Mitsubishi City Multi PCFY-P VKM-E Скачать руководство пользователя страница 7

7

5.5. Airfl ow direction setting

<To Change the Airfl ow’s Up/Down Direction>

  With the unit running, press the Airfl ow Up/Down button 

6

 as necessary.

•  Each press changes the direction. The current direction is shown at 

6

.

•  The change sequence, and the available settings, are as follows.

* Note that during swing operation, the directional indication on the 

screen does not change in sync with the directional vanes on the unit.

*  Some models do not support directional settings.
*1. For MA remote controller only, other remote controllers display the 

same as 4steps model.

*2. Airfl ow direction setting <Auto>
     COOL/FAN/DRY : Setting 1 (Horizontal), HEAT : Setting 5 (Downward 5)

Airfl ow

Display

5 steps

model*1

4 steps

model

(PMFY)

4 steps

model

(PKFY-BM)

1

2

3

4

(Horiz.)

Swing

Swing

Auto

1

2

3

4

5

Note:

 The number of available fan speeds depends on the type of unit 

connected. Note also that some units do not provide an “Auto” 
setting.

 In the following cases, the actual fan speed generated by the unit 

will differ from the speed shown the remote controller display.
1. While the display is showing “STAND BY” or “DEFROST”.
2. When the temperature of the heat exchanger is low in the heat-

ing mode. (e.g. immediately after heating operation starts)

3. In HEAT mode, when room temperature is higher than the tem-

perature setting.

4. When the unit is in DRY mode.

5.2. Mode select

 

Press the operation mode (

) button 

2

 and select the op-

eration mode 

2

.

 Cooling mode

 Drying mode

 Fan mode

 Heating  mode

 Automatic (cooling/heating) mode

Automatic operation

 According to a set temperature, cooling operation starts if the room 

temperature is too hot and heating operation starts if the room tem-
perature is too cold.

 During automatic operation, if the room temperature changes and 

remains 1.5 °C or more above the set temperature for 3 minutes, the 
air conditioner switches to cooling mode. In the same way, if the room 
temperature remains 1.5°C or more below the set temperature for 3 
minutes, the air conditioner switches to heating mode.

5. Operation

Cooling mode

3 minutes (switches from 
heating to cooling)

Set tempe1.5°C

Set temperature

Set temperature -1.5°C

3 minutes (switches from cool-
ing to heating )

 Because the room temperature is automatically adjusted in order to 

maintain a fi xed effective temperature, cooling operation is performed 
a few degrees warmer and heating operation is performed a few de-
grees cooler than the set room temperature once the temperature is 
reached (automatic energy-saving operation).

5.3. Temperature setting

  

To decrease the room temperature:

 Press   

button 

to set the desired temperature.

 

The selected temperature is displayed at 

3

.

 

 To increase the room temperature:

 Press   

button 

to set the desired temperature.

 

The selected temperature is displayed at 

3

.

•  Available temperature ranges are as follows:
 

Cooling/Drying: 

19 - 30 °C

 

Heating: 

17 - 28 °C

 

Automatic: 

19 - 28 °C

•  The display blinks either 8°C - 39°C to inform you if the room tempera-

ture is lower or higher than the displayed temperature.

5.4.  Fan speed setting

 Press the Fan Speed button 

5

 as many times as necessary while the 

system is running.
•  Each press changes the force. The currently selected speed is 

shown at 

5

.

•  The change sequence, and the available settings are as follows.

FAN SPEED

Display

4-speed

+

Auto *

3-speed

+

Auto *

4-speed 

model

       

 

Speed 1 

         Speed 2           Speed 3           Speed 4

Speed 1

Speed 2

Speed 3

Speed 4

Auto

Automatic fan speed setting (For wireless remote controller)

It is necessary to set for wireless remote controller only when 
automatic fan speed is not set at default setting.
It is not necessary  to set for wired remote controller with automatic 
fan speed at default setting.

1

 Press the SET button with something sharp at the end.

Operate when display of remote controller is off.

 

MODEL SELECT

 

blinks and Model No. is lighted

 

A

.

2

 Press the AUTO STOP 

 button.

 

blinks and setting No. is lighted

 

B

.

(Setting No.01: without automatic fan speed )

3

 Press the temp.

 

 

buttons to set the setting No.02.

    

(Setting No.02:with automatic fan speed ) 

If you mistook the operation, press the ON/OFF 

 button and oper-

ate again from procedure 

2

.

4

 Press the SET button with something sharp at the end.

