10/13/04                                                                                             9                                                                                      93120-MAN07 

TERMINAL BLOC

KS

LABELS

6"

6"

.312"

Ø

 MOUN

H

O

LES

C

IRC

UIT BOA

R

D

BATTERY H

O

LDER

FIGURE 3.1

(IN

T

ERN

A

L POWER SU

PPLY

 /

 HARD

WIRE

 OPTION)

BATT

E

RY

ARRA

NGEMENT

11 RE

CTIFIE

R

15 LO

B

A

T

T

ERY

14 UP

S

 COMMON

13 UP

S

 FAILUR

E

17 O

V

E

R

LO

AD

18 O

V

E

R

LO

AD CO

MMO

N

16 

LO

W B

A

T

T

ERY

 COM

M

O

N

12 RE

CTIFIER COMMON

3 GROUND

7 I

N

VERTER

6 BY

PASS C

O

MMON

4 NO

US

E

D

9 ON

 BA

TTERIE

S

10 BATTE

RY COMM

ON

8 I

N

VERTER 

COMMON

5 BYPASS

2 AC

 NEUTR

A

INPUT

1 AC

 LI

NE INP

UT L1

Содержание REMOTE STATUS ALARM PANEL

Страница 1: ...W3 002 SLSUPS 002A REMOTE STATUS ALARM PANEL INSTALLATION INSTRUCTION MANUAL RSAP Mitsubishi Electric Automation Inc UPS Group ...

Страница 2: ...osed Hardwired Figure 1 1 5 Terminal Block Description Figure 2 0 6 Terminal Block Description Hardwired Figure 2 1 7 Remote Monitor Open Figure 3 0 8 Remote Monitor Open Hardwired Figure 3 1 9 Remote Monitor Conduit Access Figure 4 10 Figure 2033A Analog UPS 11 Figure 2033A DDC UPS 12 Figure 2033C UPS 13 Figure 2033D 9800AD UPS 14 Figure 9700 Series 15 Figure 9800A UPS 16 ...

Страница 3: ... 0 3 0 and the corresponding UPS wiring diagram connect the seven 7 pairs of twisted wire from the RSAP to the customer accessible alarm contact terminal bar in the UPS module Refer to the UPS owner s manual for location 6 Refering to Figure 3 0 install 6 AA batteries included Batteries will provide about 8 hours of run time in the event of an AC power failure Replace these batteries yearly for op...

Страница 4: ...ackup mode The audible alarm will beep intermittently 3 Inverter On LED The green LED is illuminated as long as the UPS inverter is operating 4 Output LED This green LED is illuminated as long as there is power to the critical load either by the Inverter or Bypass 5 Load On Bypass LED This yellow LED is illuminated as long as the critical load is powered by the Bypass 6 AC Input LED This green LED...

Страница 5: ...GE RED LED 11 ALARM SILENCE RED LED 12 INTERNAL MONITOR BATTERY OK YELLOW LED 5 LOAD ON BYPASS YELLOW LED 4 OUTPUT TO CRITICAL LOAD GREEN LED 3 INVERTER ON GREEN LED 2 BATTERIES ON YELLOW LED AUDIBLE ALARM MONITOR RESET PUSHBUTTON MONITOR TEST PUSHBUTTON ALARM SILENCE PUSHBUTTON INTERNAL MONITOR BATTERY TEST PUSHBUTTON INPUT TRANSFORMER FEMALE MIC PLUG 6 CORD FIGURE 1 0 INPUT CONFIGURATION SEE OPT...

Страница 6: ...LED 7 UPS FAULT RED LED 8 OVERLOAD RED LED 9 INPUT FAILURE RED LED 10 BATTERY LOW VOLTAGE RED LED 11 ALARM SILENCE RED LED 12 INTERNAL MONITOR BATTERY OK YELLOW LED 5 LOAD ON BYPASS YELLOW LED 4 OUTPUT TO CRITICAL LOAD GREEN LED 3 INVERTER ON GREEN LED 2 BATTERIES ON YELLOW LED AUDIBLE ALARM MONITOR RESET PUSHBUTTON MONITOR TEST PUSHBUTTON ALARM SILENCE PUSHBUTTON INTERNAL MONITOR BATTERY TEST PUS...

Страница 7: ...HEN ON BATTERIES BATTERY COMMON RECTIFIER CLOSES WHEN RECTIFIER IS RUNNING RECTIFIER COMMON UPS FAILURE CLOSES ON UPS FAILURE UPS COMMON LOW BATTERY CLOSES WHEN BATTERIES ARE LOW LOW BATTERY COMMON OVERLOAD CLOSES WHEN IN OVERLOAD OVERLOAD COMMON AC INPUT L1 OPTION 1 2 3 4 5 7 8 6 9 16 15 14 11 13 12 10 TB1 TERMINAL BLOCK DESCRIPTION LOCATED INSIDE BOX FIGURE 2 0 ...

