390
12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
Monitor data
n: Axis No. - 1
p: Pointer No. - 1
Home
position
return
parameters
Home position
return detailed
parameters
[Pr.50]
Setting for the movement amount after near-point dog ON
80+150n
81+150n
[Pr.51]
Home position return acceleration time selection
82+150n
[Pr.52]
Home position return deceleration time selection
83+150n
[Pr.53]
Home position shift amount
84+150n
85+150n
[Pr.54]
Home position return torque limit value
86+150n
[Pr.55]
Operation setting for incompletion of home position return
87+150n
[Pr.56]
Speed designation during home position shift
88+150n
[Pr.57]
Dwell time during home position return retry
89+150n
Expansion parameter
[Pr.91]
Optional data monitor: Data type setting 1
100+150n
[Pr.92]
Optional data monitor: Data type setting 2
101+150n
[Pr.93]
Optional data monitor: Data type setting 3
102+150n
[Pr.94]
Optional data monitor: Data type setting 4
103+150n
Memory area
Item
Buffer memory address
System monitor data
[Md.3]
Start information
Start history
87010+10p
[Md.4]
Start No.
87011+10p
[Md.54]
Start (Year: month)
87012+10p
[Md.5]
Start (Day: hour)
87013+10p
[Md.6]
Start (Minute: second)
87014+10p
[Md.60]
Start (ms)
87015+10p
[Md.7]
Error judgment
87016+10p
[Md.8]
Start history pointer
87000
[Md.19]
Number of write accesses to flash ROM
4224
4225
[Md.50]
Forced stop input
4231
[Md.51]
Amplifier-less operation mode status
4232
[Md.52]
Communication between amplifiers axes searching flag
4234
[Md.53]
SSCNET control status
4233
[Md.59]
Module information
31332
[Md.130]
F/W version
4006
4007
[Md.131]
Digital oscilloscope running flag
4011
[Md.132]
Operation cycle setting
4238
[Md.133]
Operation cycle over flag
4239
[Md.134]
Operation time
4008
[Md.135]
Maximum operation time
4009
Axis monitor data
[Md.20]
Current feed value
2400+100n
2401+100n
[Md.21]
Machine feed value
2402+100n
2403+100n
[Md.22]
Feedrate
2404+100n
2405+100n
[Md.23]
Axis error No.
2406+100n
[Md.24]
Axis warning No.
2407+100n
[Md.25]
Valid M code
2408+100n
[Md.26]
Axis operation status
2409+100n
[Md.27]
Current speed
2410+100n
2411+100n
[Md.28]
Axis feedrate
2412+100n
2413+100n
Memory area
Item
Buffer memory address
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......