MODEL SELECT

 

and Model No. are lighted for 3 seconds, then turned off.

ON/OFF

  TEMP

RESET

SET

CLOCK

MODEL SELECT

FAN

VANE

TEST RUN

AUTO STOP

AUTO START

h

min

LOUVER

MODE

CHECK

B

A

3

2

14

*  For MA remote controller only.
   Automatic fan speed setting is necessary for wireless remote controller.

Speed 1

Speed 2

Speed 3

Auto

1

2

3

4

(Horiz.)

BG79U322H08̲EN.indd   7

BG79U322H08̲EN.indd   7

2008/10/14   9:52:42

2008/10/14   9:52:42

Содержание City Multi PCFY-P VKM-E

Страница 1: ...rrect use please read this operation manual thoroughly before operating the air conditioner unit FOR USER Air Conditioners For Building Application INDOOR UNIT PKFY P VBM E PKFY P VHM E PCFY P VKM E P...

Страница 2: ...contact your dealer Never insert fingers sticks etc into the intakes or outlets If you detect odd smells stop using the unit turn off the power switch and consult your dealer Otherwise a breakdown ele...

Страница 3: ...hr 100 hr 100 hr 2 Parts Names PCFY P VKM E Ceiling Suspended PKFY P VBM E Wall Mounted PMFY P VBM E 1 way Ceiling Cassette Filter Air intake Louver Air outlet Vane Filter Air inlet Louver Air outlet...

Страница 4: ...n Set Temperature buttons Down Up Mode button Return button Set Time buttons Timer On Off button Set Day button Opening the door ON OFF button Fan Speed button Filter button Enter button Test Run butt...

Страница 5: ...n do not get the remote controller wet or leave it in a location with high hu midity To avoid misplacing the remote controller install the holder included with the remote controller on a wall and be s...

Страница 6: ...Set the current day of the week or time Standard Control Screens View and set the air conditioning system s op erating status Timer Monitor View the currently set timer weekly timer sim ple timer or A...

Страница 7: ...switches from cool ing to heating Because the room temperature is automatically adjusted in order to maintain a fixed effective temperature cooling operation is performed a few degrees warmer and hea...

Страница 8: ...nday Start the air conditioner at 8 30 with the temperature set to 23 C Operation 2 settings for every day Turn off the air conditioner at 10 00 C SUN ON WEEKLY Shows the selected operation ON or OFF...

Страница 9: ...ON timer The air conditioner will start operation when the specified number of hours has elapsed OFF timer The air conditioner will stop operation when the specified number of hours has elapsed 4 Wit...

Страница 10: ...countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed Available settings run from 30 minutes to 4 hours in 30 minute intervals Note 1 Weekly Timer...

Страница 11: ...type see section 8 item 4 2 1 Specifically you can use either of the following two lock types 1 Lock All Buttons Locks all of the buttons on the remote controller 2 Lock All Except ON OFF Locks all bu...

Страница 12: ...on use of clock function 3 Timer function setting WEEKLY TIMER Setting the timer type 4 Contact number setting for error situation CALL Contact number display in case of error Setting the telephone nu...

Страница 13: ...s displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting...

Страница 14: ...can be selected Press the MENU button G to change the language 1 English GB 2 German D 3 Spanish E 4 Russian RU 5 Italian I 6 Chinese CH 7 French F 8 Japanese JP Refer to the dot display table 4 2 Fun...

Страница 15: ...re cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the w...

Страница 16: ...period when the air conditioner was used under general indoor air conditions by criteria time Since the degree of dirtiness depends on the environmental con ditions clean the filter accordingly The f...

Страница 17: ...intake grille causes the intake grille to open 2 A filter with an intake grille on it can be removed by pulling the filter forward 10 Care and Cleaning PFFY P VKM E 1 Remove the catechin air filter A...

Страница 18: ...mode water may form and drip from the cool pipes and joints During heating mode water may form and drip from the heat exchang er During defrosting mode water on the heat exchanger evaporates and water...

Страница 19: ...a microcomputer according to the air flow temperature and operation time of the air conditioner Air outlet control PFFY P VKM series This unit is automatically controlled that air comes out simultaneo...

Страница 20: ...he maximum value at operation under the following condition Cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB Heating Indoor 20 C DB Outdoor 7 C DB 6 C WB PMFY P VBM E Series Model P20 P25 P32 P40 Power...

Страница 21: ......

Страница 22: ...se be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Japan BG79U32...

Отзывы: