Содержание RG79F146H03

Страница 1: ...to its disposal location Secure 2 zone kit to prevent it from falling Do not hold piping or drain socket when moving the 2 zone kit Avoid the connection of piping or drain socket from damage Otherwise it may cause water leakage To prevent incorrect installation please connect the flexible hose at the bend radius of 150 mm or more The water flow rate between the Cylinder unit Hydrobox and the 2 zon...

Страница 2: ...ontains a heavy metal at a certain concentration This is indicated as follows Hg mercury 0 0005 Cd cadmium 0 002 Pb lead 0 004 In the European Union there are separate collection systems for used electrical and electronic products batteries and accumulators Please dispose of this equipment batteries and accumulators correctly at your local community waste collection recy cling centre Contact your ...

Страница 3: ...2000 2100 1220 1270 Cylinder unit Hydrobox 2 zone kit Zone1 Radiator Zone2 Floor heating Pump3 THW6 THW7 THW8 Pump2 THW9 Air vent Air vent Mixing valve 3 Unit mm Pump3 Pump2 Mixing valve Thermistor Manual air vent Cylinder unit Hydrobox Reactor box Thermistor Earth terminal RG79F146H03_en indd 3 2020 04 16 13 55 30 003 ...

Страница 4: ...e hose below the bend radius of 150 mm After hand tighten the nut tighten the joint 1 turn If necessary tighten by another 1 4 of a turn Pipe cover Local supply Ensure that the 2 zone kit does not touch the pressure relief valve Remove the screw from the 2 zone kit and reuse to secure RG79F146H03_en indd 4 2020 04 16 13 55 32 004 ...

Страница 5: ...at are round or oval To prevent the 2 zone kit from falling off the wall choose the appropriate number of holes or hole positions and horizontally secure the back plate to the appropriate wall location Plugs Local supply Wall Screws Local supply Back plate Horizontal Side view 1 5N m Back plate Remove the back plate from the top of the 2 zone kit Install the included back plate accessory RG79F146H...

Страница 6: ... of 20 mm Field supplied drain pipe VP 20A Insulated Connect drain socket to field pipeworks using suitable adhesive bond Connect the drain pipe only for Heating Cooling models Cylinder unit Hydrobox Field supplied drain pipe VP 20A Insulated Connect drain socket to field pipeworks using suitable adhesive bond Pipe cover Local supply Tightening torque 42N m Use double spanners Do not use the flexi...

Страница 7: ...7 5 4 3 2 1 TBI 3 6 8 7 5 4 3 2 1 TBI 4 6 8 7 5 4 3 2 1 TBI 5 6 8 7 5 4 3 2 1 6 8 7 5 4 3 2 1 TBI 6 1 4 CN401 WH 7 2 CN22 CN108 CN01 BK 1 3 CN3C BU CNPWM WH 1 8 CN851 BK 1 5 CNRF WH CN105 RD CNIT BU 1 2 CN20 RD TBI 1 LED3 LED4 TAB1 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 CNP1 WH TBO 1 1 5 3 1 5 SW6 1 3 1 5 1 5 BU 1 LED2 1 SW1 8 1 SW2 8 1 SW3 1 SW4 6 8 1 SW5 LED1 1 3 1 3 CNP4 RD TBO 2 1 2 3 4 5 6 TBO 3 CNV1 ...

Страница 8: ... key lock function Model name PAC TZ02 E Dimension 265mm 383mm 383mm Weight 17kg Power supply 230V single phase 50Hz from Cylinder unit Hydrobox Sound pressure level 28dB A Sound power level 40dB A Pump2 3 Max 52W 0 52A Max head 7 0m 1 Mixing valve 5W Running time 90 120s Water flow rate range Depend on outdoor unit Note Max flow rate is 36 9L min If the flow rate exceeds 36 9L min pipes would be ...

Страница 9: ...e curve PP2 intermediate proportional pressure curve PP3 highest proportional pressure curve PP Auto Adapt highest to lowest proportional pressure curve The Auto Adapt function enables the circulator to adjust the pump performance automatically to the size of the system or the variations in load over time Mode LED1 green LED2 green LED3 yellow LED4 yellow LED5 yellow PP1 PP2 PP3 PP AA CP1 CP2 CP3 ...

Страница 10: ...o Adapt function enables the circulator to adjust the pump performance automatically to the size of the system or the variations in load over time The circulator runs on a constant curve Constant Pressure CP1 CP2 CP3 0 0 1 0 2 0 4 0 5 70 60 30 Flow rate L min 0 10 20 30 40 50 60 70 80 External static pressure kPa 0 10 20 30 40 50 60 70 80 0 0 1 0 2 0 4 0 5 60 External static pressure kPa 30 Flow r...

Страница 11: ...11 RG79F146H03_en indd 11 2020 04 16 13 55 40 011 ...

Страница 12: ...7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in the UNITED KINGDOM Please be sure to put the contact address telephone number on this manual before handing it to the customer RG79F146H03_en indd 12 2020 04 16 13 55 40 012 ...