Mitsubishi Heavy Industries RCN-E-E Скачать руководство пользователя страница 3

2

 -

If the unit has been submerged under water due 
to a natural disaster such as flood or typhoon, 
consult your dealer before using it again.

If you use it as it stands, it may lead to failure, electric shock or fi re.

If any abnormal symptom (scorched fl avor etc.) is 
found, cut off the power and stop the operation.
Then consult your dealer. 

If you use it as it stands, it may lead to failure, electric shock or fi re.

One of the causes of poor cooling or poor heating may 
be refrigerant leakage. Please consult your dealer.

If  the  repair  requires  additional  refrigerant,  determine 
the ser vice with the ser vice staf f. The refrigerant of air 
conditioner is not toxic. Normally the refrigerant does not 
leak. But if it leaks and contacts fi re such as fan heater, space 
heater or cooking heater, it may produce toxic chemicals.

Do not insert fi ngers  or  sticks  even  if  air  blower 
does not operate.

It may suddenly operate and cause injuries.

 CAUTION

Do not use for particular purpose such as the 
storage of food, animals and plants, precision 
apparatus and arts etc.

Storage goods may degrade.

Do not operate the button with wet hand.

It may cause electric shock.

When a burning appliance is used together with 
the unit, ventilate frequently.

If ventilation is not sufficient, it may cause oxygen 
defi ciency accident.

D o not plac e a burning a p plianc e wh e r e t h e 
airfl ow from the unit is directly blown.

It may cause the imperfect combustion of the equipment.

Make sure that the unit installation foundation is 
not damaged due to long-term use.

If it is left to stand, the unit may fall down causing injury.

Do not wash the unit with water, nor place a vase 
with water on the unit.

It may cause electric shock or ignition.

Do not install the unit where the airfl ow is directly 
blown to animals and plants.

They may suffer from adverse effect.

Before cleaning, make sure to stop operation and 
cut off the power.

The fan inside rotates at high speeds.

Make sure to use proper size of fuse.

Using steel wire or copper wire may lead to failure or fi re.

Do not store a fl ammable spray etc. near the unit, 
nor blow directly to the unit.

It may lead to fi re.

Before maintenance, make sure to stop operation 
and cut off the power.

The fan inside rotates at high speeds.

When the unit isn’t used for a long-term, cut off 
the power.

The accumulation of dirt may lead to heat generation or fi re.
But,  before  resuming  the  operation,  turn  on  the  unit  for  six 
hours beforehand to save harmless.

D o n o t p l a c e a ny o t h e r e l e c t r i c a p p l i a n c e s o r 
household goods below or around the air conditioner.

Dripping from the unit may lead to failure or contamination.

SAFETY PRECAUTIONS

Please read these “SAFETY PRECAUTIONS” before 
s t a r t i n g t o u s e t h i s p r o d u c t a n d u s e t h e p r o d u c t 
appropriately according to the instructions.
The precautions provided here are classified into “
DANGER” and “

 CAUTION”. The “

 DANGER” sections 

describe potentially hazardous situations that may lead to 
serious outcomes such as death and sericus injuries if the 
product is mishandled. Note, however, that depending on 
the situation, the items listed in the “ CAUTION” sections do 
also have the potential of causing serious outcomes. Both 
warnings and cautions provide you important information 
related to safety ; please make sure to observe them.
The symbols used throughout the main tex t of this 
manual have the following meaning.

 marks mean danger, alarm, and caution. The 

specifi ed prohibited item is described in the triangle. 
The left mark means “Shock hazard alarm”.

 marks mean prohibited items. The specified 

prohibited item is described in the circle or in the 
vicinage.

 marks mean compulsory action or instruction. 

The specifi ed prohibited item is described in the 
circle. The left mark means “Earth is needed”.

After you have read the manual, always store it where 
other users can refer to at any time. If a new owner takes 
over the system, make sure to pass this manual. 

„

„

„

„

INSTALLATION PRECAUTIONS

 DANGER

Make  sure  to  have  the  installation  done  by  your 
dealer or a specialist.

If you install by yourself and the unit is not properly 
installed, water leakage, electric shock, fire and 
injuries caused by the drop of the unit may occur.

The preventive measures that the density of leaked 
refrigerant does not exceed the limit is necessary in 
case of installing the unit in a small room.

The leakage of refrigerant may cause oxygen deficiency 
accident. Consult your dealer for the measures.

 CAUTION

Make sure to perform grounding work.

Do not connect grounding wire to any gas pipe, water 
pipe, conductor rods or telephones.Incomplete grounding 
may cause electric shock through leakage of electricity.

Make sure to mount a leakage breaker.

Otherwise electric shock may occur. Please consult 
your dealer or a specialist for the mounting.

Do not mount where fl ammable gas leakage can 
happen.

If leaked gas stagnates around the unit, the gas may 
cause fi re.

Make  sure  to  layout  the  drain  pipe  so  that  the 
water is completely drained.

Otherwise, water may leak and wet household goods.

OPERATION PRECAUTIONS

 DANGER

Do not expose yourself directly to cooled air for a 
long time or cool too much.

It may be cause of deconditioning or health disorder.

