Mitsubishi Heavy Industries DXK09Z6-S Скачать руководство пользователя страница 3

EN-1

Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD. 
Air-Conditioner. To get the best long-lasting performance, please read and follow this user’s manual 
carefully before using your air-conditioner. After reading, please store the manual in a safe place 
and refer to it for operational questions or in the event of any irregularities.

ENGLISH

This Product contains fluorinated greenhouse gases. 
Do not vent R410A into the atmosphere: R410A is a fluorinated greenhouse gas with a Global 
Warming Potential (GWP) = 2088.
Refer to a label on outdoor unit for the weight of fluorinated greenhouse gas and CO

2

 equivalent.

Safety precautions ..........................................2

Tips for effective operation .............................5

Name of each part and its function .................6

Remote control ...............................................8

Operation failure with the remote control........8

Temporary run operation ................................8

Operation and display section for 
remote control.................................................9

Current time setting ........................................9

AUTO mode operation ..................................10

FAN SPEED .................................................10

COOL/HEAT/DRY/FAN mode operation ...... 11

Air-conditioner operation temperature 

range ............................................................ 11

Characteristics of HEAT mode operation ..... 11

Air

fl

 ow direction adjustment..........................12

SLEEP TIMER operation ..............................13

OFF TIMER operation ..................................13

ON TIMER operation ....................................14

SLEEP TIMER + ON TIMER operation ........14

PROGRAM TIMER operation .......................15

HIGH POWER/ECONOMY operation ..........16

SELF CLEAN operation................................17

Auto restart function .....................................17

Maintenance .................................................18

Proper installation .........................................20

Troubleshooting  ...........................................20

Contact your dealer ......................................20

Notice ...........................................................21

Self diagnosis function..................................22

contents

Your air-conditioner is marked with this symbol. It means that waste electrical and 
electronic equipment (WEEE as in directive 2012/19/EU) should not be mixed with 
general household waste. Air-conditioner should be treated at an authorized treat-
ment facility for re-use, recycling and recovery and not be disposed of in the munici-
pal waste stream. Please contact the installer or local authority for more information.

This symbol printed on the batteries attached to your air-conditioner is information 
for end-users according to the EU directive 2006/66/EC article 20 annex II.
Batteries, at their end-of-life, should be disposed of separately from general house-
hold waste. If a chemical symbol is printed beneath the symbol
shown above, this chemical symbol means that the batteries contain a 
heavy metal at a certain concentration. This will be indicated as follows:
Hg:mercury(0.0005%), Cd:cadmium(0.002%), Pb:lead(0.004%)
Please, dispose of batteries correctly at your local community waste 
collection or the recycling center.

The emission sound pressure level from each Indoor and Outdoor unit is under 70 dB(A).

RLC012A101_EN.indd   1

RLC012A101_EN.indd   1

10/25/2017   12:01:53

10/25/2017   12:01:53

Содержание DXK09Z6-S

Страница 1: ...el 61 2 8571 7977 Fax 61 2 8571 7992 https www mhiaa com au ORIGINAL INSTRUCTIONS MANUEL DE L UTILISATEUR CLIMATISEUR USER S MANUAL AIR CONDITIONER ANWENDERHANDBUCH KLIMAGERA T ISTRUZIONI PER L USO CONDIZIONATORE D ARIA MANUAL DEL PROPIETARIO ACONDICIONADOR DE AIRE GEBRUIKERSHANDLEIDING AIRCONDITIONING MANUAL DO UTILIZADOR APARELHO DE AR CONDICIONADO РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА...

Страница 2: ...elevant EU Directives Machinery 2006 42 EC Applied Standards Regulations EN 378 2 EN 60335 1 EN 60335 2 40 Conformity model list Indoor Unit Outdoor Unit Category Model DXC Series DXC09Z6 S DXC12Z6 S DXC15Z6 S Category Model DXK Series DXK09Z6 S DXK12Z6 S DXK15Z6 S Authorised Representative in the EU MITSUBISHI HEAVY INDUSTRIES AIR CONDITIONING EUROPE LTD 5 The Square Stockley Park Uxbridge Middle...

Страница 3: ...eration 15 HIGH POWER ECONOMY operation 16 SELF CLEAN operation 17 Auto restart function 17 Maintenance 18 Proper installation 20 Troubleshooting 20 Contact your dealer 20 Notice 21 Self diagnosis function 22 contents Your air conditioner is marked with this symbol It means that waste electrical and electronic equipment WEEE as in directive 2012 19 EU should not be mixed with general household was...

