Level 2 Service Manual
ARIA
Mitsubishi Electric Telecom Europe
Version C
ZA le Piquet, 35370 Etrelles
Date: 05/00
Phone: +33 2 99 75 71 00
Fax: +33 2 99 75 71 47
9/20
4.c
Operating instructions
1.
Insert Test SIM in the mobile
2.
Connect a charged battery
3.
Make a call with a RADIOCOMMUNICATION TESTER and check the following parameters,
or uses the autotest (CMD55 or CMD55 under MTS or Wavetek 4107)
Power levels :
check the transmitted power (dBm)
E-GSM 900
PCL
Power Level
(dBm)
tolerance
DCS 1800
PCL
Power level
(dBm)
tolerance
5
33
+/-2dB
0
30
+/-2dB
6
31
+/-3dB
1
28
+/-3dB
7
29
+/-3dB
2
26
+/-3dB
8
27
+/-3dB
3
24
+/-3dB
9
25
+/-3dB
4
22
+/-3dB
10
23
+/-3dB
5
20
+/-3dB
11
21
+/-3dB
6
18
+/-3dB
12
19
+/-3dB
7
16
+/-3dB
13
17
+/-3dB
8
14
+/-3dB
14
15
+/-3dB
9
12
+/-4dB
15
13
+/-3dB
10
10
+/-4dB
16
11
+/-5dB
11
8
+/-4dB
17
9
+/-5dB
12
6
+/-4dB
18
7
+/-5dB
13
4
+/-4dB
19
5
+/-5dB
14
2
+/-5dB
15
0
+/-5dB
RF Cable NN 50 OHMS 0.8
(FT7Y005610)
NSMA ADAPTATOR FEMALE
(FT7Y010010)
ARIA RF CABLE L300
(FT7Y010410)
Mobile with full
battery
RADIOCOMMUNICATION TESTER
Содержание trium aria
Страница 3: ......