9

4.4  Direct commands 

(Not executable in stand-by mode. Possible only to read during BLANK.)

The direct commands are used to numerically adjust the geometrical correction and bright uniformity correction. 
When  the  computer  sends  the  command  without  adding  the  setting  value,  the  projector  returns  the  received 
command with the current setting value added as a data code. 

ITEM

Function

Data

Character

ASCII code

KEYSTONE (vertical)

KS

4Bh  53h

±40

With CURVED-adjustment : ±10

KEYSTONE (horizontal)

KSH

4Bh  53h  48H

±25

With CURVED-adjustment : ±10

KEYSTONE reset

KSRST

4Bh  53h  52h  53h  54h

CORNERSTONE LOWER RIGHT 

(vertical)

CNLRV

43h  4Eh  4Ch  52h  56h

±30

CORNERSTONE LOWER RIGHT 
(horizontal)

CNLRH

43h  4Eh  4Ch  52h  48h

±30

CORNERSTONE LOWER LEFT 
(vertical)

CNLLV

43h  4Eh  4Ch  52h  56h

±30

CORNERSTONE LOWER LEFT 

(horizontal)

CNLLH

43h  4Eh  4Ch  52h  48h

±30

CORNERSTONE UPPER RIGHT 

(vertical)

CNURV

43h  4Eh  55h  52h  56h

±30

CORNERSTONE UPPER RIGHT 
(horizontal)

CNURH

43h  4Eh  55h  52h  48h

±30

CORNERSTONE UPPER LEFT 
(vertical)

CNULV

43h  4Eh  55h  52h  56h

±30

CORNERSTONE UPPER LEFT 

(horizontal)

CNULH

43h  4Eh  55h  52h  48h

±30

CORNERSTONE reset

CKSRST

43h  4Bh  53h  52h  53h  54h

HORIZ. CURVED ARC

CVAH

43h  56h  41h  48h

±50
With KEYSTONE- or 
CORNERSTONE-adjustment 
: ±30

VERT. CURVED ARC

CVAV

43h  56h  41h  56h

±50
With KEYSTONE- or 
CORNERSTONE-adjustment 
: ±30

HORIZ. CURVED ORIGIN (vertical)

CVHOV

43h  56h  48h  4Fh  56h

±10

HORIZ. CURVED ORIGIN 
(horizontal)

CVHOH

43h  56h  48h  4Fh  48h

±10

VERT. CURVED ORIGIN (vertical)

CVVOV

43h  56h  56h  4Fh  56h

±10

VERT. CURVED ORIGIN (horizontal)

CVVOH

43h  56h  56h  4Fh  48h

±10

CURVED reset

CVRST

43h  56h  52h  53h  54h

BRIGHT UNIFORMITY 

CORRECTION (level)

BUCL

42h  55h  43h  4Ch

50 to 100
(Changeable in five increments)

BRIGHT UNIFORMITY 

CORRECTION (correcting position) 
(vertical)

BUCV

42h  55h  43h  56h

1 to 7

BRIGHT UNIFORMITY 

CORRECTION (correcting position) 

(horizontal)

BUCH

42h  55h  43h  48h

1 to 7

How to set the value

Use the character or ASCII code as shown below to set the value.

Character

+

-

0

1

2

3

4

5

6

7

8

9

ASCII code

‘2Bh’

‘2Dh’ ‘30h’ ‘31h’ ‘32h’ ‘33h’ ‘34h’ ‘35h’ ‘36h’ ‘37h’ ‘38h’ ‘39h’

4.5  Function commands

 (Not executable in stand-by mode. When the mute commands are sent while the splash 

screen is being displayed, the splash screen is only canceled.)

The BLANK command is used for the BLANK setting of this projector with the 0 (HEX: 30h) and 1 (HEX: 31h).

ITEM

Function

Data

Character

ASCII code

BLANK

MUTE

4Dh  55h  54h  45h

0 (OFF), 1 (ON)

SPLIT

SPLT

53h  50h  4Ch  54h

0 (OFF), 1 (ON)

MAGNIFY

MGNFY

4Dh  47h  4Eh  46h  59h

0 (OFF), 1 (ON)

FREEZE

FRZ

46h  52h  5Ah

0 (OFF), 1 (ON)

Function canceling

FNCOFF

46h  4Eh  43h  4Fh  46h  46h

Содержание WD8200U

Страница 1: ...trolling the projector using a personal computer for FL7000U ITEM Function Data Character ASCII code Changing the RS 232C command system COMMAND 43h 4Fh 4Dh 4Dh 41h 4Eh 44h 0 Former command system 1 New command system Connection Important Make sure that your computer and projector are turned off before connection Boot up the computer first and then plug the power cord of the projector If you do no...

Страница 2: ...o ID code is sent all the projectors return response When the projectors are connected in a daisy chain configuration you are recommended to set the PROJECTOR ID to other than ALL and assign the PROJECTOR ID differently for each projector to communicate with each projector individually Refer to the operation manual of the projector for setting the PROJECTOR ID When you use a daisy chain configurat...

Страница 3: ...in one second at the latest When the received command cannot be executed NAK is returned as described below 4 The return command input from the SERIAL OUT terminal is sent to the device connected to the SERIAL IN terminal The personal computer receives the commands as many as the number of the projectors that send the returned commands However the receiving order of the returned commands may vary ...

Страница 4: ...mand for POWER ON is sent to the projector with the ID of 01 or ALL 30 30 3B 30 31 3B 21 0D 00 01 The projector with the ID of 01 or ALL receives the command The status is echoed back from the projector with the ID of 01 or ALL Example 2 Selecting VIDEO as the input signal during auto positioning Values enclosed in quotation marks are ASCII codes When ID is not specified Command sent from the PC S...

Страница 5: ...s correct Check that the data code is correct Check that the projector is able to issue the return command Check the projector s operation using the 00vST command Note In the following cases NAK is returned even when the projector is in normal condition Immediately after the power is turned on about 20 seconds to 2 minutes During input switching During auto positioning During password lock Check t...

Страница 6: ... the input signal to COMPUTER 1 Values enclosed in quotation marks are ASCII codes When ID is not specified Command sent from the PC etc Status code returned from the projector Description 30 30 5F 72 31 0D 00_r1 Command for setting the input signal to COMPUTER 1 ID command is omitted 30 30 5F 72 31 0D 00_r1 Command receipt confirmation The statuses are echoed back as many as the number of the con...

Страница 7: ... 44h 4Ch within 16 characters Contact control vRMT 76h 52h 4Dh 54h 0 Normal operation 1 Contact control Input source vSOUCE 76h 53h 4Fh 55h 43h 45h r1 r2 v1 v2 d1 d2 Projector status vST 76h 53h 54h 0 Stand by mode 1 Within 1 minute after POWER ON warm up mode 2 POWER ON mode including state of warning 3 Cooling mode 4 Abnormal state including shutdown due to an error 5 State of functioning menu d...

Страница 8: ...9 72h 30h 39h FREEZE ra4 72h 61h 34h ASPECT re2 72h 65h 32h CE re7 72h 65h 37h TEST PATTERN r50 72h 35h 30h SUPER RESOLUTION r96 72h 39h 36h 1 numeric keypad r49 72h 34h 39h 2 numeric keypad r4a 72h 34h 61h 3 numeric keypad r4b 72h 34h 62h 4 numeric keypad r4c 72h 34h 63h 5 numeric keypad r4d 72h 34h 64h 6 numeric keypad r4e 72h 34h 65h 7 numeric keypad r88 72h 38h 38h 8 numeric keypad r58 72h 35h...

Страница 9: ...h 50 With KEYSTONE or CORNERSTONE adjustment 30 VERT CURVED ARC CVAV 43h 56h 41h 56h 50 With KEYSTONE or CORNERSTONE adjustment 30 HORIZ CURVED ORIGIN vertical CVHOV 43h 56h 48h 4Fh 56h 10 HORIZ CURVED ORIGIN horizontal CVHOH 43h 56h 48h 4Fh 48h 10 VERT CURVED ORIGIN vertical CVVOV 43h 56h 56h 4Fh 56h 10 VERT CURVED ORIGIN horizontal CVVOH 43h 56h 56h 4Fh 48h 10 CURVED reset CVRST 43h 56h 52h 53h ...

Страница 10: ... G B MRGB 4Dh 52h 47h 42h 30 30 30 R G B NCM Y C M MYCM 4Dh 59h 43h 4Dh 30 30 30 Y C M NCM SATURATION MSAT 4Dh 53h 41h 54h 05 NCM RGB TINT MT 4Dh 54h 15 COLOR TEMP A 41h 1 STANDARD 2 HIGH 3 LOW 4 USER COLOR TEMP USER CONTRAST P 50h 30 30 30 R G B COLOR TEMP USER BRIGHTNESS Q 51h 30 30 30 R G B COLOR T 54h 10 TINT S 53h 10 SHARPNESS R 52h 05 NOISE REDUCTION NR 4Eh 52h 0 OFF 1 ON CTI CTI 43h 54h 49h...

Страница 11: ...ER 2 3 VIDEO 4 S VIDEO 5 DVI 6 HDMI REMOTE 1 MODE PIN 7 R1M7P 52h 31h 4Dh 37h 50h 0 NONE 1 COMPUTER 1 2 COMPUTER 2 3 VIDEO 4 S VIDEO 5 DVI 6 HDMI REMOTE 1 MODE PIN 8 R1M8P 52h 31h 4Dh 38h 50h 0 NONE 1 BLANK REMOTE 1 MODE RESET R1MRST 52h 31h 4Dh 52h 53h 54h FILTER MENU CLEANUP PERIOD FLCP 46h 4Ch 43h 50h xdhh x Cleanup interval 0 OFF 1 24H 2 1WEEK dhh Next cleanup time d days hh hours OFF Fixed to...

Страница 12: ...R RED G GREEN B BLUE W WHITE COLOR MATCHING MEASURE MEASURED DATA x MSMX 4Dh 53h 4Dh 58h x to x Color selection R RED G GREEN B BLUE W WHITE The range varies depending on x COLOR MATCHING MEASURE MEASURED DATA y MSMY 4Dh 53h 4Dh 59h x to x Color selection R RED G GREEN B BLUE W WHITE The range varies depending on x COLOR MATCHING MEASURE TARGET DATA GAIN MSTG 4Dh 53h 54h 47h x020 to 100 x Color se...

Страница 13: ...TER TIME RESET TRSTFL 54h 52h 53h 54h 46h 4Ch RESET ALL RSTALL 52h 53h 54h 41h 4Ch 4Ch MEMORY CALL MMC 4Dh 4Dh 43h 0 AUTO 1 MEMORY1 2 MEMORY2 HORIZ POSITION HP 48h 50h increment decrement 1 VERT POSITION VP 56h 50h increment decrement 1 FINE SYNC FN 46h 4Eh 00 31 TRACKING TRK 54h 52h 4Bh increment decrement 1 COMPUTER INPUT CIN 43h 49h 4Eh 0 RGB 1 YCBCR YPBPR 2 AUTO OVER SCAN VOS 56h 4Fh 53h 00 90...

Страница 14: ...F 4E 31 0D 00 01 APON1 Command receipt confirmation The status is echoed back from the projector with the ID of 01 or ALL Example 2 When setting the CONTRAST R of the COLOR TEMP USER to 10 the CONTRAST G to 0 and the CONTRAST B to 5 Values enclosed in quotation marks are ASCII codes When ID is not specified Command sent from the PC etc Status code returned from the projector Description 30 30 50 2...

Страница 15: ...e projector with the ID of 01 or ALL Example 4 When setting the GAMMA MODE of the COLOR ENHANCER USER to DETAIL Values enclosed in quotation marks are ASCII codes When ID is not specified Command sent from the PC etc Status code returned from the projector Description 30 30 43 45 55 31 47 53 32 0D 00CEU1GS2 Command for setting the picture control ID command is omitted 30 30 43 45 55 31 47 53 32 0D...

Страница 16: ... the password lock of DISPLAY INPUT in the case that the password is 123412 Values enclosed in quotation marks are ASCII codes When ID is not specified Command sent from the PC etc Status code returned from the projector Description 30 30 50 53 4C 4F 43 4B 31 31 32 33 34 31 32 0D 00PSLOCK1123412 Command for enabling the password lock of DISPLAY INPUT ID command is omitted 30 30 50 53 4C 4F 43 4B 3...

Страница 17: ...s 12345678ABCD character string in ASCII code Run MD5 hash on the key of the certification data Create the certification data by converting the hash calculated 16 byte data into the ASCII code char acter string Example Calculation result 4f 3c 5d a1 7b 4f b5 ed 2c 99 4e bb f6 57 67 54 hexadecimal numeral Certification data 4f 3c 5d a1 7b 4f b5 ed 2c 99 4e bb f6 57 67 54 character string in ASCII c...

Отзывы: