background image

Air-Conditioners

SEZ-KD25,KD35,KD50,KD60,KD71VAL

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

FOR USER

English

BEDIENUNGSHANDBUCH

Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.

MANUEL D’UTILISATION

Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du
climatiseur.

E°XEIPI¢IO O¢H°IøN XPH™Eø™

°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ ÛÂ
ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.

MANUAL DE INSTRUCCIONES

Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.

BEDIENINGSHANDLEIDING

Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.

ISTRUZIONI DI FUNZIONAMENTO

Leggere attentamente questi istruzioni di funzionamento prima di avviare l’unità, per un uso corretto e sicuro
della stessa.

DRIFTSMANUAL

Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.

DRIFTSMANUAL

Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.

MANUAL DE OPERAÇÃO

Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в
данном руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.

‹fiLETME ELK‹TABI

Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu
elkitab›n› dikkatle okuyunuz.

FÜR BENUTZER

POUR L’UTILISATEUR

°π∞ ∆√¡ Ã∏™∆∏

PARA EL USUARIO

VOOR DE GEBRUIKER

PER L’UTENTE

TIL BRUGER

PARA O UTILIZADOR

FÖR ANVÄNDAREN

ДЛЯ ПОЛЬЗОВАТЕЛЯ

KULLANICI ‹Ç‹N

Deutsch

Français

Español

Italiano

Nederlands

Svenska

Dansk

Português

∂ÏÏËÓÈο

Русский

Türkçe

KB79H174H04_cover.pm6

08.6.26, 10:15 AM

1

Содержание SEZ-KD25

Страница 1: ...I FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug MANUAL DE OPERAÇÃO Para seguranç...

Страница 2: ...cleaning indication Symbols used in the text Warning Describes precautions that should be observed to prevent danger of injury or death to the user Caution Describes precautions that should be observed to prevent damage to the unit Symbols used in the illustrations Indicates a part which must be grounded Warning The unit must not be installed by the user Ask the dealer or an authorized company to ...

Страница 3: ... high humidity To avoid misplacing the remote controller install the holder included with the remote con troller on a wall and be sure to always place the remote controller in the holder after use Battery installation replacement 1 Remove the top cover insert two AAA batter ies and then install the top cover Top cover 2 Press the Reset button CLOCK CHECK RESET SET TESTRUN MODE FAN VANE LOUVER min ...

Страница 4: ...ioner Outdoor unit MXZ series s s s s sMulti system air conditioner Outdoor unit MXZ series can con nect two or more indoor units with one outdoor unit According to the capacity two or more units can operate simultaneously When you try to operate two or more indoor units with one outdoor unit simultaneously one for the cooling and the other for heating the opera tion mode of the indoor unit that o...

Страница 5: ...at ing 2 Emergency operation In cases where the remote control unit does not operate properly use either the COOL or HEAT button on the wireless remote control signal receiver to toggle the unit on or off On cooler only units pushing the HEAT button toggles the fan on and off Pressing the COOL or HEAT button selects the following settings Operation mode COOL HEAT Preset temperature 24 C 75 F 24 C ...

Страница 6: ...button is pressed Air conditioner operates without the ON OFF button being pressed Here is the solution Unit is operating normally Clean the filter Airflow is reduced when the filter is dirty or clogged Check the temperature adjustment and adjust the set temperature Make sure that there is plenty of space around the outdoor unit Is the indoor unit air intake or outlet blocked Has a door or window ...

Страница 7: ...on has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off the power switch immediately and consult your dealer Be sure to provide the dealer with the model name High sound absorbing rooms Broadcasting studio music room etc 3 to 7 dB Normal rooms Reception room hotel lobby etc 6 to 10 dB Low sound absorbing rooms Office hotel room 9 to 13 dB Locatio...

Страница 8: ...is provided to avoid misplacing the remote controller Install the remote controller in a location that meets the following conditions Out of the direct sun light Away from any heat sources Out of the airflow from the air conditioner cool or warm Where the operation of the remote controller can easily be performed and the display is readily visible to the user Out of the reach of small children NOT...

Страница 9: ... should be installed by licensed electric contractor accordingly to local code requirement SEZ KD35VAL 0 05 0 46 7 9 11 5 15 35 50 23 28 33 200 990 700 21 SEZ KD71VAL 0 10 0 84 12 16 20 5 15 35 50 30 35 40 200 1190 700 27 Model Power supply Input Indoor only kW Current Indoor only A Airflow Lo Mid Hi CMM Ext static pressure Pa Noise level Lo Mid Hi dB Dimension H W D mm Weight kg SEZ KD50VAL 0 07 ...

Страница 10: ...e 2006 95 EC Electromagnetic Compatibility Directive 89 336 EEC 2004 108 EC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN KB79H174H04 The product at hand is based on the following EU regulations ...

Отзывы: