9 For emergency
1
5
2
6
3
7
9
4
8
10
Countermeasures
Refer to "List of alarm codes" for the contents of each alarm code and its
countermeasure.
(
Refer to pages 68 to 70)
CAUTION
Surely follow the instructions of this operation manual
for the countermeasures of the troubles.
• Otherwise, it may cause injury or an electric shock due to
unexpected start.
Changing the fuse
CAUTION
Use the designated fuse.
• If any other fuses are used, it may cause a fire or an electric
shock.
Surely stop the operation of refrigeration unit with
the "Operation switch" and set the "Main switch" to
"OFF", then disconnect the battery terminal and plug
for power code to change the fuse.
• Otherwise, it may cause injury or an electric shock due to
unexpected start.
Fuses are mounted in the control box of condensing unit.
■
Single specification (TU85SAE)
F2
F4
F9
F8
F7
F6
F5
F1
2
F1
1
F1
F1
0
F3
F11
F12
F10 F3
F1 fuse holder
F1 : 20 A (operation circuit) is fixed with the fuse holder.
F2 : 15 A (Relay circuit)
F3 : 10 A (Compressor electromagnetic clutch)
F4 : 10 A (Drain hose heater A)
F5 : 15 A (Evaporator fan motor 1)
F6 : 15 A (Evaporator fan motor 2)
F7 : 15 A (Evaporator fan motor 3)
F8 : 15 A (Evaporator fan motor 4)
F9 : 30 A (Throttle solenoid)
F10 : 10 A (Output during operation)
F11 : 10 A (Output at error occurrence)
F12 : 10 A (Output at deviation from adequate temperature)
F2
F4
F9
F8
F7
F6
F5