Before installing the unit, make sure you read all the “Safety   

precautions”.

        The “Safety precautions” provide very important points      

        

        regarding safety. Make sure you follow them. 

 

Symbols used in the text  

    Warning:

        This symbol denotes what could lead to serious injury or  

        death if you misuse the SPTB1 

    

Caution:

        This symbol denotes what could lead to a personal injury or    

        property damage if SPTB1 is misused

 Warning:

• 

Ask your technical representative to install the unit. 

Any deficiency caused by your own installation may 

result in electric shock or fire. 

• 

Ensure that installation work is done correctly following 

this instruction manual. Any deficiency caused by 

installation may result in electric shock or fire. 

• 

Firmly connect the wiring using the specified cables. 

Carefully check that the cables do not exert any forces 

on the terminals. Improper wiring connections may 

produce heat and possibly fire. 

• 

Never modify or repair the SPTB1. Any deficiency 

caused by your modification or repair may result in 

electric shock or fire. Consult with your technical 

representative about repair. 

• 

All electrical work must be performed by a licensed 

technician, according to the local regulations and the 

instructions given in this manual. Any lack of electric 

circuit or any deficiency caused by installation may 

result in electric shock or fire. 

• 

Stop the operation if any malfunction occurs. If 

malfunction occurs (burning smell, etc.) stop the 

operation and turn off the power supply. Contact your 

technical representative. If the controller continues 

to operate after a malfunction occurs, this may cause 

damage, electric shock or fire. 

• 

Do not turn on the main power until installation has 

been completed. Doing so may result in electric shock 

or fire. 

• 

Keep the area around the unit clean to keep the indoor 

unit from accumulating dust on the components. Dust 

particles that enter the indoor unit may cause fire. 

• 

Do not move and re-install the SPTB1 yourself. Any 

deficiency caused by the installation may result in 

electric shock or fire. Ask your distributor or special 

technical representative for moving and installation. 

 

 Caution:

• 

Do not install in any place exposed to flammable gas 

leakage. Flammable gases that accumulate around the 

SPTB1 may cause an explosion. 

• 

Do not use in any special environment. Using in any 

place exposed to oil (including machining oil), steam 

and sulfuric gas may deteriorate the performance 

significantly or give damage to the component parts. 

• 

Do not install in any place at a temperature of more 

than 104

o

 F or less than 32

o

 F or exposed to direct 

sunlight. 

• 

Do not install in any place where acidic or alkaline 

solution or special spays are often used. Doing so may 

cause an electric shock or malfunction. 

• 

Wire so that it does not receive any tension. Tension 

may cause wire breakage, heating or fire. 

• 

Do not install in an environment where moisture is 

condensed into water. Doing so may cause electric 

shock or malfunction. 

• 

Do not wash with water. Doing so may cause electric 

shock or malfunction. 

1. Safety Precautions

This manual describes the installation of the SPTB1 Separate 

Power Terminal Block for Mitsubishi Electric M&P series air 

conditioners.  The SPTB1 will allow for a separate power supply to 

the indoor unit rather than receiving power from the outdoor unit.  

Please refer to SPTB1 product guide for proper application.

Note:

        The installer will still need to run S2 and S3 wires from the 

outdoor unit to the indoor unit.  See Wiring Schematic section of this 

installation manual.

   

Caution:

        Do not power the electric heat package from the outdoor unit.

Содержание SPTB1

Страница 1: ...ITSUBISHI ELECTRIC US INC SPTB1 INSTALLATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit English FOR INSTALLER Separate Power Terminal Block Kit ...

Страница 2: ...2 Specifications are subject to change without notice 2015 Mitsubishi Electric US Inc Contents 1 Safety Precautions 3 2 Parts List 4 3 Installation 5 4 Wiring Schematic 7 ...

Страница 3: ... power until installation has been completed Doing so may result in electric shock or fire Keep the area around the unit clean to keep the indoor unit from accumulating dust on the components Dust particles that enter the indoor unit may cause fire Do not move and re install the SPTB1 yourself Any deficiency caused by the installation may result in electric shock or fire Ask your distributor or sp...

Страница 4: ...15 Mitsubishi Electric US Inc 2 Parts List A 1 Terminal Block labeled L1 and L2 B 1 M4 self drilling screw C 1 Wiring harness for communication brown and yellow wires with connector D 1 Wiring harness for power red blue and green wires with connector C D A B ...

Страница 5: ...below and remove the ELECTRICAL panel Step 2 Remove the 1 screw that secures the panel to the air handler Step 3 Control box for M P series air handler Step 4 Remove the screw that secures the green wire to the sheetmetal ground Step 5 Remove the harness beginning at the red plug CND next S1 S2 S3 and CN3C Step 6 Remove the harness from the air handler and discard If the model has a ferrite bead r...

Страница 6: ... with the provided M4 screw be tween the two terminal blocks in the control box There is already a pilot hole for the M4 screw in the control box Step 10 Plug the connector from the Power Wiring Harness into CND Connect the ground to the screw removed earlier and then connect the blue wire to L1 and the red to L2 NOTE If a ferrite bead was removed from the original wiring harness from the air hand...

Страница 7: ...7 2015 Mitsubishi Electric US Inc Specifications are subject to change without notice 4 Wiring Schematic ...

Страница 8: ...tions June 2015 Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential and light industrial environment 1340 Satellite Boulevard Suwanee GA 30024 Toll Free 800 433 4822 www mehvac com Manufactured for MITSUBISHI ELECTRIC US INC ...

Отзывы: