5
-
Item
Model
SRK56CE-S
SRC56CE-S
Cooling capacity
(1)
W
5100
Power source
1 Phase, 220-240V, 50Hz
Cooling input
kW
1.59
Running current (Cooling)
A
7.3/7.1/6.8
Inrush current
A
45.2
COP
Cooling: 3.21
Cooling
Sound level
Hi 44, Me 40, Lo 35
49
Noise level
Power level
dB
59
64
Exterior dimensions
Height
×
Width
×
Depth
mm
298
×
840
×
259
640
×
850
×
290
Color
Cool white
Stucco white
Net weight
kg
12
44
Refrigerant equipment
Compressor type & Q’ty
–
RM-B5120MNE5 [Rotary type]
×
1
Motor
kW
–
1.5
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Straight fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Refrigerant
(3)
kg
R410A
1.4 (Pre-Charged up to the piping length of 15m)
Refrigerant oil
R
0.7 (MA68)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
27
35
Air flow (at High)
(Cooling)
CMM
11.0
38.0
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote controller
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
12.7 (1/2
″
)
Connecting method
Flare connection
Attached length of piping
Liquid line: 0.54 m
Gas line : 0.47 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2 m (3 cores with earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter
×
1, Photocatalytic washable deodorizing filter
×
1)
Optional parts
–
Notes (1) The data are measured at the following conditions.
Model SRK56CE-S (Indoor unit)
SRC56CE-S (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25 m, add 20 g refrigerant per meter.
Operation data
(2)
Refrig
erant
piping
Compressor: Overheat protection, Serial signal error protection, Indoor fan motor error protection, Frost
protection
The piping length is 7.5m.