VDC, 1mA 

24VDC, 10mA 

5VDC, 1mA 

Maximum switching load 

110VDC 0.5A 

220VAC 15A 

110VDC 0.5A 

220VAC 15A 

125VDC 
264VAC 

Response 
time 

OFF to ON 

6ms or less 

6ms or less 

10ms or less 

ON to OFF 

4ms or less 

4ms or less 

12ms or less 

Surge suppressor 

None 

None 

None 

Fuse None 

None 

None 

Isolation method 

Relay isolation 

Relay isolation 

Relay isolation 

Common terminal arrangement 

All points independent 

All points independent 

All points independent 

External connection system 

38-point 

terminal block 

38-point 

terminal block 

18-point 

terminal block 

Make sure the 

       

  section of the above table meets the specification of the machines and equipment connected to the 

MELSEC-Q Series Module. 

 

5

Mounting and Installation 

5.1

 

Handling Precautions 

(1) Before attempting to install the Unit or carry out the necessary wiring, make certain that the 

external power supply, used in the system, is shut off on all three phases. Failure to do so may 
result in electric shock or damage to the product. 

(2) Do not touch live terminals. There is a danger of electric shock or malfunction.

 

(3) Do not modify the Conversion Adapter or take it apart. Doing so will cause failure, malfunction, 

personal injury, or fire.

 

(4) Do not touch the energized part of the Conversion Adaptor directly. Contact will cause 

malfunction or failure in the system.

 

(5) Fasten the Conversion Adapter and the Mounting Bracket securely with retaining screws, and 

tighten the screws by applying torque within specified limits. Loose screws can lead to the 
dropping of the Conversion Adapter, or Mounting Bracket, possibly causing breakage thereof.   
Excessive tightness of the screws can lead to breakage of the screws, Converter Adaptor, 
Mounting Bracket, or MELSEC-Q Series Module, possibly causing the dropping, shorting, and 
malfunction thereof.

 

(6) Use care to prevent foreign materials including cuttings and wiring debris from entering the 

Conversion Adapter or the MELSEC-Q Series Module. These will be cause for fire, failure or 
malfunction.

 

(7) Do not drop the Conversion Adapter and Mounting Bracket or do not give a strong impact to it. 

This will cause damage.

 

5.2

 

Use Precautions

 

Item Use 

Precautions 

Depth 

dimension 

The depth dimension required for installation is 141.6mm. Check the installation 
condition. 

MELSEC-Q Series

Renewal Tool

+

MEMOCON-SC GL Series

(2000 Series I/O)

UP

31.6mm

Unit:mm

110

141.6

 

*

The each depth dimension is measured from the panel surface. 

MEMOCON-SC GL Series (2000 Series I/O): Base Unit + Input/output  
Terminal block, MELSEC-Q Renewal Tool: Base Unit + Input/output 
 Conversion A Terminal block   

 

Interference 

of the terminal 

block 

When mounting either of the following Conversion Adapters on the right side of the 
Conversion Adapter, leave one slot open between them so that the Conversion 
Adapter does not interfere with the terminal block of the existing module. 
 

Conversion Adapters : ERNT-1Y2Q500, ERNT-1JQ33S 

 

Conversion Adapter

Terminal block of the 

MEMOCON-SC GL Series 

(2000 Series I/O)

The Conversion Adapter interferes with the terminal block 

of the MEMOCON-SC GL Series (2000 Series I/O).

Leave one slot open.

Input / Output 

Module

Conversion Adapter

ERNT-1Y2Q500

ERNT-1JQ33S

 

5.3

 

Installation Environment

 

The installation environment is the same as MELSEC-Q Series CPU Module to use. Refer to the user's 
manual of the MELSEC-Q Series CPU Module to be used.

 

 

6

Part Names and Installation Method 

 

Mounting Bracket (Conversion Adapter accessory)

Mounting Bracket
M3.5×6(Conversion Adapter accessory)

Conversion Adapter installation screw

M3×30

Conversion Adapter

bottom installation

screw

M3×20

Conversion Adapter
Anchor Base

Conversion Adapter

Conversion Adapter Anchor Base installation screw
M4×8(Conversion Adapter Anchor Base accessory)

Terminal block
installation crew(M3)

MELSEC-Q Series Module

Precaution

3

1

2

2

2

2

4

4

4

4

5

5

6

6

MEMOCON-SC
GL Series
(2000 Series I/O)
Terminal block

 

6.1

 

Installation Method

 

  Secure the Conversion Adapter Anchor Base to the Base Adapter or control panel using the 

Conversion Adapter Anchor Base installation screws (M4 

 8) provided as an accessory. (Two 

end locations) 

   

Remove the terminal block attached with the MELSEC-Q Series Module after loosening the 
terminal block installation screws (2 places top and bottom).