Do not insert fi ngers or sticks into the air inlet or 
outlet grilles.

It may cause injuries because of the fan rotating at 
high speed.

PJZ012A055̲body̲1221.indd   2

PJZ012A055̲body̲1221.indd   2

2007/12/25   17:59:07

2007/12/25   17:59:07

Содержание RCN-E-E

Страница 1: ...reiche mit einer Netzstromversorgung von 50 Hz Questo condizionatore d aria e conforme alla Direttiva EMC 89 336 EEC 92 31 EEC 93 68 EEC LV Direttiva 2006 95 EC Il marchio CE è applicabile alla fascia di alimentazione 50 Hz Deze airconditioner voldoet aan EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC LV Directive 2006 95 EC CE markering is van toepassing op het gebied met een net stroom van 50 Hz E...

Страница 2: ...t will help you when you have questions or problems Apart from the remote controller operation be sure to read the instruction manual enclosed with the indoor unit TABLE OF CONTENTS SAFETY PRECAUTIONS 2 INDICATION BOARD 4 BACK UP BUTTON 4 NAMES AND FUNCTIONS OF REMOTE CONTROLLER BUTTON 5 HOW TO OPERATE 6 CURRENT TIME SETTING PROCEDURE 6 ON TIMER OPERATION 7 OFF TIMER OPERATION 7 PROGRAM TIMER OPER...

Страница 3: ...ditioner Dripping from the unit may lead to failure or contamination SAFETY PRECAUTIONS Please read these SAFETY PRECAUTIONS before starting to use this product and use the product appropriately according to the instructions The precautions provided here are classified into DANGER and CAUTION The DANGER sections describe potentially hazardous situations that may lead to serious outcomes such as de...

Страница 4: ...e water heater etc near the indoor unit or remote control If a Vapor generating appliance is used near them it may lead to water drop causing electric leakage or short circuit Do not use the unit where powder or fiber is floating Fine powder or fiber passing through the air filter may stagnate inside the unit and lead to electric leak or short circuit Do not place objects under the unit which must...

Страница 5: ... button can start and stop the air conditioner Refer to bellow RUN CHECK LAMP The lamp blinks are indicated in 3 patterns as follows z Lit up in green During operation z Blinked in green PREPARATION OF HEATING during heating mode Refer to Page 10 z Blinked in red An irregularity occurs in the air conditioner Refer to Page 9 Press the back up button The air conditioner starts Set items are as follo...

Страница 6: ...eries when the remote controller is not used for a long time The recommendable effective period of a battery is about 6 to 12 months It depends on the usage The recommendable effective period is printed on the battery T h i s m ay b e s h o r t e r d u e t o manufacturing time of the unit However the battery may be still working in order after expiry date When the batteries are inserted each opera...

Страница 7: ... on the remote controller 2 Press MODE button Current operation mode is indicated with the marks besides the operation mode icons The mode will change in the following order by pressing the button AUTO COOL HEAT FAN DRY 3 Press TEMP button Set the room temperature by pressing or bbutton 4 Press FAN SPEED button HI MED LO FAN SPEED can be changed in order 5 Press AIR FLOW button Effective AIR FLOW ...

Страница 8: ...hen the air conditioner stops The air conditioner starts to operate OFF TIMER can be set only in case the air conditioner is in operation 2 Press OFF TIMER button OFF TIMER display blinks 3 Press or button to adjust to PM 9 00 Displayed time will be changed by 10 minutes by pressing the buttons 4 Press OFF timer button OFF TIMER display changes from blinking to steady lighting and the setting is c...

Страница 9: ...tinuous movement of display Recommended air frow direction position when fixed A B C D COOL DRY AUTO HEAT FOR COMFORTABLE USE Clean the filter frequently If the filter is clogged The cooling heating capacity will get reduced Moreover it leads to waste of electricity and larger operation noise It may cause failure Dew may form and drop during cooling Do not block the inlet and outlet grilles of the...

Страница 10: ...ess the ON OFF button to stay the air conditioner on the stop mode NOTICE The outside unit No is not displayed Address No Error code CHECK MODE WHEN THE FILTER CHECK LAMP RED IS LIT Clean the filter When cumulative running time reaches 120 hours long flashing light light for 2 seconds wink out for 1 second is shed from the filter check lamp red After cleaning of filter press the FILTER button on t...

Страница 11: ...ing capacity The heating efficiency of heat pump type air conditioner decreases as the outside temperature becomes lower If the capacity of air conditioner for heating is not sufficient please use other heating device Time required until the room temperature increases A heat pump type air conditioner circulates warm air to warm the entire room so it takes a while to rise up the room temperature It...

Страница 12: ...SUBISHI HEAVY INDUSTRIES EUROPE LTD AIR CONDITIONER DIVISION 3rd Floor Thavies Inn House 3 4 Holborn Circus London EC1N 2HA ENGLAND Phone 44 0 20 7842 8171 Fax 44 0 20 7842 8104 MITSUBISHI HEAVY INDUSTRIES AUSTRALIA PTY LTD 81 Railway Street Rockdale NSW 2216 Australia Phone 61 0 2 9597 7977 Fax 61 0 2 9597 7304 ...

Отзывы: