15
15
REFRIGERANT SYSTEM DIAGRAM
8
Unit: mm
SUY-SA18VA.TH-T
Unit: mm
SUY-SA24VA.TH-T
SUY-SA30VA.TH-T
Flared connection
Discharge
temperature
thermistor
(RT62)
Flared connection
Stop valve(L)
(with strainer(#100))
Stop valve(G)
(with service port)
Refrigerant flow in cooling
Compressor
Refrigerant pipe ø12.7 (1/2")
Refrigerant pipe ø6.35 (1/4")
Strainer
#50
Strainer
#100
Strainer
#50×2
Liquid pipe
temperature
thermistor
(RT61)
Capillary tube
ø3.0×ø1.8×600(×2)
Outdoor heat
exchanger
temperature
thermistor
(RT68)
Muffler
Outdoor
heat
exchanger
LEV
Capillary tube
ø4.0×ø2.4×240
Flared connection
Discharge
temperature
thermistor
(RT62)
Flared connection
Stop valve(L)
Stop valve(G)
(with service port)
Refrigerant flow in cooling
Compressor
Refrigerant pipe ø15.88 (5/8")
Refrigerant pipe ø9.52 (3/8")
Strainer
#50
Strainer
#100
Strainer
#100
Capillary tube
ø4.0×ø2.4×100
Outdoor heat
exchanger
temperature
thermistor
(RT68)
Muffler(#100)
Outdoor
heat
exchanger
LEV
Liquid pipe
temperature
thermistor
(RT61)
OCH649