Страница 4: ... WARNING The system is for domestic and residential use If used in severe environments such as an engineering workplace the equipment may function poorly The system must be installed by your dealer or a qualified installer It is not advisable to install the system by yourself as faulty handling may cause leakage of water electric shock or fire CAUTION Do not install it where flammable gas may leak...

Страница 5: ...ls down you may get injured Do not place a flammable insecticide or paint spray near the air conditioner nor spray it directly on the system This may result in a fire Do not expose any combustion appliance directly to the air stream of the air conditioner The combustion appliance may malfunction Do not wash the air conditioner with water This could cause an electric shock Using a high pressure was...

Страница 6: ...ion may cause accidents due to oxygen deficiency Stand firmly on a stepladder or other stable object when removing the inlet panel and filters Failure to observe this may result in injury through insecure objects toppling over When you clean air conditioner stop the unit and turn off the power source Never open the panel while the internal fan is rotating Do not place objects near the outdoor unit...

Страница 7: ...nt gas is inhaled excessively it may cause deterioration of nerve function like dizziness and headache or deterioration of heart function like irregular heartbeat and heart palpitation temporarily If refrigerant unexpectedly leaks from the unit onto a fan heater stove hotplate or other heat source harmful gases could be generated Tips for effective operation Please observe the following for the mo...

Страница 8: ...R UNIT Air inlet back and side Fan Inside of the unit Model name Refrigerant pipe and electric wire Drain hose Drain hole The appearance varies by models IT MIGHT CAUSE INJURY DO NOT STEP ON TOP OF THIS UNIT WARNING DO NOT INSERT ANYTHING INTO THE AIR OUTLET IT MIGHT CAUSE INJURY DO NOT TOUCH THE ALUMINUM FINS IT MIGHT CAUSE INJURY SHARP EDGE OF FINS MOVING FAN BLADES CAUTION Don t touch the termi...

Страница 9: ...Wood screw 2 for remote control holder mounting This button can be used for turning on off the unit when a remote control is not available Page 8 Unit ON OFF button Accessories RUN light green Illuminates during operation Blinks slowly when SELF CLEAN operation 3 seconds ON 1 second OFF Blinks when airflow is stopped to prevent blowing out of cold air in heating operation 1 5 seconds ON 0 5 second...

Страница 10: ...ntrol Are the batteries running down Setting the batteries above Replace the batteries with new ones and retry the operation Operation failure with the remote control If the operation fails operate the unit with temporary run opera tion function Temporary run operation below Strictly prohibited Do not drop the remote control Handle with care Do not take remote control near high temperature places ...

Страница 11: ...This switch resets the program to default state Page 8 NOTE 2 Current time setting When inserting the batteries the current time is automatically set to time setting mode 13 00 is displayed as the current time Set the clock to the right time Example Set to 10 30 Press the ACL switch Press with the tip of a ballpoint pen etc The time display blinks and can be set to the current time Press the or bu...

Страница 12: ...EED is changed from HI to LO the sound of refrigerant may be heard NOTE Operation capacity by your choice FAN SPEED Set automatically by microcomputer AUTO Powerful operation with high capacity HI Standard operation MED Energy saving operation LO Each time the button is pressed the switch over occurs in the following order 6 5 1 0 1 6 When 6 is indicated even if the button is pressed the indicator...

Страница 13: ...unit may frost over which prevents efficient heating If this happens the automatic defrost function is activated and the heating operation stops for 5 to 15 minutes during defrosting Both indoor and outdoor fans stop and the RUN light blinks slowly 1 5 seconds ON 0 5 seconds OFF during defrosting The outdoor unit may release some steam during defrosting This is to help the defrosting process and i...

Страница 14: ... blowing COOL DRY Recommended angle of the flap when stopping When heating operation starts the flap direction is fixed at the horizontal position in order to avoid cold draft It returns to the set position when the warm air supply is started The flap direction will be controlled to the horizontal position when the room temperature reaches the set temperature and compressor stops or when defrostin...

Страница 15: ...conditioner turned off start the operation from Step 1 With the air conditioner running start from Step 2 Example You prefer it to stop 22 30 Press the ON OFF button Press the OFF TIMER button OFF TIMER display is blinking Press the or button Every time the button is pressed the display is switched in the order of 0 00 0 10 0 20 1 00 1 10 Units of ten minutes Every time the button is pressed the d...

