2 SPECIFICATIONS
2.1 Performance Specifications
29
2
*1 Up to 64 settings can be configured by combining data logging, event logging, and report function.
Of these, up to 32 settings can be configured for data logging, event logging, and report function when high speed sampling is specified.
*2 For the output file format, refer to the following manual.
MELSEC iQ-R High Speed Data Logger Module User's Manual(Application)
*3 When a subfolder is not created in the save folder, the number of saved files is in the range of 1 to 256.
■
Restrictions on event logging
The restrictions on performance specifications of event logging are as follows.
Event logging
Saved folder name
■
Simple setting
• Add the name
• Add the date (4-digit year, month, day)
• Add the time (hour, minute, second)
• Add the sequential number
■
Detailed setting
• 4-digit year/2-digit year, month, day, day of the week, hour, minute, second
• Device value (two types)
• Sequential number
Item
High speed sampling
General sampling
Total number of event condition, period condition, file switching
condition, and folder switching condition
Up to combination of 5 conditions
Up to combination of 10 conditions
Event condition
Up to 4 conditions
Period condition
Up to 4 conditions
Up to 8 conditions
File switching condition
Up to 4 conditions
Up to 8 conditions
Folder switching condition
Up to 4 conditions
Up to 8 conditions
Item
Specifications
Содержание RD81DL96
Страница 2: ......
Страница 80: ...78 7 INSTALLATION AND UNINSTALLATION 7 2 Uninstallation Procedure MEMO ...
Страница 115: ...8 OPERATION EXAMPLE 8 3 Creating Reports from Continuously Logged Data 113 8 MEMO ...
Страница 117: ...APPX Appendix 1 External Dimensions 115 A MEMO ...
Страница 119: ...I 117 MEMO ...
Страница 123: ......