Страница 8: ...CTIFIER IS RUNNING RECTIFIER COMMON UPS FAILURE CLOSES ON UPS FAILURE UPS COMMON LOW BATTERY CLOSES WHEN BATTERIES ARE LOW LOW BATTERY COMMON OVERLOAD CLOSES WHEN IN OVERLOAD OVERLOAD COMMON NOT USED 4 5 7 8 6 9 16 15 14 11 13 12 10 TERMINAL BLOCK DESCRIPTION LOCATED INSIDE BOX FIGURE 2 1 INTERNAL POWER SUPPLY HARDWIRE OPTION AC LINE INPUT L1 AC NEUTRAL INPUT GROUND 3 2 1 17 18 ...

Страница 9: ... BATTERY COMMON 9 RECTIFIER 10 RECTIFIER COMMON 11 UPS FAILURE 12 UPS COMMON 13 LOW BATTERY 14 LOW BATTERY COMMON 15 OVERLOAD 16 OVERLOAD COMMON 1 AC INPUT L1 OPTION BATTERY ARRANGEMENT TERMINAL BLOCK LABELS 6 6 312 Ø MOUNT HOLES CIRCUIT BOARD BATTERY HOLDER INPUT PLUG INPUT TRANSFORMER 12 VOLT DC OUTPUT FIGURE 3 0 ...

Страница 10: ...WER SUPPLY HARDWIRE OPTION BATTERY ARRANGEMENT 11 RECTIFIER 15 LOW BATTERY 14 UPS COMMON 13 UPS FAILURE 17 OVERLOAD 18 OVERLOAD COMMON 16 LOW BATTERY COMMON 12 RECTIFIER COMMON 3 GROUND 7 INVERTER 6 BYPASS COMMON 4 NOT USED 9 ON BATTERIES 10 BATTERY COMMON 8 INVERTER COMMON 5 BYPASS 2 AC NEUTRAL INPUT 1 AC LINE INPUT L1 ...

Страница 11: ...ULT OVERLOAD INPUT FAILURE ALARM SILENCE INTERNAL MONITOR BATTERY TEST MONITOR RESET MONITOR TEST OUTPUT BYPASS INPUT 1 50 1 50 1 50 4 00 6 00 6 00 1 00 1 00 Ø 0 312 MOUNT HOLES KNOCKOUT FOR 1 2 EMT CONDUIT TYP TOP AND BOTTOM KNOCKOUT FOR 1 2 EMT CONDUIT REAR VIEW FRONT VIEW TOP VIEW FIGURE 4 ...

Страница 12: ...ble Item 3 Rectifier On Battery Operation Selectable Item 4 On Batteries Load on Inverter Selectable Item 2 Load on Inverter Common Common Load on Bypass Selectable Item 1 Load on Bypass 02 15 00 Tom Kobayashi U 23026 1 1 Remote Status Alarm Panel RSAP Interconnect Diagram 2033 A Analog External Terminal Strip in UPS Terminal Strip TB1 in Remote Status Alarm Panel 16 awg twisted pair recommended N...

Страница 13: ...ailure UPS Failure Common Common Converter Operation Rectifier On Battery Operation On Batteries Load on Inverter Load on Inverter Common Common Common Common Load on Bypass Load on Bypass 03 10 98 Mario Recine U 23028 1 1 Remote Status Alarm Panel RSAP Interconnect Diagram 2033 A DDC External Terminal Strip in UPS Terminal Strip TB1 in Remote Status Alarm Panel 14 awg shielded wire recommended No...

Страница 14: ...ter Operation Common Rectifier On Common Converter Operation Rectifier On Battery Operation On Batteries Load on Inverter Common Load on Inverter Battery Operation Common On Batteries Common Load on Bypass Common Load on Bypass Common Load on Bypass Load on Bypass 02 15 00 Tom Kobayashi U 23C012 1 1 Remote Status Alarm Panel RSAP Interconnect Diagram 2033 C External Terminal Strip in UPS Terminal ...

Страница 15: ...mon Battery Operation Converter Rectifier Operation Load on Inverter Common Load on Inverter 8 29 03 Carl E Luecht U 23D019 1 1 Remote Status Alarm Panel RSAP Interconnect Diagram 2033D 9800AD External Terminal Strip TN1 Output in UPS Terminal Strip TB1 in Remote Status Alarm Panel 6 Load on Bypass Load on Bypass Common Bypass Common 16 15 14 13 12 11 10 9 8 7 6 5 Overload Common Overload Low Batt...

Страница 16: ...S Failure UPS Failure Common Common Converter Operation Rectifier On Battery Operation On Batteries Load on Inverter Load on Inverter Common Common Common Common Load on Bypass Load on Bypass 10 21 97 Mario Recine U 97017 1 1 Remote Status Alarm Panel RSAP Interconnect Diagram 9700 External Terminal Strip in UPS Terminal Strip TB1 in Remote Status Alarm Panel 14 awg shielded wire recommended Note ...

Страница 17: ...ation Rectifier Operation Load on Inverter Common Load on Inverter Common Load on Inverter 07 09 99 Mario Recine U 98015 1 1 Remote Status Alarm Panel RSAP Interconnect Diagram 9800A External Terminal Strip in UPS Terminal Strip TB1 in Remote Status Alarm Panel 18 17 Load on Bypass Load on Bypass Common Load on Bypass Common Load on Bypass 16 15 14 13 12 11 10 9 8 7 6 5 Output Overload Common Outp...

Отзывы: