7.1 Program Example when GX Configurator-CT is Used
7.1.1 GX Configurator-CT operation
7
PROGRAMMING
7.1
Program Example when GX Configurator-CT is Used
7.1.1
GX Configurator-CT operation
(1) Initial setting (refer to Section 6.4.)
Figure 7.2 shows settings have to be made.
Figure 7.2 [Initial setting] screen
Table 7.5 Items on the [Initial setting] screen
Setting item
Description
Setting
Preset value setting
Set the preset value.
2500
Coincidence detection point
change request
Set this to enable the coincidence detection point setting.
Change
request
Coincidence detection point
setting
Set the value for coincidence detection point.
1000
Ring counter lower limit value
Set this only when using the ring counter function.
-5000
Ring counter upper limit value
Set this only when using the ring counter function.
5000
Period setting [unit: 10ms]
Set this only when using the periodic pulse counter function.
500