478
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
[Md.20] Current feed value
The currently commanded address is stored. (Different from the actual motor position during operation)
The current position address is stored.
If "degree" is selected as the unit, the addresses will have a ring structure for values between 0 and 359.99999
.
• The home position address is stored when the machine home position return is completed.
• When the current value is changed with the current value changing function, the changed value is stored.
Refresh cycle: Operation cycle
■
Reading the monitor value
• Monitoring is carried out with a hexadecimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.124] Control mode switching status
0
[Md.125] Servo status3
0000H
[Md.500] Servo status7
0000H
[Md.502] Driver operation alarm number
0000H
[Md.503] Pre-reading data analysis status
0
Item
Default value
Actual value
A
B
C
D
A
B
C
D
E
F
G
H
E
R
F
G
H
(High-order buffer memory) (Low-order buffer memory)
Low-order buffer memory
b15
b12
b4
b0
b8
E
F
G
H
High-order buffer memory
b31
b28
b20
b16
b24
A
B
C
D
[Md.20] Current feed value
[Md.21] Machine feed value
[Md.22] Feedrate
R
×
10
m
Unit conversion table ([Md.20][Md.21])
m
-1
μ
m
-5
inch
-5
degree
0
pulse
Unit
Unit conversion table ([Md.22])
m
-2
mm/min
-3
inch/min
-3
*
degree/min
0
pulse/s
Unit
Monitor value
Converted from
hexadecimal to decimal
Decimal integer
value
Unit conversion
Sorting
*: When "[Pr.83] Speed control
10
×
multiplier setting for
degree axis" is valid: "-2"
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......