 

 

Secure the Mounting Bracket to the Q Series Module using the Mounting Bracket fixing screws 
[M3.5 

 6 (Conversion Adapter accessory); four upper/lower locations]. 

    Mount the Conversion Adapter onto the Mounting Bracket. 

    Secure the Conversion Adapter using the Conversion Adapter installation screws (M3 

 30; 4 

locations). 

Precaution 

 

Before tightening the installation screws, check that the Conversion Adapter has been 
securely installed on the MELSEC-Q Series Module. Tightening the screws in floating-off state 
or tilting state will damage the Conversion Adapter installation screws and the Mounting 
Bracket. 

 

    Secure the Conversion Adapter using the Conversion Adapter bottom installation screw (M3 

 

20; 2 location). 

    Secure the terminal block of the MEMOCON-SC GL Series (2000 Series I/O) to the Conversion 

Adapter with the terminal block installation screws (M3; two upper/lower locations). 

6.2

 

Tightening Torque 

Tighten the installation screws to the specified torque below. An inappropriate tightening torque could 
cause the product to fall or result in a short circuit, product failure or malfunction.

 

Screw Location 

Tightening Torque Range

 

Conversion Adapter Anchor Base installation screw (M4×8)

 

1.39 to 1.89N

Mounting Bracket fixing screw (M3.5×6)

 

0.68 to 0.92N

Conversion Adapter installation screw (M3×30)

 

0.43 to 0.57N

Conversion Adapter bottom installation screw (M3×20)

 

Terminal block installation screw (M3)

 

0.5 to 0.6N

 

7

External Dimensions 

Unit

mm 

20

4

41

.9

55.2

18.9

92

53.5

Conversion Adapter

Mounting Bracket

 

 

Duplication Prohibited 

This manual may not be reproduced in any form, in part or in whole, without written permission from 
Mitsubishi Electric Engineering Company Limited. 

©2016 MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED ALL RIGHTS RESERVED 

 

MELSEC is a registered trademark of Mitsubishi Electric Corporation. 
MEMOCON is a registered trademark or a trademark of YASKAWA Electric Corporation. 

 

Product Warranty Details 

Please confirm the following product warranty details prior to product use. 

Gratis Warranty Terms and Gratis Warranty Range 

If any fault or defect (hereinafter referred to as “Failure”) attributable to Mitsubishi Electric Engineering 
Company Limited (hereinafter referred to as “MEE”) should occur within the gratis warranty period, MEE 
shall repair the product free of charge via the distributor from whom you made your purchase. 

 

Gratis Warranty Period 

The gratis warranty period of this product shall be one (1) year from the date of purchase or delivery 
to the designated place. 
Note that after manufacture and shipment from MEE, the maximum distribution period shall be six 
(6) months, and the gratis warranty period after manufacturing shall be limited to eighteen (18) 
months. 
In addition, the gratis warranty period for repaired products shall not exceed the gratis warranty 
period established prior to repair. 

 

Gratis Warranty Range 

The gratis warranty range shall be limited to normal use based on the usage conditions, methods 
and environment, etc., defined by the terms and precautions, etc., given in the instruction manual, 
user’s manual and caution labels on the product. 

Warranty Period after Discontinuation of Production 

(1) MEE shall offer product repair services (fee applied) for seven (7) years after production of the 

product has been discontinued. Discontinuation of production shall be reported via distributors. 

(2)  Product supply (including spare parts) is not possible after production has been discontinued. 

Exclusion of Opportunity Loss and Secondary Loss from Warranty 
Liability 

Regardless of the gratis warranty period, MEE shall not be liable for compensation for damages arising 
from causes not attributable to MEE, opportunity losses or lost profits incurred by the user due to Failures 
of MEE products, damages or secondary damages arising from special circumstances, whether foreseen 
or unforeseen by MEE, compensation for accidents, compensation for damages to products other than 
MEE products, or compensation for other work carried out by the user. 

Changes in Product Specifications 

The specifications given in the catalogs, manuals and technical documents are subject to change without 
notice. 

 

This document is a new publication, effective November 2016. Specifications are subject to change 
without notice. 

 

Developed November 2016 

50CM-D180259-B

 

MELSEC-Q Series terminal block installation screw
(Secure it in two places, top and bottom.)

*1

 

*2

 

Отзывы: