
-
-
'15 • SRK-T-172
(4) Troubleshooting procedure (If the air-conditioner runs)
NO
NO
NO
NO
YES
YES
YES
YES
Note () Even in cases where only intermittent stop data are generated, the air conditioning system is normal. However, if the same protective operation recurs
repeatedly ( or more times), it will lead to customer complaints. Judge the conditions in comparison with the contents of the complaints.
Confirm the contents of the customer complaint.
Check the self-diagnosis display.
Eliminate the cause of the trouble and perform an
operation check.
Replace the faulty component, then perform an
operation check.
Identify the faulty component by using the check
procedure corresponding to the content of the trouble.
The cause of the trouble can
be specifically identified.
See below.
NO
NO
NO
NO
YES
YES
YES
YES
(5) Self-diagnosis table
When this air-conditioner performs an emergency stop, the reason why the emergency stop occurred is displayed by the flashing of
display lights. If the air-conditioner is operated using the remote control minutes or more after the emergency stop, the trouble
display stops and the air-conditioner resumes operation.
()
Notes () The air-conditioner cannot be restarted using the remote control for minutes after operation stops.
When a heat exchanger sensor wire disconnection is detected while operation is
stopped. (If a temperature of –20ºC or lower is detected for 15 seconds, it is
judged that the wire is disconnected.)
(Not displayed during operation.)
When a room temperature sensor wire disconnection is detected while operation
is stopped. (If a temperature of –20ºC or lower is detected for 15 seconds, it is
judged that the wire is disconnected.)
(Not displayed during operation.)
• Broken heat exchanger sensor
wire, poor connector
connection
• Indoor PCB is faulty
• Broken room temperature
sensor wire, poor connector
connection
• Indoor PCB is faulty
When conditions for turning the indoor unit’s fan motor on exist during air-
conditioner operation, an indoor unit fan motor speed of 300 min
-1
or lower is
measured for 30 seconds or longer. (The air-conditioner stops.)
• Defective fan motor, poor
connector connection
ON
1-time
flash
ON
2-time
flash
ON
6-time
flash
When there is an emergency stop caused by trouble in the outdoor unit, or the
input current value is found to be lower than the set value.
(The air-conditioner stops.)
• Broken compressor wire
• Compressor blockage
• 52C relay in indoor PCB is faulty
• Improper wire connection
between indoor and outdoor
2-time
flash
ON
Indoor unit display panel
Cause
Display (flashing) condition
RUN
light
TIMER
light
Heat exchanger
sensor error
Room
temperature
sensor error
Indoor fan
motor error
Trouble of
outdoor unit
Description
of trouble
All manuals and user guides at all-guides.com
all-guides.com
Содержание SRK10CRS-S
Страница 2: ...All manuals and user guides at all guides com ...
Страница 3: ... 15 SRK T 172 TECHNICAL MANUAL All manuals and user guides at all guides com ...
Страница 60: ... 58 All manuals and user guides at all guides com ...
Страница 64: ... 62 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Страница 68: ... 66 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Страница 72: ... 70 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com ...
Страница 76: ... 74 15 SRK T 172 4 6 10641 All manuals and user guides at all guides com a l l g u i d e s c o m ...