Страница 16: ...ot Operation starts 5 to 60 minutes before the set time The timer light yellow goes out at the set time Make sure to press the button within 60 seconds from the last operation in step 2 otherwise the setting is not completed The current time is not displayed during ON TIMER operation If the ON OFF button is pressed after setting the ON TIMER the setting will be canceled NOTE SLEEP TIMER ON TIMER o...

Страница 17: ...temperature How to cancel Press the CANCEL or ON OFF button to turn off the timer display Changing of set time Set a new time by using the OFF TIMER or ON TIMER button Example Present time is 21 00 The air conditioner running When it is preferred to stop at 22 30 and then start operation at 8 00 near the set temperature First the air conditioner starts running with ON TIMER After the air condition...

Страница 18: ... following operations are set ECONOMY operation will be canceled 1 When the HI POWER ECONO button is pressed again 2 When the operation mode is changed from DRY to FAN Not operable while the air conditioner is OFF Concerning HIGH POWER operation Pressing the HI POWER ECONO button intensifies the operating power and initiates powerful cooling or heating operation for 15 minutes continuously The rem...

Страница 19: ...lluminates during SELF CLEAN operation Pressing the SLEEP button during SELF CLEAN operation cancels the SELF CLEAN operation and then the unit is set to SLEEP operation This is not a function for removing mold germs or grime that have already adhered to the unit 3 seconds 1 second ON OFF Auto restart function Auto restart function records the operational status of the air conditioner immediately ...

Страница 20: ...mage Cleaning the air inlet panel The panel can be washed with water After washing with water wipe any moisture off the panel and dry out of direct sunlight Pull up the air inlet panel forward Lightly hold the knobs both sides and lift a little to remove the panel forward If the filter is very dirty clean it with warm water approx 30 C and dry it thoroughly Standard interval is once every two week...

Страница 21: ... NOTE Cooling heating is affected by an air filter clogged up with dust etc and the operation noise becomes louder It may also use extra electricity Please clean the air filter at appropriate intervals 1 2 Remove batteries from the remote control Clean both the indoor and outdoor units Clean and reinstall the air filters Perform the fan operation for 2 to 3 hours Dry the inside of the unit 3 4 5 M...

Страница 22: ...ff the power and contact your dealer Do not put any obstruction in front of the indoor unit preventing proper ventilation and functioning Do not install the unit in any of the following places Where there is a danger of leaking flammable gases Where there is substantial splashing of oil Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfide gases are generated or...

Страница 23: ...rol signals may not be received if the signal receiver on the air conditioner is exposed to direct sunlight or other bright light If so block the sunlight or reduce the other light Moisture may form on the air outlet grills If the unit is operated for a long time in high humidity moisture may form on the air outlet grills and start dripping Fan will not stop immediately after unit operation is sto...

Страница 24: ...ht ON RUN light 2 time flash Outdoor temperature sensor error Outdoor heat exchanger sensor error Discharge pipe sensor error Broken outdoor sensor wire poor connector connection Broken heat exchanger sensor wire poor connector connection Broken discharge pipe sensor wire poor connector connection Current cut Trouble of outdoor unit Over current Power transistor error Over heat of compressor Error...

Страница 25: ...elevant EU Directives Machinery 2006 42 EC Applied Standards Regulations EN 378 2 EN 60335 1 EN 60335 2 40 Conformity model list Indoor Unit Outdoor Unit Category Model DXC Series DXC09Z6 S DXC12Z6 S DXC15Z6 S Category Model DXK Series DXK09Z6 S DXK12Z6 S DXK15Z6 S Authorised Representative in the EU MITSUBISHI HEAVY INDUSTRIES AIR CONDITIONING EUROPE LTD 5 The Square Stockley Park Uxbridge Middle...

Страница 26: ...el 61 2 8571 7977 Fax 61 2 8571 7992 https www mhiaa com au ORIGINAL INSTRUCTIONS MANUEL DE L UTILISATEUR CLIMATISEUR USER S MANUAL AIR CONDITIONER ANWENDERHANDBUCH KLIMAGERA T ISTRUZIONI PER L USO CONDIZIONATORE D ARIA MANUAL DEL PROPIETARIO ACONDICIONADOR DE AIRE GEBRUIKERSHANDLEIDING AIRCONDITIONING MANUAL DO UTILIZADOR APARELHO DE AR CONDICIONADO РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА...

Отзывы: