3. Installation diagram

4.1. Accessories

Check the following parts before installation.

<Outdoor unit>

1

Drain socket (for VA type only)

1

3

Drain cap ø33 (for SUZ-KA50/KA60/KA71 only)

2

• Provide drain piping before indoor and outdoor piping connection. (It will be hard to

install drain socket 

1

 if indoor and outdoor piping connection is conducted prior to

drain piping as outdoor unit becomes immovable.)

• Connect the drain hose 

3

 (obtainable at a store, inside diameter: 15 mm) as shown

in the figure for drainage.

• Make sure to provide drain piping with a downhill grade for easy drain flow.

Note:
Do not use the drain socket 

1

 in the cold region. Drain may freeze and it makes

the fan stop.

Fig. 3-1

SUZ-KA25/KA35VA

Fig. 4-1

A

C

A

C

B

3.1. Outdoor unit (Fig. 3-1)

Ventilation and service space

SUZ-KA25/KA35VA

A

100 mm or more

B

350 mm or more

C

Basically open 100 mm or more without any obstruction in front and on both sides of the unit.

D

200 mm or more (Open two sides of left, right, or rear side.)

 SUZ-KA50/KA60/KA71VA

A

100 mm or more

B

350 mm or more

C

500 mm or more

When the piping is to be attached to a wall containing metals (tin plated) or metal
netting, use a chemically treated wooden piece 20 mm or thicker between the wall
and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.

Units should be installed by licensed contractor accordingly to local code require-
ment.

Note:
When operating the air conditioner in low outside temperature, be sure to fol-
low the instructions described below.

• Never install the outdoor unit in a place where its air inlet/outlet side may be ex-

posed directly to wind.

• To prevent exposure to wind, install the outdoor unit with its air inlet side facing the

wall.

• To prevent exposure to wind, it is recommended to install a baffle board on the air

outlet side of the outdoor unit.

SUZ-KA50/KA60/KA71VA

A

D

C

A

B

(mm)

4. Drain piping for outdoor unit (Fig. 4-1)

Air outlet

2-10 mm 

×

 21 mm slot

Air inlet

285 mm

40 mm

344.5 mm

304 - 325 mm

800 mm

500 mm

150

mm

Drain hose 

3

Drain socket 

1

(For VA type only)

Air out

40

330

Air in

66

299

515

34

(ø33)

Drainage 3 holes

51

Air in

360

500

SUZ-KA25/35VA

Содержание SUZ-KA71VA2

Страница 1: ...ners SUZ KA25 KA35 KA50 KA60 KA71VA English INSTALLATION MANUAL For safe and correct use read this manual and the indoor unit installation manual thoroughly before installing the air conditioner unit FOR INSTALLER ...

Страница 2: ...ld result in a fire or an electric shock Attach the electrical part cover to the indoor unit and the service panel to the outdoor unit securely If the electrical part cover in the indoor unit and or the service panel in the outdoor unit are not attached securely it could result in a fire or an electric shock due to dust water etc Be sure to use the part provided or specified parts for the installa...

Страница 3: ... right or rear side SUZ KA50 KA60 KA71VA A 100 mm or more B 350 mm or more C 500 mm or more When the piping is to be attached to a wall containing metals tin plated or metal netting use a chemically treated wooden piece 20 mm or thicker between the wall and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping Units should be installed by licensed contractor accordingly to loc...

Страница 4: ... 12 m max of 10 SUZ KA50 KA60 KA71 max 30 m max 30 m 15 m max of 10 MFZ Height difference limitations are binding regardless of which unit indoor or outdoor is positioned higher Refrigerant adjustment If pipe length exceeds 7 m additional refrigerant R410A charge is required The outdoor unit is charged with refrigerant for pipe length up to 7 m Up to 7 m No additional charge is required Pipe lengt...

Страница 5: ...d gas pipes between the indoor and the outdoor units Remove the service port cap of the stop valve on the side of the outdoor unit gas pipe The stop valve will not work in its initial state fresh out of the factory totally closed with cap on Connect the gage manifold valve and the vacuum pump to the service port of the stop valve on the gas pipe side of the outdoor unit Run the vacuum pump Vacuumi...

Страница 6: ...ed main switch fuse D Grounding For Power supply Connect cable from the indoor unit correctly on the terminal block Use the same terminal block and polarity as is used with the indoor unit For aftercare maintenance give extra length to connecting cable Both end of connecting cable extension wire are peeled off When too long or connected by cutting off the middle peel off power supply cable to the ...

Страница 7: ...1 S2 S3 S1 S2 S3 Warning There is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power line and communication signal line Therefore please turn off the main power supply when servicing And do not touch the S1 S2 S3 terminals when the power is energized If isolator should be used between indoor unit and outdoor unit please use...

Страница 8: ...e be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN BG79U686K01 Printed in Thailand ...

Отзывы: