'15 • SRK-T-175
'09•SRK-DB-087D
Current cut
Compressor lock, Compressor wiring short circuit, Compressor output is open phase,
Outdoor PCB is faulty, Service valve is closed, EEV is faulty, Compressor faulty.
*
*
Current safe stop
Overload operation, compressor
lock, overcharge
71
.
1.155Ω (U-V), 1.133Ω (V-W), 1.174Ω (W-U) or more at 20ºC
Model63
0.864Ω or more at 20
℃
Model71, 80